Archives: Shop
Showing 241–280 of 332 results
-
PROGREAT® MICROCATHETHER
PRODUCT OVERVIEW
PROGREAT® Microcatheters are designed to allow navigation through tortuous peripheral vessels for optimal access and delivery of therapeutic embolization.
Terumo Progreat 2.7Fr. Microcatheter is Designed to provide optimal trackability and support even in the most tortuous anatomy.
DESIGNED TO CONFIDENTLY DELIVER EMBOLOTHERAPY
- Tungsten coil reinforcement for kink resistance2
- PTFE inner layer is designed for exceptional guidewire tracking, with virtually frictionless delivery of coils and other embolics2
- DMSO Compatible3
- Radiopaque 0.7 mm platinum/iridium markers allow for rapid and precise positioning4

DESIGNED TO ENHANCE ACCESS TO SMALL PERIPHERAL VESSELS
- TERUMO Glide TechnologyTM hydrophilic coating enhances navigation through tortuous anatomy1,2
- Unique varied tungsten coil pitch construction provides distal flexibility and proximal pushability, enhancing vessel selectivity and catheter placement.

PROGREAT® COAXIAL MICROCATHETER SYSTEM
- Preloaded with uniquely designed 0.021” GLIDEWIRE® GT for the 2.8Fr system and 0.018″ GLIDEWIRE® GT for the 2.4Fr system1
- Available in 2.8Fr and 2.4Fr
- Enables simultaneous preparation of microcatheter and guidewire, which may save time and increase procedural efficiency1
PROGREAT 2.4 COAXIAL PROVEN TO REACH DISTAL VESSELS WITH EASE⁴
- Provides greater vessel selectivity and demonstrated superiority in traversing tortuous anatomy
- Provides best-in-class kink resistance, demonstrated in both the distal and proximal shaft.

PROGREAT® Microcatheter Product Codes
Includes hemostatic valve and shaping mandrel
Fr Size Product Code Length (cm) Tip Shape Max Pressure (psi) RO Markers Hydrophilic Coating Length (cm) 2.4 MC*PB2411Y 110 Straight 750 1 50 MC*PB2413Y 130 Straight 1 70 MC*PB2413ZRA 130 70 Deg. Angle 1 70 MC*PB2413ZRC 130 J Curve 1 70 MC*PV2415Y 150 Straight 2 90 MC*PV2415ZRA 150 70 Deg. Angle 2 90 MC*PV2415ZRC 150 J Curve 2 90 2.7 MC*PC2711Y 110 Straight 750 – 50 MC*PC27137 130 Straight – 70 2.8 MC*PB2811Y 110 Straight 900 1 50 MC*PB2813Y 130 Straight 1 70 MC*PV2815Y 150 Straight 2 90 PROGREAT® Coaxial Microcatheter System Codes
Includes unique GLIDEWIRE® GT Guidewire, wire stopper, guidewire introducer, hemostatic valve, 2.5 mL syringe, and shaping mandrel
Fr Size Product
CodeLength
(cm)Max Pressure
(PSI)RO Markers Hydrophilic
Coating Length
(cm)Glidewire® GT
Length
(cm)Glidewire® GT Size
(in)2.4 Fr MC*PE24111YB 110 750 1 50 120 0.018 2.4 Fr MC*PE24131YB 130 750 1 70 140 0.018 2.4 Fr MC*PE24151YV 150 750 2 90 160 0.018 2.7 Fr MC*PE27111Y 110 750 – 50 120 0.021 2.7 Fr MC*PE27131Y 130 750 – 70 140 0.021 2.8 Fr MC*PE28111YB 110 900 1 50 120 0.021 2.8 Fr MC*PE28131YB 130 900 1 70 140 0.021 2.8 Fr MC*PE28151YV 150 900 2 90 160 0.021 PRODUCT SPECIFICATIONS
Catheter OD Length
(cm)Inner Diameter
(in/mm)Max GW
(in)Embolic
CompatibilityDead Space Volume
(mL)Actual Flow Rate* (mL/sec) @ 750 psi Actual Flow Rate* (mL/sec) @ 900 psi 2.4/2.9Fr
(0.80/0.97mm)110 0.022″/0.57 0.018″ 0.018″ Coils/HydroPearl®
600 ± 75 μm0.48 2.3 – 2.4/2.9Fr
(0.80/0.97mm)130 0.022″/0.57 0.018″ 0.018″ Coils/HydroPearl®
600 ± 75 μm0.53 2 – 2.4/2.9Fr
(0.80/0.97mm)150 0.022″/0.57 0.018″ 0.018″ Coils/HydroPearl®
600 ± 75 μm0.58 1.8 – 2.7/2.9Fr
(0.90/0.97mm)110 0.025″/0.065 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.57 3.5 – 2.7/2.9Fr
(0.90/0.97mm)130 0.025″/0.065 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.64 3.2 – 2.8/3.0Fr
(0.93/1.00mm)110 0.027″/0.70 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.61 4.1 4.7 2.8/3.0Fr
(0.93/1.00mm)130 0.027″/0.70 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.68 3.7 4.3 2.8/3.0Fr
(0.93/1.00mm)150 0.027″/0.70 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.75 3.1 3.9 REFERENCES
RX ONLY. Refer to the product labels and package insert for complete warnings, precautions, potential complications, and instructions for use.
