Archives: Shop
Showing 281–320 of 332 results
-
SPRINTER PTCA BALLOON
NC SPRINTER RX NONCOMPLIANT
BALLOON CATHETER
OVERVIEW
The NC Sprinter™ RX noncompliant coronary balloon combines:
- Sprinter crossing technology
- High-pressure capability and controlled expansion1
ORDERING INFORMATION
BALLOON LENGTHS 6, 9, 12 MM
ColumnsBalloon Diameter (mm)
Balloon Length (mm) 6 9 12 2.00 NCSP2006X NCSP2009X NCSP2012X 2.25 NCSP22506X — NCSP22512X 2.50 NCSP2506X NCSP2509X NCSP2512X 2.75 NCSP27506X NCSP27509X NCSP27512X 3.00 NCSP3006X NCSP3009X NCSP3012X 3.25 NCSP32506X NCSP32509X NCSP32512X 3.50 NCSP3506X NCSP3509X NCSP3512X 3.75 NCSP37506X NCSP37509X NCSP37512X BALLOON LENGTHS 15, 21, 27 MM
ColumnsBalloon Diameter (mm)
Balloon Length (mm) 15 21 27 2.00 NCSP2015X NCSP2021X — 2.25 — NCSP22521X — 2.50 NCSP2515X NCSP2521X NCSP2527X 2.75 NCSP27515X NCSP27521X — 3.00 NCSP3015X NCSP3021X NCSP3027X 3.25 NCSP32515X NCSP32521X — 3.50 NCSP3515X NCSP3521X NCSP3527X 3.75 NCSP37515X NCSP37521X — 4.00 NCSP4015X NCSP4021X NCSP4027X 4.50 NCSP4515X NCSP4521X — 5.00 NCSP5015X — — CROSSING PROFILE
Columns2.00 0.60 (0.024) 2.25 0.62 (0.024) 2.50 0.63 (0.025) 2.75 0.65 (0.025) 3.00 0.66 (0.026) 3.25 0.68 (0.027) 3.50 0.70 (0.027) 3.75 0.71 (0.028) 4.00 0.73 (0.029) 4.50 0.76 (0.030) 5.00 0.80 (0.032) -
Statlock
The StatLock PICC Plus Stabilization Device is a “post and door” design to house the suture wings of virtually all peripherally inserted central catheters(PICCs). Available in adult, pediatric and neonatal sizesStatLock stabilization devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies …Combining the latest in design and engineering technology, StatLock™ PICC Plus Stabilization Device releasably secures most winged–catheters on the market.The StatLock PICC Plus Catheter Stabilization Device holds winged PICC catheters in place for patient safety. This product has been shown in studies to greatly …Bard StatLock – PICC Plus Stabilization Device minimizes PICC catheter complications and maximizes comfort. This stabilizer eliminates the need to secure …Suture-Free” Stabilization for PICC Catheters. An Evidence-Based … Description. QTY/Box … StatLock® PICC II Device, Foam Anchor Pad, Fixed Posts.Statlock® stabilization device is a stabilization device for compatible winged catheters. PRECAUTIONS:.Product Overview. StatLock PICC Plus sutureless securement can secure PICC lines in place, eliminating the need for suture or tape and significantly reducing ..
-
SUCTION CANNULA
XCELL SUCTION CANNULA
The Suction Cannulas are intended for draining
the excess fluid from pericardial sac or the
cardiac chambers during cardiopulmonary
bypass surgery up to six hours.SUCTION CANNULA
Suction Cannula with
(or without) Stylet
Order No. Model Length (mm) Connector (inch)
SCA-12 Infant 310 1/4
SCA-14 Pediatric 335 1/4
SCA-18 Adult 370 1/4
VENT CANNULA: The product is intended to drain blood from
left atrium and left ventrical. -
SWAN-GANZ
SWAN-GANZ CATHETER
The FastCCO algorithm fuses the trusted performance of continuous thermodilution with the rapid response of arterial pressure-based cardiac output (APCO) to deliver CO and SV status every 20 seconds. Providing quicker flow insights than continuous thermodilution, the FastCCO algorithm enables faster feedback for more efficient clinical decision-making.
The Swan-Ganz catheterContinuous view of cardiac function in your most complex patients
The first flow-directed Swan-Ganz pulmonary artery catheter revolutionized haemodynamic monitoring in critically ill patients.1 By providing a comprehensive haemodynamic profile, utilising continuous data, Swan-Ganz pulmonary artery catheters track your patient’s haemodynamic status to assist your early evaluation.
The Swan-Ganz catheter, now with the FastCCO algorithm, enables CO and SV parameters every 20 seconds.