- Catheter [Instructions for Use]. Somerset, NJ: Terumo Medical Corporation; 2016
- PROGREAT Catheter 510(k); 2003
- PROGREAT DMSO Compatibility Statement Letter
- Data on file.
-
Prymax Cathe Central Venous Catheter Ref-BCVC-5.503-08
Leveraging on our vast knowledge of this realm, we are betrothed in presenting an optimal quality seriesof Primax Central Venous Catheter. -
PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
Shaft diameter 1.9 Fr / 0.64 mm Proximal
2.5 Fr / 0.84 mm Mid
2.6 Fr / 0.86 mm DistalUsable length 145 cm Balloon markers 2 Nominal pressure 12 atm / 1216 kPa Rated burst pressure 22 atm / 2229 kPa (2.0 mm to 4.0 mm)
20 atm / 2026 kPa (4.5 and 5.0 mm)Guidewire compatibility Maximum diameter 0.014″ / 0.36 mm Lesion entry profile 0.43 mm Coating Hydrophilic Item specifications
Ordering Information
Balloon
diameter
(mm) Balloon length (mm) / Item references 6 8 12 15 20 25 30 2.00 DC-RM2006HSW DC-RM2008HSW DC-RM2012HHW DC-RM2015HHW DC-RM2020HHW — — 2.25 DC-RM2206HSW DC-RM2208HSW DC-RM2212HHW DC-RM2215HHW DC-RM2220HHW — — 2.50 DC-RM2506HSW DC-RM2508HSW DC-RM2512HHW DC-RM2515HHW DC-RM2520HHW DC-RM2525HHW DC-RM2530HHW 2.75 DC-RM2706HSW DC-RM2708HSW DC-RM2712HHW DC-RM2715HHW DC-RM2720HHW — — 3.00 DC-RM3006HSW DC-RM3008HSW DC-RM3012HHW DC-RM3015HHW DC-RM3020HHW DC-RM3025HHW DC-RM3030HHW 3.25 DC-RM3206HSW DC-RM3208HSW DC-RM3212HHW DC-RM3215HHW DC-RM3220HHW — — 3.50 DC-RM3506HSW DC-RM3508HSW DC-RM3512HHW DC-RM3515HHW DC-RM3520HHW DC-RM3525HHW DC-RM3530HHW 3.75 DC-RM3706HSW DC-RM3708HSW DC-RM3712HHW DC-RM3715HHW DC-RM3720HHW — — 4.00 DC-RM4006HSW DC-RM4008HSW DC-RM4012HHW DC-RM4015HHW DC-RM4020HHW — — 4.50 DC-RM4506HSW DC-RM4508HSW DC-RM4512HSW DC-RM4515HSW — — — 5.00 DC-RM5006HSW DC-RM5008HSW DC-RM5012HSW DC-RM5015HSW — — — Please quote above item reference codes when placing an order.
Balloon Compliance
Balloon
diameter
(mm) Pressure (atm) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2.00 1.58 1.65 1.72 1.79 1.84 1.88 1.92 1.95 1.98 2.00* 2.01 2.03 2.04 2.05 2.06 2.08 2.09 2.10 2.12 2.13** 2.14 2.15 2.17 2.25 1.96 2.01 2.06 2.11 2.14 2.16 2.19 2.21 2.23 2.25* 2.26 2.28 2.29 2.31 2.32 2.34 2.35 2.36 2.38 2.39** 2.41 2.42 2.44 2.50 2.19 2.24 2.30 2.36 2.38 2.41 2.44 2.46 2.48 2.50* 2.52 2.53 2.55 2.56 2.58 2.60 2.61 2.63 2.64 2.66** 2.68 2.69 2.71 2.75 2.43 2.48 2.53 2.59 2.62 2.65 2.67 2.70 2.73 2.75* 2.77 2.79 2.80 2.82 2.84 2.86 2.87 2.89 2.91 2.93** 2.94 2.96 2.98 3.00 2.65 2.71 2.76 2.82 2.85 2.89 2.92 2.95 2.97 3.00* 3.02 3.04 3.06 3.08 3.10 3.11 3.13 3.15 3.17 3.19** 3.21 3.23 3.25 3.25 2.89 2.95 3.01 3.07 3.10 3.14 3.17 3.20 3.22 3.25* 3.27 3.29 3.31 3.33 3.35 3.37 3.39 3.42 3.44 3.46** 3.47 3.48 3.51 3.50 3.13 3.19 3.26 3.32 3.35 3.39 3.42 3.45 3.47 3.50* 3.52 3.54 3.57 3.59 3.61 3.63 3.65 3.68 3.70 3.72** 3.74 3.74 3.76 3.75 3.37 3.44 3.50 3.56 3.60 3.63 3.66 3.69 3.72 3.75* 3.77 3.80 3.82 3.84 3.86 3.88 3.90 3.92 3.94 3.96** 3.98 3.99 4.01 4.00 3.58 3.65 3.72 3.79 3.83 3.87 3.90 3.94 3.97 4.00* 4.03 4.05 4.07 4.09 4.11 4.13 4.15 4.17 4.19 4.21** 4.23 4.26 4.28 4.50 4.02 4.10 4.19 4.28 4.32 4.37 4.40 4.44 4.47 4.50* 4.53 4.56 4.59 4.63 4.66 4.68 4.71 4.75** 4.78 4.81 4.84 4.87 4.91 5.00 4.52 4.59 4.67 4.75 4.80 4.85 4.89 4.93 4.96 5.00* 5.03 5.07 5.10 5.13 5.16 5.19 5.22 5.26** 5.29 5.32 5.35 5.38 5.41 * Nominal pressure
** Rated burst pressureReferences
1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Ordering Information. Balloon diameter (mm) , Balloon length (mm) / Item references .Balloon markers: 2Usable length: 145 cmCoating: HydrophilicLesion entry profile: 0.43 mmStraight-Single Latex Plastic Terumo Accuforce Balloon Catheter, Size: Medium ; Application, Hospital ; Brand, Terumo ; Material, Latex ; Inner Diameter, 36mm. -
PTCA BALLOON MINI TREK
MINI TREK™ Coronary Dilatation Catheter’s ultra low profile design enables lesion access.
- Small chassis designed distinctively for MINI TREK™ Coronary Dilatation Catheter
- Available in sizes as small as 1.20 mm
TECHNICAL INFORMATION
TREK™ & MINI TREK™ CORONARY DILATATION CATHETERS NOMINAL PRESSURE (NP) 8 atm RATED BURST PRESSURE (RBP) 14 atm TIP ENTRY PROFILE 0.017 in (3.00 mm Ø) TIP CROSSING PROFILE 0.021 in average (3.00 mm Ø)
0.023 in maximumFOLDED BALLOON CROSSING PROFILE 0.032 in average (3.00 mm Ø)
0.036 in maximum (3.00 mm Ø)REFOLDED BALLOON CROSSING PROFILE 0.056 in maximum (3.00 mm Ø) RX NOTCH DIAMETER (FOR RX PLATFORM) 2.5 French average (3.00 mm Ø)
2.7 French maximum (all Ø)TIP LENGTH <3 mm BALLOON MATERIAL Pebax†, semi-compliant MARKER MATERIAL Flexible Tungsten/Pebax‡ CATHETER LENGTH 145 cm BALLOON COATING Hydrophilic MINIMUM GUIDE CATHETER 5 French (1.20 mm – 4.00 mm Ø)
6 French (4.50 mm & 5.00 mm Ø)MAXIMUM GUIDE WIRE COMPATIBILITY 0.014 in LATEX FREE Yes ORDERING INFORMATION
Broad Size Matrix with 77 RX Sizes and 75 OTW Sizes
BALLOON DIAMETER
(MM)BALLOON LENGTH (MM) 6 8 12 15 20 25 30 MINI TREK™
RX