Target complex patient conditions with advanced haemodynamic parameters
The Swan-Ganz catheter with FastCCO algorithm allows continuous monitoring of the balance of oxygen delivery and consumption with these advanced haemodynamic parameters:
- Stroke volume (now SV20s with FastCCO algorithm)
- Cardiac output (now CO20s with FastCCO algorithm)
- Mixed venous oxygen saturation (SvO2)
- Systemic vascular resistance (SVR)
- Right ventricular ejection fraction (RVEF)
- Right ventricular end diastolic volume (RVEDV)
- Pulmonary artery pressure (PAP)
- Pulmonary artery occlusion pressure (PAOP)*
SvO2 mixed venous oxygen saturation
Swan-Ganz pulmonary artery catheters provide continuous monitoring of SvO2. Since SvO2 is a sensitive indicator of the patient’s status and generally precedes other indications of cardiopulmonary instability, continuous SvO2 monitoring may allow diagnostic and therapeutic decisions to be made earlier in the patient’s clinical course.
FastCCO algorithm for Swan-Ganz advanced technology cathetersTrusted performance, faster response
Swan-Ganz pulmonary artery catheters provide flow, pressure, and oxygen delivery and consumption parameters. With the FastCCO algorithm, CO and SV update every 20 seconds, giving you a faster, uninterrupted view of cardiac function for more proactive decision support in your most complex patients.
70% faster than current Swan-Ganz pulmonary artery catheter technologies
Fusing the trusted performance of continuous thermodilution with the rapid response of arterial pressure-based cardiac output (APCO), the FastCCO algorithm delivers continuous flow insights that enable you to quickly respond to transient changes in CO.
For cardiac surgical patients, the FastCCO algorithm can deliver cardiac output values quickly upon coming off of bypass during on-pump procedures.
Individualised fluid management
The FastCCO algorithm’s flow parameter readings every 20 seconds enable continuous observation of patient responses to fluid challenges and passive leg raise tests, and allow faster optimisation of fluid management.
The fluid responsiveness test screen on the HemoSphere advanced monitoring platform allows you to quickly assess preload responsiveness by tracking changes in SV, SVI, CO or CI in response to a fluid challenge.

Fluid responsiveness test screen on HemoSphere platform Comprehensive haemodynamic management
FastCCO algorithm is part of the latest software on HemoSphere advanced monitoring platform.
Also available for the modular HemoSphere platform is ForeSight tissue oximetry system, which continuously monitors oxygen saturation, noninvasively. The HemoSphere platform gives you a comprehensive view of tissue oximetry and advanced haemodynamics on one monitor so you can ensure your patient is adequately perfused.
Advanced technology catheter model numbers
Model Description Size (F) CO20s SV20s CCO SvO2 SV SVR RVEF RVEDV VIP port 774F75 CCOmbo RVEDV (CCO + SvO2 + RVEDV) 7.5 X X X X X X X X 777F8 CCOmbo RVEDV/VIP (CCO + SvO2 + RVEDV + VIP lumen) 8 X X X X X X X X X Thermodilution pulmonary artery catheters
The thermodilution catheters monitor intracardiac pressures, cardiac output, and provide infusing solutions.

When used with a compatible monitor, the following parameters are available through the thermodilution catheters: ICO, PAPs, PAOP
Assesses haemodynamic condition through direct intracardiac and pulmonary artery pressure monitoring, cardiac output determination and for infusing solutions†
The distal (pulmonary artery) port also allows sampling of mixed venous blood for the assessment of oxygen transport balance and the calculation of derived parameters such as oxygen consumption, oxygen utilization coefficient, and intrapulmonary shunt fraction
The Swan-Ganz VIP catheters have an extra lumen with proximal port (30 cm) for infusion in addition to the standard distal and injectate lumens to provide direct access to the right atrium
The Swan-Ganz VIP+ catheter has a right ventricular lumen that terminates 19 cm from the catheter tip and the right atrial lumen at 31 cm
Model numbers
Model Description Size (F) Length (cm) 132F5 Four Lumen Catheter 5 78 096F6P Four Lumen Catheter 6 110 131F7 Standard Four Lumen Catheter 7 110 Flow-directed monitoring catheters
The following parameters are available through the flow-directed monitoring catheters†: Pulmonary Artery Pressure (PAP), Pulmonary Artery Occlusion Pressure (PAOP)*.
The flow-directed monitoring catheters monitor right heart pressures and enable mixed venous blood sampling as well as infusing solutions.