(CTO INDICATED)1.20 1012268-06U 1012268-08U 1012268-12U 1012268-15U 1012268-20U – – 1.50 1012269-06 1012269-08 1012269-12 1012269-15 1012269-20 – – 2.00 1012270-06 1012270-08 1012270-12 1012270-15 1012270-20 1012270-25 1012270-30 TREK RX™ 2.25 1012271-06 1012271-08 1012271-12 1012271-15 1012271-20 1012271-25 1012271-30 2.50 1012272-06 1012272-08 1012272-12 1012272-15 1012272-20 1012272-25 1012272-30 2.75 1012273-06 1012273-08 1012273-12 1012273-15 1012273-20 1012273-25 1012273-30 3.00 1012274-06 1012274-08 1012274-12 1012274-15 1012274-20 1012274-25 1012274-30 3.25 1012275-06 1012275-08 1012275-12 1012275-15 1012275-20 1012275-25 1012275-30 3.50 1012276-06 1012276-08 1012276-12 1012276-15 1012276-20 1012276-25 1012276-30 3.75 1012277-06 1012277-08 1012277-12 1012277-15 1012277-20 1012277-25 1012277-30 4.00 1012278-06 1012278-08 1012278-12 1012278-15 1012278-20 1012278-25 1012278-30 4.50 – – 1012279-12 1012279-15 – – – 5.00 – – 1012280-12 1012280-15 – – – BALLOON DIAMETER
(MM)BALLOON LENGTH (MM) 6 8 12 15 20 25 30 MINI TREK™ II OTW
(CTO INDICATED)1.20 1012401-06Z 1012401-08Z 1012401-12Z 1012401-15Z 1012401-20Z – – 1.50 1012402-06A 1012402-08A 1012402-12A 1012402-15A 1012402-20A – – 2.00 1012403-06A 1012403-08A 1012403-12A 1012403-15A 1012403-20A – – TREK OTW™ 2.25 1012404-06 1012404-08 1012404-12 1012404-15 1012404-20 1012404-25 1012402-30 2.50 1012405-06 1012405-08 1012405-12 1012405-15 1012405-20 1012405-25 1012405-30 2.75 1012406-06 1012406-08 1012406-12 1012406-15 1012406-20 1012406-25 1012406-30 3.00 1012407-06 1012407-08 1012407-12 1012407-15 1012407-20 1012407-25 1012407-30 3.25 1012408-06 1012408-08 1012408-12 1012408-15 1012408-20 1012408-25 1012408-30 3.50 1012409-06 1012409-08 1012409-12 1012409-15 1012409-20 1012409-25 1012409-30 3.75 1012410-06 1012410-08 1012410-12 1012410-15 1012410-20 1012410-25 1012410-30 4.00 1012411-06 1012411-08 1012411-12 1012411-15 1012411-20 1012411-25 1012411-30 4.50 – – 1012412-12 1012412-15 – – – 5.00 – – 1012413-12 1012413-15 – – – -
PTCA BALLOON NC TREK
DES with most extensive clinical evidence with 50,000 patients enrolled worldwide. Facilitates early healing by abluminal gradient coating and reduced drug dose. Bifurcation Excellence. Flexible stent design. Advanced shaft technology. Reliable delivery in TRI.
The safety and effectiveness of this PTCA balloon catheter for the treatment of in-stent restenosis (ISR) has not been established. Potential Adverse Events.
The RX NC Takeru PTCA Balloon Dilatation Catheter is indicated for balloon dilatation of the stenotic portion in the coronary artery or bypass graft stenosis.
47732 – Basic Coronary Angioplasty Balloon Catheter … MINI TREK RX Coronary Dilatation Catheters. Catalog Numbers. Balloon Length. 6mm 8mm 12mm 15mm.
TECHNICAL INFORMATION
NC TREK™ CORONARY DILATATION CATHETER NOMINAL PRESSURE (NP) 12 atm RATED BURST PRESSURE (RBP) 18 atm TIP ENTRY PROFILE 0.020 in average (3.00 mm Ø)
0.022 in maximum (1.50 mm – 3.25 mm Ø)
0.024 in maximum (3.50 mm – 5.00 mm Ø)CROSSING PROFILE 0.027 in average (3.00 mm Ø)
0.032 in maximum (1.50 – 3.50 mm Ø)
0.037 in maximum (3.75 – 5.00 mm Ø)RX NOTCH DIAMETER 2.6 French average (3.00 mm Ø)
2.9 French maximumTIP LENGTH 3.5 +/- 0.5 mm (2.00 – 3.25 mm Ø)
4.5 +/- 0.5 mm (3.50 – 4.50 mm Ø)BALLOON MATERIAL Pebax‡, non-compliant MARKER MATERIAL Flexible Tungsten/Pebax‡ SHAFT LENGTH 143 cm COATING Hydrophilic MAXIMUM GUIDE WIRE COMPATIBILITY 0.014 in LATEX FREE Yes 
ORDERING INFORMATION
Broad Size Matrix with 59 Sizes Available
BALLOON DIAMETER
(MM)BALLOON LENGTH (MM) 6 8 12 15 20 25 NC TREK™
RX1.50 1012444-06 1012444-08 1012444-12 1012444-15 1012444-20 – 2.00 1012445-06 1012445-08 1012445-12 1012445-15 1012445-20 – 2.25 1012446-06 1012446-08 1012446-12 1012446-15 1012446-20 – 2.50 1012447-06 1012447-08 1012447-12 1012447-15 1012447-20 1012447-25 2.75 1012448-06 1012448-08 1012448-12 1012448-15 1012448-20 – 3.00 1012449-06 1012449-08 1012449-12 1012449-15 1012449-20 1012449-25 3.25 1012450-06 1012450-08 1012450-12 1012450-15 1012450-20 – 3.50 1012451-06 1012451-08 1012451-12 1012451-15 1012451-20 1012451-25 3.75 – 1012452-08 1012452-12 1012452-15 1012452-20 – 4.00 – 1012453-08 1012453-12 1012453-15 1012453-20 – 4.50 – 1012454-08 1012454-12 1012454-15 1012454-20 – 5.00 – 1012455-08 1012455-12 1012455-15 1012455-20 – COMPLIANCE CHART
INFLATION PRESSURE
(ATM)BALLOON DIAMETER (MM) 1.50 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.50 5.00 2 1.36 1.75 1.97 2.11 2.34 2.52 2.74 2.99 3.21 3.35 3.76 4.25 3 1.37 1.78 1.99 2.19 2.38 2.58 2.84 3.05 3.29 3.45 3.87 4.35 4 1.38 1.81 2.02 2.22 2.43 2.63 2.89 3.11 3.35 3.52 3.93 4.43 5 1.39 1.84 2.04 2.26 2.47 2.68 2.95 3.18 3.41 3.59 3.99 4.50 6 1.41 1.87 2.09 2.30 2.51 2.73 3.01 3.23 3.47 3.65 4.06 4.58 7 1.42 1.90 2.13 2.34 2.55 2.78 3.06 3.29 3.53 3.71 4.13 4.66 8 1.43 1.93 2.16 2.38 2.58 2.83 3.10 3.34 3.59 3.77 4.20 4.73 9 1.45 1.95 2.19 2.42 2.63 2.87 3.15 3.37 3.63 3.83 4.26 4.80 10 1.46 1.98 2.22 2.45 2.66 2.91 3.16 3.42 3.67 3.87 4.32 4.86 11 1.47 2.00 2.24 2.48 2.69 2.94 3.23 3.46 3.71 3.91 4.37 4.91 12 NP 1.49 2.01 2.26 2.50 2.71 2.97 3.26 3.49 3.74 3.95 4.41 4.96 13 1.50 2.03 2.28 2.53 2.73 3.00 3.28 3.51 3.77 3.98 4.45 5.00 14 1.51 2.04 2.30 2.55 2.76 3.02 3.31 3.54 3.80 4.01 4.49 5.04 15 1.52 2.06 2.32 2.57 2.78 3.04 3.34 3.57 3.82 4.04 4.53 5.08 16 1.53 2.07 2.33 2.59 2.79 3.07 3.36 3.60 3.85 4.07 4.57 5.12 17 1.53 2.09 2.35 2.62 2.82 3.09 3.39 3.62 3.88 4.10 4.60 5.16 18 RBP 1.54 2.10 2.37 2.64 2.84 3.11 3.41 3.65 3.91 4.13 4.64 5.20 19 1.55 2.12 2.39 2.67 2.86 3.14 3.44 3.68 3.93 4.16 4.68 5.24 20 1.56 2.13 2.41 2.69 2.88 3.16 3.47 3.71 3.96 4.19 4.72 5.28 21 1.57 2.15 2.42 2.72 2.90 3.18 3.50 3.75 – 4.22 4.76 5.33 22 1.58 2.17 2.45 2.75 2.93 3.21 – 3.78 – 4.25 – 5.37 -
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryurei™ has superior crossability1 thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1 results in enhanced trackability1 while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part, tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distal low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
Shaft diameter 1.9 Fr/0.64 mm Proximal • 2.5 Fr/0.84 mm Middle • 2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) • 2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) Usable length 145 cm Balloon markers # 1(Ø1.0 to Ø 1.5 mm) • 2(Ø2.0 to Ø4.0 mm) Nominal pressure 6 atm / 608 kPa Rated burst pressure Ø1.0 – 3.0 mm=14 atm(1419kPa) • Ø3.25 – 4.0 mm = 12 atm(1216 kPa) Guidewire compatibility Maximum diameter: 0.014″ / 0.36 mm Lesion entry profile 0.41 mm (Ø1.00 to Ø1.50 mm) • 0.43 mm (Ø2.00 to Ø4.00 mm) Coating Hydrophilic Item specifications
Balloon length / Product code
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH 1.25 mm DC-RR1205HH DC-RR1210HH DC-RR1215HH DC-RR1220HH 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1 Ryurei φ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ø 1.00 mm – Ø 1.50 mm.