Model numbers
Model Description Size (F) Length (cm) 110F5 Double Lumen Monitoring 5 110 111F7P Double Lumen Monitoring 7 110 123F6P Double Lumen Monitoring 6 110 114F7P Triple Lumen Monitoring 7 110 Bipolar pacing catheters
Bipolar pacing catheters are designed for temporary right ventricular endocardial pacing.‡
- Balloon tip facilitates insertion by flow-direction
- A pair of electrodes at the tip provide capabilities for bipolar pacing
- “J”- tip configuration is available for femoral insertion to predispose the catheter to a stable pacing position in the apex of the right ventricle


Model numbers
Model Description Size (F) Length (cm) D97120F5 SVC Insertion, Catheter Only 5 90 D97130F5 Femoral Insertion, Catheter Only, J-Tip 5 90 Thermodilution paceport catheter
The A-V Paceport or Pacing-TD catheters offer atrial, ventricular, or A-V sequential temporary transvenous pacing in the right heart.§
- The Thermodilution paceport catheter offers temporary transvenous right ventricular pacing‡ when used with the appropriate Edwards Chandler Transluminal V pacing probes
- The Thermodilution A-V paceport catheter is indicated for temporary transvenous right ventricular, atrial, or A-V sequential pacing‡ when used with the appropriate Edwards Chandler Transluminal A and/or V pacing probes
- Swan-Ganz oximetry paceport TD catheters offer bolus cardiac output and SvO2 monitoring when used with a compatible monitor in addition to temporary transvenous pacing when used with the appropriate Edwards Chandler Transluminal V pacing probe


Model numbers
Model Paceport Catheters and Chandler Probes Size (F) Length (cm) 931F75 Paceport 5 Lumen TD Catheter 7.5 110 Pacing-TD catheters
The A-V Paceport or Pacing-TD catheters offer atrial, ventricular, or A-V sequential temporary transvenous pacing in the right heart.§
- Three atrial and two ventricular electrodes for atrial and ventricular pacing and atrioventricular (A-V) sequential pacing are integrated into the pulmonary artery catheter for temporary transvenous pacing‡
- Pacing-TD catheter can measure right heart pressures, blood sampling, solution infusion, and cardiac output measurements by thermodilution when used with a compatible monitoring platform


Model numbers
Model Swan-Ganz Pacing Catheters Size (F) Length (cm) D200F7 Pacing-TD Catheter 7 110 -
TABLET CUTTER
Having a definite quality management system, we are immersed in bringing forth a top class consignment of Tablet Cutter. .
Product Details:
Pill Splitter with 1 Storage Compartment | Safe Design with Retracted Blade | Suitable for Multiple Size Tabs
-
TAZUNA BALLOONTazuna®- Semi-Compliant PTCA Balloon Catheter
Tazuna®- Semi-Compliant PTCA Balloon Catheter
Tazuna® rapid exchange PTCA balloon catheter is intended for use during percutaneous transluminal coronary angioplasty (PTCA) for the purpose of improving myocardial blood flow in a localized stenotic lesion of the coronary arteries.
Tazuna is a high performance balloon utilizing a combination of Terumo’s technologies to improve crossability and pushability to treat the most complex lesions.
Shaft diameter 1.9 Fr (0.63 mm) Proximal
2.4 Fr (0.80 mm) Distal for 1.25 mm to 2.00 mm
2.5 Fr (0.83 mm) Distal for 2.25 mm to 3.00 mmUsable length 145 cm Nominal pressure 6 atm (608 kPa) Rated burst pressure 14 atm (1419 kPa) Guidewire compatibility Maximum diameter 0.014″ (0.36 mm) Lesion entry profile 0.40 mm (1.25 mm to 2.25 mm / 10 mm)
0.42 mm (1.25 mm to 2.25 mm / 15 to 20 mm and 2.5 mm, 3.0 mm)Coating Hydrophilic Sizes Available Item Code 1.25/10 TCO01DC-RK1210EH 1.25/15 TCO01DC-RK1215EH 1.5/10 TCO01DC-RK1510EH 1.5/15 TCO01DC-RK1515EH 2.0/10 TCO01DC-RK2010EH 2.0/15 TCO01DC-RK2015EHW 2.0/20 TCO01DC-RK2020EHW 2.5/10 TCO01DC-RK2510EHW 2.5/15 TCO01DC-RK2515EHW 2.5/20 TCO01DC-RK2520EHW 3.0/10 TCO01DC-RK3010EHW 3.0/15 TCO01DC-RK3015EHW 3.0/20 TCO01DC-RK3020EHW -
TEDAGRAM 1626W/8526
3M Tegaderm HP Transparent I.V. Film Dressing (8526IN) is a frame style dressing consists of a thin film backing with a non-latex, hypoallergenic adhesive. 3M Tegaderm HP Transparent Film Dressing (8526IN) is breathable, allowing good oxygen and moisture vapor exchange. It is waterproof and impermeable to liquids, bacteria, and viruses. *An intact dressing protects the site from outside contamination.
-
TELEFLEX GLIDE LINER V3 CATHETER
TELEFLEX GLIDE LINER V3 CATHETER
Guide extension catheter with half-pipe technology
In 2009, the GuideLiner® Catheter revolutionized the concept of guide extension, creating new possibilities in interventional cardiology. Now in its third generation, the GuideLiner® V3 Catheter continues to build on a history of innovation and performance—one that’s been demonstrated with more than half a million catheters in cath labs around the world.1
Designed to perform
It’s not just the proprietary half-pipe technology that sets the GuideLiner® V3 Catheter apart. The coil-reinforced extension is specifically designed to enable dependable deep-seating for the delivery of interventional devices to distal locations.