** For Ryurei Ø 1.00mm – 5mm 2 Compared to Tazuna PTCA dilatation catheter
-
PTCA BALLOON SAPPHIRE
Sapphire II NC
Enhanced distal Z-Tip with advanced laser welding technology for “ZERO” transition with conventional steerable guidewires

Coronary Dilatation Catheter
True controlled compliance
and ultimate crossability for a
Wide Spectrum of Vessels
Crossing Profile (Ø3.0 mm)
Minimal Balloon Growth and Sizing Accuracy
Broad Range of Sizes
G-70-0681 Rev03
Technical Specifications Available Configurations Product DownloadsTechnical Specifications
Catheter Type Rapid Exchange Proximal Shaft Diameter 2.0F Distal Shaft Diameter 2.36F (Ø1.75 mm – 2.0 mm); 2.55F (Ø2.25 mm – 3.5 mm); 2.6F (Ø3.75 mm – 5.0 mm) Catheter Working Length 140 cm Leading Tip Length 1.5 mm (Ø1.75 mm); 2.0 mm (Ø2.0 mm – 3.0 mm); 2.5 mm (Ø3.25 mm – 5.0mm) Balloon Material Nylon Balloon Folds 3 (Ø1.75 mm – 3.0 mm); 5 (Ø3.25 mm – 5. 0 mm) Compliance Controlled-compliant Crossing Profile 0.0336” (Ø3.0 mm) Marker Bands 2 Coating Hydrophilic (distal tip to guidewire exit port), Hydrophobic (guidewire lumen) Nominal Pressure 12 atm Rated Burst Pressure 20 atm (Ø1.75 mm – 4.0 mm); 18 atm (Ø4.5 mm – 5.0 mm) Guiding Catheter Compatibility 5F (1.75 mm – 4.0 mm), 6F (4.5 mm – 5.0 mm) Schematic
Compliance Chart
Pressure Balloon Diameter (Ø in mm) (atm) 1.75 2.0 2.25 2.5 2.75 3.0 3.25 3.5 3.75 4.0 4.5 5.0 6 1.68 1.90 2.14 2.40 2.61 2.86 3.10 3.33 3.54 3.79 4.26 4.70 8 1.70 1.93 2.17 2.44 2.66 2.91 3.15 3.39 3.61 3.86 4.34 4.80 10 1.73 1.97 2.21 2.47 2.70 2.95 3.20 3.44 3.68 3.93 4.42 4.90 12 (NOM)* 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.50 5.00 14 1.77 2.03 2.29 2.53 2.80 3.05 3.30 3.56 3.82 4.07 4.58 5.10 16 1.80 2.07 2.33 2.56 2.84 3.09 3.35 3.61 3.89 4.14 4.66 5.20 18 (RBP)** 1.82 2.10 2.36 2.60 2.89 3.14 3.40 3.67 3.96 4.21 4.74 5.30 20 (RBP)** 1.84 2.13 2.40 2.63 2.93 3.18 3.45 3.72 4.03 4.27 4.82 5.40 22 1.87 2.16 2.44 2.66 2.98 3.23 3.50 3.78 4.10 4.34 4.90 5.49 24 1.89 2.20 2.48 2.69 3.02 3.27 3.55 3.83 4.17 4.41 4.98 5.59 26 1.92 2.23 2.51 2.72 3.07 3.32 3.59 3.89 4.24 4.48 5.06 5.69 -
PTCA BALLOON TRACK
TREK™ Coronary Dilatation Catheter’s unique design provides smooth transitions from hub to tip.
- Transition less tip
- Flexible distal shaft
- Multi-layer CrossFlex²* balloon and Slim Seal** technology.
TECHNICAL INFORMATION
TREK™ & MINI TREK™ CORONARY DILATATION CATHETERS NOMINAL PRESSURE (NP) 8 atm RATED BURST PRESSURE (RBP) 14 atm TIP ENTRY PROFILE 0.017 in (3.00 mm Ø) TIP CROSSING PROFILE 0.021 in average (3.00 mm Ø)
0.023 in maximumFOLDED BALLOON CROSSING PROFILE 0.032 in average (3.00 mm Ø)
0.036 in maximum (3.00 mm Ø)REFOLDED BALLOON CROSSING PROFILE 0.056 in maximum (3.00 mm Ø) RX NOTCH DIAMETER (FOR RX PLATFORM) 2.5 French average (3.00 mm Ø)
2.7 French maximum (all Ø)TIP LENGTH <3 mm BALLOON MATERIAL Pebax†, semi-compliant MARKER MATERIAL Flexible Tungsten/Pebax‡ CATHETER LENGTH 145 cm BALLOON COATING Hydrophilic MINIMUM GUIDE CATHETER 5 French (1.20 mm – 4.00 mm Ø)
6 French (4.50 mm & 5.00 mm Ø)MAXIMUM GUIDE WIRE COMPATIBILITY 0.014 in LATEX FREE Yes Caution
CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE. OBSERVE ALL WARNINGS AND PRECAUTIONS NOTED THROUGHOUT THESE INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN COMPLICATIONS.
Indications
Applies to TREK™ RX & OTW 2.25 mm – 5.00 mm sizes only:
The TREK™ RX & OTW Coronary Dilatation Catheters are indicated for:- Balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis, for the purpose of improving myocardial perfusion
- Balloon dilatation of a coronary artery occlusion, for the purpose of restoring coronary flow in patients with ST-segment elevation myocardial infarction
- Balloon dilatation of a stent after implantation
-
PTCA IRON MAN
Explore Abbott’s growing portfolio of Workhorse and Specialty guide wires. … HT IRON MAN, 1001309, Straight, 190, – … of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA) and … Do not withdraw or manipulate the hydrophilic-coated wire in a metal cannula or sharp-edged object.
-
PTFE GRAFT 6*20CM
VascuGraft PTFE vascular prostheses areconstructed of expanded poly-tetra-flour-ethylene (PTFE) material to form a microporous vascular implant with an advanced structure: V-shaped running through pores, pore size 60µm outside and 20µm inside. VascuGraft PTFE features a uniquely flexible, kink-resistant design that is sufficient porous to encourage cellular in-growth, yet offers maximum protection against blood loss, suture pullout, tearing or delamination. VascuGraft PTFE’s technically advanced architecture also provides maximum protection againstkinking or twisting of the prosthesis following implantation. Helix supported grafts include a removable, continuous spiral PTFE monofilament for additional compression resistance. Tapered, short taper and stepped taper configurations are available for use in special hemodynamic conditions.
-
PTFE GUIDEWIRE EMERILD
Rosen Heavy Duty and Amplatz Super Stiff
PTFE-Coated EMERALDTM Guidewires*EMERALD Diagnostic Guidewire is built with performance, endurance and safety. Built to minimize the likelihood of stretching or fracturing.
Super Stiff EMERALD™ Guidewires. PTFE pre-coated guidewire. Pre-coated. Cordis EMERALD™. Diagnostic Guidewires … Please consult your Cordis Catalogue.
Product Description · Enhanced maneuverability · Ability to finger straighten · Proprietary PTFE coating process · Available in multiple shapes and sizes.
Product Description
Intended for percutaneous entry and guidance of catheters, the Cordis EMERALD® Diagnostic Guidewire complements our diagnostic catheter and catheter sheath introducer lines. Performance, endurance and safety are built into each EMERALD™ Guidewire with solid tensile strength to minimize the likelihood of stretching or fracturing.• For percutaneous entry and
guidance of angiographic catheters
• Pre-coated PTFE
• 5 units per package• Atraumatic end
• For percutaneous entry and high
support guidance of angiographic
catheters
• 5 units per package.Established as a Partnership firm in the year 2021 at Shahdara (Delhi, India), we “B & A Enterprises” are a leading Wholesale Trader of a wide range of Guide Wire, Asahi Guide Wire, Introducer Needles, etc. B&A is an Quality and Customer centric organization which believes in excellence in bridging gap between need and medical products. At B&A we deliver outstanding products across 5 key medical products domain: Cardiology, Nephrology, Urology, Neurology and Radiology. Our medical products bridge the gap between the constant need for quality and the increasing demand for savings. Our product portfolio is a comprehensive offering of clinician-preference, cost-efficient products, and physician-preferred items with low clinical differentiation, helping providers improve the bottom line while delivering high-quality care. Because we work from the acute channel to the home, we’re uniquely positioned to stay ahead, finding product efficiencies that move care forward.
-
PULSE OXIMETER
Key Features- One Button operation
Average Heart Rate
Blood Oxygen saturation level
Low Battery indiactor
Finger Opening
Battery Cover
Heart Rate Line Graph
Lanyard Loop Hole -
QUANTUM MEVERICK BALLOON CATHETER
BOSTON SCIENTIFIC
QUANTUM MEVERICK
BALLOON CATHETER
Maverick2

PTCA Balloon Catheters
Maverick2 TM Balloon Catheter technologies deliver the exceptional performance needed to succeed in demanding cases.Maverick2 Balloon Catheter technologies deliver the exceptional performance needed to succeed in demanding cases.
Explore
Product DetailsProduct Details
Maverick2 Over-The-Wire Balloon Catheter
The balloon catheter that’s ready for whatever you encounter.