Half-pipe technology
The half‑pipe channel is designed to minimize device/collar interaction by directing and aligning devices through the collar transition, facilitating smooth device entry and seamless delivery.
Tortuosity tested
From challenging lesions to impossibly acute angles, percutaneous coronary interventions have grown more complex. Since being introduced, GuideLiner® Catheters have been recognized by interventionalists as essential tools for addressing difficult anatomies.
Available in five sizes: 5, 5.5, 6, 7 and 8 Fr.
-
TEMPO CATHETER
The Cordis TEMPO AQUA Diagnostic Catheter is an angiographic catheter providing excellent flow rates, optimal contrast delivery, and vessel opacification.
Product Description
TEMPO Angiographic Catheter has a braided, nylon shaft and comes in a large variety of shapes to meet the most exacting needs.
- Braided nylon body
- Neon tip (tungsten filled radiopaque tip)
- High flow rates
- 1200 psi pressure limit
- SLX™ coating
Cordis has an extensive line of diagnostic catheters both for selective and flush applications. NYLEX™, TEMPO™ and TEMPO AQUA Catheters have a nylon body, while the SUPERTORQUE™ Catheters have a polyurethane shaft.
Flush catheters are available: braided and non-braided, straight and pigtail versions, extensive range of lengths and French-sizes.
All the Cordis selective catheters have a unique braiding that provides excellent torque control. TEMPO AQUA Catheter has a bonded hydrophilic coating enabling a smooth passage through the vessel. All commonly used shapes are available in different French-sizes.
TEMPO AQUA Catheters offer:
- Precise control and sturdy support. High-strength nylon construction and braided shaft design give strength and flexibility for superb torque response and maximum tactile control.
- Enhanced tip radiopacity. An extended, tungsten-filled Neon tip, with superb visualization for rapid and precise catheter placement. Less need for contrast injection.
- Flexible tip. Patented soft design and long non-braided distal end increases tip flexibility, helps reduce risk of vessel trauma and promotes patient comfort.
Smoother delivery. Hydrophilic SLX™ Coating minimizes friction between the catheter and the vessel wall for rapid and smooth vessel engagement.
Cordis has an extensive line of diagnostic catheters both for selective and flush applications. NYLEX™, TEMPO™ and TEMPO™ AQUA catheters have a nylon body and the SUPERTORQUE™ Catheter line has a polyurethane shaft.
Flush catheters are available: braided and non-braided, straight and pigtail versions, extensive range of lengths and French-sizes.
All the Cordis selective catheters have a unique braiding that provides excellent torque control. TEMPO™ AQUA Catheter has a truly bonded hydrophilic coating, that enables a smooth passage through the vessel. All commonly used shapes are available in different French-sizes.
-
-
-
TERUMO GLIDE CATHETER cobra2 (C2) 4FR ZB5410GA
TERUMO GLIDE CATHETER Sim2 5FR RF*WA25110M
TERUMO GLIDE CATHETER cobra2 (C2) 5FR RF*ZB5510GM
TERUMO GLIDE CATHETER Sim1 5FR RF*WA15110M
TERUMO GLIDE CATHETER H1 5FR RF*WB15110M
TERUMO GLIDE CATHETER H2 5FR RF*WB25110M
-
-
TERUMO OXYGENATOR RX25 3CX*RX25RW
TERUMO OXYGENATOR RX05 3CX*RX05RW
TERUMO OXYGENATOR RX15 3CX*RX15RW30
TERUMO OXYGENATOR fX15 3CX*FX15RE30C
TERUMO OXYGENATOR Fx25 3CX*FX25RWC
TERUMO CAPIOX FX Advance Arterial filter AL8X
-
TERUMO REJUIN PLUS PTCA DILATATION CATHETER
TERUMO REJUIN PLUS PTCA DILATATION
CATHETER
DESCRIPTION
TERUMO Ryujin Plus rapid exchange balloon catheter is intended for use during percutaneous transluminal coronary angioplasty (PTCA) for the purpose of improving myocardial blood flow in the localized stenotic lesion of the coronary arteries.
his device is designed for crossing routine lesions without compromising trackability
Characteristics
- Flexible distal shaft and hydrophilic coating for good trackability
- Low profile enables kissing balloon technique in 6-Fr large lumen (< 0.070″ / 1.80 mm) guiding catheter
- Fixed outer and inner tube prevents accordion folds from forming at the balloon section
- Broad selection of diameters (from 1.25 mm to 4.0 mm) and lengths (from 10 mm to 40 mm)
General specifications
Shaft diameter 2.0 Fr (0.67 mm) Proximal
2.4 Fr (0.80 mm) Distal for 1.25 mm to 2.0 mm
2.5 Fr (0.83 mm) Distal for 2.25 mm to 3.00 mm
2.6 Fr (0.87 mm) Distal for 3.50 mm and 4.00 mmUsable length 145 cm Nominal pressure 6 atm (608 kPa) Rated burst pressure 14 atm (1419 kPa) for 1.25 mm to 3.00 mm
12 atm (1216 kPa) for 3.50 mm and 4.00 mmGuidewire compatibility Maximum diameter 0.014″ (0.36 mm) Lesion entry profile 0.43 mm Coating Hydrophilic Item specifications
Balloon diameter (mm) Balloon length (mm) 10 15 20 30 40 1.25 DC-RH1210EH* DC-RH1215EH* — — — 1.50 — DC-RH1515EH* DC-RH1520EH* — — 2.00 — DC-RH2015EHW DC-RH2020EHW DC-RH2030EHW DC-RH2040EHW 2.25 DC-RH2210EHW DC-RH2215EHW DC-RH2220EHW DC-RH2230EHW DC-RH2240EHW Sizes Available Item Code RX 4.0/15 TCO01DC-RH4015EHW RX 4.0/20 TCO01DC-RH4020EHW OTW 1.25/10 LONG SHAFT TCO01DC-PH1210LH -
TERUMO TAZUNA BALLOON ETC SIZES
TERUMO REJUIN ETC SIZES
TERUMO ACCUFORCE ETC SIZES
TERUMO ELIMINATE ASSPIRATION CATH 6FGC EG1602
-
THERMAL PRINT MEDIA TYPE 1 (NORMAL) UPP-110S 110MM*20M
These Sony Thermal Paper Normal are widely used for Ultrasound printing.
Overview:
- A6 width B&W High Quality pint media (type I) for use in UP-X898MD / D898MD / D898DC / 897MD / D897 / 895 / D895 / 890 / D890 / 860 / D860 printers
- This product is available in multiples of 10. Mainly used in Ultrasound, Dental and Microscopy applications
Other Deatails:
- Type 1 Normal
- Thermal Print Media Consommable Pour Imprimante Thermique
-
Thermovent T2
It is designed specifically for neonatal patients · It is the original, disposable, in-line HME · It is designed in both angled and straight versions for use in … -
THORACIC LAPAROSCOPIC TROCAR
THORACIC LAPAROSCOPIC TROCAR
Description
This disposable Thoracic Trocar is used in thoracoscopic and other minimally invasive procedures to establish a port for access to internal organs where insufflation is not required. It is a sterile single-patient-use instrument for multiple choices.
- Elliptical blunt tip provides safety from injuring tissue and viscera.
- Special threaded design and suture anchoring device make cannula stable fixed
Product size range
Ref. No. Product information 1850-V6ST Thoracic Trocar 6mm/7cm 1850-V11ST Thoracic Trocar 11mm/7cm 1850-V13ST Thoracic Trocar 13mm/7cm 1850-V15T Thoracic Trocar 15mm/7cm Product Information
Working Length (mm) Shaft Diameter (mm) BVT Series trocars/Safe tip/5mm/100mm 100 5 BVT Series trocars/Safe tip/5mm/150mm 150 5 BVT Series trocars/Safe tip/5mm/100mm 100 10 BVT Series trocars/Safe tip/5mm/150mm 150 10 BVT Series trocars/Safe tip/5mm/100mm 100 11 BVT Series trocars/Safe tip/5mm/150mm 150 11 BVT Series trocars/Safe tip/5mm/100mm 100 12 BVT Series trocars/Safe tip/5mm/150mm 150 12 BVT Series trocars/Safe tip/5mm/100mm 100 15 BVT Series trocars/Safe tip/5mm/150mm 150 15 BVT Series trocars/Safe tip/5mm/100mm 100 5 BVT Series trocars/Safe tip/5mm/150mm 150 5 BVT Series trocars/Safe tip/5mm/100mm 100 10 BVT Series trocars/Safe tip/5mm/150mm 150 10 BVT Series trocars/Safe tip/5mm/100mm 100 11 BVT Series trocars/Safe tip/5mm/150mm 150 11 BVT Series trocars/Safe tip/5mm/100mm 100 12 BVT Series trocars/Safe tip/5mm/150mm 150 12 BVT Series trocars/Safe tip/5mm/100mm 100 15 BVT Series trocars/Safe tip/5mm/150mm 150 15 -
THREE CVC LUMEN
Central venous catheter –
A central venous catheter (CVC), also known as a central line, central venous line, or central venous access catheter, is a catheter placed into a large vein. It is a …
Central Venous Catheters (CVC): Purpose, Types, Procedure
Central Venous Catheters (CVC): Purpose, Types, ProcedureCentral venous catheter – Canadian Cancer SocietyA central venous catheter (CVC) is a thin, flexible tube (catheter) that is placed into the large vein above the heart, usually through a vein in the neck, chest or ..Central line (central venous catheter) -
TORNUS MICROCATHETER GUIDE WIRE
ASAHI TORNUS MICROCATHETER GUIDE WIRE
TORNUS
ltimate Performance for the Treatment of Highly Stenosed Lesions.Stainless Steel Coil Shaft
- For outstanding support, pushability, and torque performance
- Shaft structure enables rotation of the catheter, providing excellent crossability
Distal Radiopaque Marker
- For easy visualization of the distal tip
Benefits
- Guide wire support
- Lesion crossing
- Guide wire exchange
A support catheter that enables guide wire crossing of highly stenosed lesion. Tornus can follow the wire across the highly stenosed lesion to allow guide wire exchange.

■Rotation limit
When the tip of Tornus does not advance, limit the rotation of Tornus at 20 times. Once it reaches 20 times, rewind the catheter and release the torque accumulation. Then, start rotating it again to advance.Product Spec
Tip Outer Diameter 0.61mm (1.8Fr) / 0.70mm (2.1Fr) Hydrophilic Coating Length 135cm Structure 

Category - Microcatheter
- Complex
Order Information
Product Name Catalog No. Usable Length Tip(O.D) Distal Shaft(O.D) Proximal Shaft(O.D) Tip(I.D) Shaft(I.D) Tornus 2.1Fr AT24135 135cm 0.61mm (1.8Fr) 0.71mm (2.1Fr) 1.1mm (3.3Fr) 0.41mm (0.016″) 0.46mm (0.018″) Tornus 2.6Fr AT35135 135cm 0.70mm (2.1Fr) 0.88mm (2.6Fr) 1.00mm (3.0Fr) 0.41mm (0.016″) 0.64mm (0.025″) -
TR BAND (REDICAL BAND)
Product Overview
TR Band is a compression device designed to assist haemostasis of the radial artery after a trans-radial procedure.
Radial hemostasis device used for Cardiac Cath or Interventional Radiology procedures.
Heparin 50 units/kg or less—band remains in place 60 minutes. Heparin (or comparable agent) greater than 50 units/kg —band remains in place for 120 minutes
The TR Band inflator syringe is filled with 18 cc of air and slowly injected into the one-way side port which inflates the balloon overlying the radial artery.
Apply the TR Band® Compression Device by aligning green marker, which is located on the center of the larger compression balloon (large) 1-2mm proximal to the puncture site, and fix the strap on the wrist with the adjustable fastener.
- TR Band is a compression device designed to assist haemostasis of the radial artery after a trans-radial procedure.
- Through the transparent structure designed for visual control and selective compression of the radial artery to allow blood return and preserve patency, TR Band assists in maintaining radial artery patency at the time of haemostasis in order to prevent future radial artery occlusion1,2
*1: Rathore S. et al., 2010. A Randomized Comparison of TR Band and Radistop Hemostatic Compression Devices After Trans-radial Coronary Intervention. Catheterization and Cardiovascular Interventions, 76(5), pp.660–667.*2: Pancholy et al., 2009. Impact of Two Different Hemostatic Devices on Radial Artery Outcomes after Trans-radial Catheterization. J. Invasive Cardiology, 21:101-104.
Features and Benefits

-
TransparencyEnsure continuous observation of access site.
-
Green markerEasy to apply the device to appropriate position.
-
Dual compression balloonsProvide precise compression to radial artery and avoid nerve compression. It can reduce pain for patient.
-
Syringe systemPermit accurate pressure adjustment.
-
Belt with magic tapeMake application fast and simple.
-
Support plateFits the wrist shape and fix the device construction.

Item Specifications
Shelf life: 30 monthssize Item Code Length Regular size XX*RF06 24cm Large size XX*RF06L 29cm 

-
Tracheostomy Tube Tracoe Twist Double Lumen
Tracoe Twist Double Lumen Fenestrated Tracheostomy Tube Uncuffed
The TRACOE twist and TRACOE twist plus tracheostomy tubes are used as ventilation and therapy tubes with inner cannulas in hospitals, rehabilitation, and community settings. A special feature of TRACOE twist tubes is the anatomically shaped neck flange that moves in both the vertical and horizontal axes. Patients can turn their heads freely, without the tracheostomy tube exerting any strong pressure on the trachea. It is easy to attach or exchange the neck strap while the tube is in situ.
Sizing of the two product lines always corresponds to the inside diameter of the inner cannula. For example, when it says 8 mm on the neck flange, the lumen of the inner cannula is 8 mm.For breathing and ventilation, the lumen should be as large as possible – that is why the internal measurement is given. For the patient, every millimetre counts. If the diameter of the lumen is reduced from 8 to 7 mm, the air supply is 41 % less and there is a huge increase in the effort required to breathe. Changing from 8 to 9 mm increases the air supply by 60 %, while the effort required to breathe remains the same.
-
TRANSREDIAL SHEATH
Elastomeric properties allow RAIN Sheath Introducer to flex and bend in the radial anatomy. RAIN Sheath Introducer’s polymeric material reduces the impact of kinking – avoiding the sharp edges that can injure the vessel wall and contribute to complications.
LOW
PROFILE DESIGN
Available in:
7F in 6, 6F in 5, 5F in 4, 4F
in 3
Enables maximum operating
space while minimizing
puncture sizePROPRIETARY
KINK RECOVERY
TECHNOLOGY™
Elastomeric properties
allow the RAIN Sheath™
Introducer to bend and flex
to maintain lumen integrity
LUBRICIOUS HYDROPHILICCOATING
Facilitates smoother, easier
insertion and removalHEXACUSPID
HEAMOSTASIS VALVE
Designed to preserve
hemostasis and reduce risk
of bleedbackLOW PROFILE WITH OPTIMAL GUIDE
CATHETER SUPPORT
Available in 4F, 5F, 6F, 7F and 10 cm and 16 cm lengths
• Provides structure and stability without adding thickness
• Optimizes operating space while minimizing the access size
• Minimizes radial puncture size, a key factor in reducing vessel spasm
and radial artery occlusion1.OPTIMISED TRANSITIONS
• Designed for atraumatic insertion
• Smooth transitions and tapered tip
to reduce insertion force.STAINLESS STEEL WIRE
• Flex Straight tip
• 0.021″ diameter x 45cm length
• For use with 21G metallic needlesNITINOL WIRE
• Floppy tip
• 0.021″ diameter x 45cm length
• Bare wire: For use with 21G metallic needles
• Hydrophilic wire: For use with 20G IV cathetersPOLYMER WIRE
• Short angle tip
• 0.021″ diameter x 45cm length
• For use with 20G and 22G IV Catheter needles -
Two Way Foley Hemodialysis Catheter
Arrow Edge Antegrade-Tunneled Chronic Hemodialysis Catheter
Staggered V-Tip Design for Optimal Performance
The Arrow Edge Catheter is designed to provide optimal performance by delivering high flow rates, up to 400 cc per minute, at low pressures.1 The crescent-shape of the catheter ‘s distal V- tip is designed to promote blood flow even if the tip is resting against the vessel wall.
- Innovative V-tip design and catheter tip orientation minimize the risk of recirculation when placed in the right atrium2
- Compatible with broad spectrum of antiseptic agents, including alcohol and iodine3
- Kits feature Arrow SmartSeal Hemostatic Peelable Dialysis Sheath

References:
- In vitro test performed by an independent laboratory (Citech, Plymouth Meeting, PA). Laboratory test results may not be indicative of clinical performance.
- Caridi J, Ross E, Aspilcueta A, Wiley S. The cannon-catheter-a prospective analysis. J of Vasc and Interv Radiol. 2010;21:1588-1590. The Arrow Edge Catheter is the antegrade version of and has the same tip design as the retrograde Arrow Cannon Catheter. Both catheters are designed for placement in the mid-right atrium.
- Alcohol, alcohol-based solutions (e.g., Hibiclens, ChloraPrep), iodine-based solutions (Povidone-Iodine), PEG-based ointments (e.g., Bactroban), hydrogen peroxide or ExSept Plus are accepted for use with this catheter.
The Arrow Edge catheter is indicated for use in attaining long-term vascular access for hemodialysis and apheresis. The Arrow Edge catheter is inserted percutaneously and is preferentially placed into the internal jugular (IJ) vein. Alternately, this catheter may be inserted into the subclavian vein although the jugular vein is the preferred site. Catheters greater than 40 cm are intended for femoral vein insertion. Arrow Edge catheter is intended for use in adult patients.
Refer to the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions. Information in this material is not a substitute for the product Instructions for Use.
-
ULTIMATE BROS 3
ULTIMATE BROS 3
ULTIMATEbros 3
Good choice for mixed morphology lesions due to guide wires long hydrophilic coating which maintains high maneuverability, allowing for improved wire manipulation in highly stenosed lesions. Fine shaping improves vessel selectivity and reduces the risk of false lumen expansion. Chronic Total Occlusion indicated.

TIP LOAD 
TIP RADIOPACITY 11 cm COATING HYDROPHILIC* WITH UNCOATED DISTAL TIP
Hydrophilic 40 cm – uncoated distal tipTIP SHAPE 
Ordering Information
PRODUCT CATALOG NO. TIP SHAPE LENGTH (CM) DIAMETER (INCH(MM)) RADIOPAQUE SEGMENT (CM) SPRING COIL LENGTH (CM) COATING ULTIMATEbros 3 AHW14S003S Straight 180 0.014 (0.36) 11 11 HYDROPHILIC* WITH UNCOATED DISTAL TIP
Hydrophilic 40 cm – uncoated distal tipULTIMATEbros 3 300 cm AHW14S303S Straight 300 0.014 (0.36) 11 11 HYDROPHILIC* WITH UNCOATED DISTAL TIP
Hydrophilic 40 cm – uncoated distal tipIndications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
-
ULTRASOUND GEL
Ultrasound gel is the best medium to achieve these functions. It transfers ultrasound waves between the patient’s skin and the transducer and reduces the mismatch of acoustic impedance as it has matching acoustic impedance with soft tissues (1.5 MRayls) for complete transmission of ultrasound waves.
-
UNIVERSAL II ST
UNIVERSAL II
The HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II Guide Wire features the same trusted design as the HT BMW UNIVERSAL, with advanced coatings for smooth device movement and coating durability.
HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ Guide Wire
PRODUCT PART NUMBER TIP RADIOPACITY TIP SHAPE DISTAL COATINGS WIRE LENGTH MARKER HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009664 3 cm Straight Hydrophilic 190 cm Marker HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009664J 3 cm J Hydrophilic 190 cm Marker HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009665 3 cm Straight Hydrophilic 300 cm Marker HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009665J 3 cm J Hydrophilic 300 cm Marker HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009666 3 cm Straight Hydrophilic 190 cm No Marker HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009666J 3 cm J Hydrophilic 190 cm No Marker HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009667 3 cm Straight Hydrophilic 300 cm No Marker HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II™ 1009667J 3 cm J Hydrophilic 300 cm No Marker -
UROBAG
– The urine collection bag comes with a 2 litre capacity bag which is provided with 100 cm long super smooth kink resistant tubing
– The urine bag features a specially designed moulded handle to facilitate easy carrying and handling of bag and holds the tube in upright position to prevent kinking
– These urine collection bags are equipped with an efficient non-return valve with top outlet
– Its modified tapered connector facilitates aseptic catheter-urine bag connection
– These urine bags are sterile and individually packed in ribbon pack
– The urine bag come in a standard packing of 25 bags per box
– As the name suggest, urine collection bags are used to collect and temporarily store urine. It is attached to a catheter (tube) that is connected to the patient”s bladder through the urethra and the urine is passed through this tube into the urine bag. Such devices are used by people that may be suffering from urinary incontinence/ leakage, difficulty in urination, urinary tract infections, during and after certain types of urological and gynaecological surgeries, and other ailments.
– Most urine bags are not recommended to be re-used for more than a month even with thorough cleaning every time the bag is drained. If the bag looks dirty or smells bad, then it should not be used and disposed off immediatel
-
Versaturn guide wire
Hi-Torque Versacore™ family of peripheral workhorse guide wires are designed to meet an array of clinical needs, from start to finish.
These size are also available-
XIENCE ALPINE 2.5*15 XIENCE ALPINE 2.5*23 XIENCE ALPINE 2.5*33 XIENCE ALPINE 2.75*23 XIENCE ALPINE 3.0*15 XIENCE ALPINE 3.0*23 XIENCE ALPINE 3.0*28 XIENCE ALPINE 3.0*33 XIENCE ALPINE 3.0*48 XIENCE ALPINE 3.5*33 XINECE ALPINE 2.0*08 -
-
VYPRO 11 MESH
15cm X 15cm Vypro Mesh brought forth by us is designed to be utilized for the stabilization of fascial structures of the abdominal wall as well as tissue reinforcement. The following mesh is well manufactured by ingenious professionals utilizing the highest grade absorbent, & lightweight multi-filament mesh and prolene structure with advanced processing method in absolute compliance with medical industry standards and norms. Safe & convenient to use, and flexible, 6cm X 11cm Vypro Mesh is provided in protective box pack of one piece.
-
Weck Hem-o-lok
Weck Hem-o-lok Polymer Ligation System – Clips
Description:
Weck Hem-o-lok Non-absorbable Polymer Locking Clips provide cool secure ligation; clip locks onto the vessel. The Weck Hem-o-lok system is available in a range of clip sizes Medium, Medium-Large, Large and Extra-Large. The Non-Absorbable polymer clip is inert, nonconductive, radiolucent, and does not interfere with CT or X-ray diagnostics.
Catalog # Clip Size Clips/Cartridge Cartridges/Box Clips/Box 544220 Medium 6 14 84 544230 Medium-Large 6 14 84 544240 Large 6 14 84 544250 Extra-Large 6 14 84 -
WHISPER ES PTCA GUIDEWIRE
Product Details:
Model Name/Number 1011834H Material PTCA Guide Wire Hi Torque Whisper Extra Support Guide Wire Packaging Type Packet Brand Abbott Type Angiography Length 190cm Diameter .014 inch Explore Abbott’s growing portfolio of Workhorse and Specialty guide wires. … a soft tip, and provide enough support to deliver most interventional devices. … HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL … HI-TORQUE WHISPER MS ….. Use of this technique carries additional patient risks, including the risk that the …
Additional Information:
- Production Capacity: long term
- Delivery Time: 3-4 working days
- Packaging Details: 5pcs in (1-box)













