- Proprietary laser bonded technology creates an extraordinary TrakTip™ Design and precise, smooth bonds throughout the shaft
- Push coil design and improved distal flexibility for enhanced trackability
- Our 1.5 and 2.0mm SoftLEAP™ Balloons offer enhanced crossability
Maverick2 Monorail™ Balloon Catheter
Greater performance for greater demands.
- Enhanced Shaft Construction: Full-length hypotube construction designed to deliver powerful push for tortuous anatomy and tight lesions
- Outstanding Crossability: Laser bonding technology; seamless and flexible transitions designed for excellent cross and track
- Flexible TrakTip Design: Intended to provide excellent flexibility for navigating through tight lesions and tortuous anatomy
- Excellent Trackability: Low-profile, transitionless tapered distal shaft designed to provide balanced stiffness transition for superb push and track
- Corewire intended to provide outstanding mid-shaft support
Maverick XL Monorail Balloon Catheter
Built for big challenges.
- Widest Range of Diameters: The Maverick XL Balloon Catheter joins the Maverick™ ² Monorail Balloon Catheter to provide the broadest size offering of any coronary balloon catheter line (1.5-6.0mm diameters). Maverick XL Balloon diameters include: 4.0, 4.5, 5.0, 5.5, and 6.0mm
- Laser bonding-smooth transitions designed for excellent crossability and trackability; TrakTip Design-smooth taper and flexibility intended to enhance negotiation of tortuous anatomy; Pebax™ Distal Shaft-Enhanced flexibility intended to improve trackability
- 150cm Shaft for Bypass Grafts: Full-length polymer/corewire construction designed to reduce deflation times
- 6F Guide Compatibility: For versatility and convenience to use your guide catheter of choice
-
-
RADIFOCUS INTRODUCER SHEATH
Radifocus™ Introducer II Standard Kit A
Introducer Sheath (FEMORAL)
Kit of vascular introducer with hemostatic valve with excellent blood tightness,
easy and non traumatic vessel insertion, patented valve design for a unique
features package.- Total Integrated Fit (TIF) tip tapering: tapering design at the tip of the sheath and dilator to facilitate smooth penetration
- Cross-cut hemostasis valve to avoid blood reflux and air aspiration
- Thin radiopaque sheath with anti-kinking sleeve for easy catheter handling
- Snap-on/click-off dilator lock prevents dilator back-out during insertion and allows one-hand unlocking
- Wide variety of kit variations providing all elements for quick vessel access: 4-11 Fr sheaths, 5-16 cm lengths, Surf lash needle
General specifications
Sheath length 10 cm Mini guidewire Plastic Straight and Angled
0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type; 0.035″ (0.89 mm) for all others
45 cmEntry needle Plastic IV Catheter – 18G x 2 ½” (1.2 x 64 mm),
except for 4 Fr with 45 cm straight mini guidewire: 20G x 2″ (0.9 x 51 mm)
2.5 ml syringe is includedGuidewire compatibility 0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type
0.035″ (0.89 mm) for all othersPackaging Tray A Kit content Sheath, dilator, plastic mini guidewire and plastic IV catheter (entry needle) Item specifications
Inner diameter Mini guidewire type 45 cm angled 45 cm straight 4 Fr RS+A40K10AQ RS+A40G10SQ 4 Fr RS*A40G10SQ RS*A40G05SQ 4 Fr RS*A40K10SQ RS*A40G07SQ 5 Fr RS*A50K10AQ RS*A50G07SQ 5 Fr RS+A50K10AQ RS+A50K10SQ 6 Fr RS+A60K10AQ RS+A60K10SQ 6 Fr RS*A60K10AQ RS*A60G07SQ 6 Fr — RS*A60G16SQZ 6 Fr — RS*A60K10SQ 6 Fr — RS+A50K10SQ 7 Fr — RS+A70K10SQ 7 Fr — RS*A70G07SQ 7 Fr — RS*A70K10SQ 8 Fr — RS+A80K10SQ 8 Fr — RS*A80K10SQ 9 Fr — RS*A90K10SQ 10 Fr — RS*A10K10SQ 11 Fr — RS*A11K10SQ A Kit includes: introducer sheath, dilator, mini Guide wire, entry venous catheter, 2.5 cc syringe
B Kit includes: introducer sheath, dilator, mini Guide wire
C Kit includes: introducer sheath, dilator
R Kit includes: introducer sheath, dilator, mini Guide wire, 18 G x 2 3/4” / 1.2 x 70 mm entry metallic needle
Other code numbers are available on special demand. For any further information, please contact your Terumo local representative
Units per box: 5 for kits in tray and 10 for kits in pouch. -
RADIFOCUS REDIAL SHEATH
Providing you the best range of Terumo Radifocus Radial Introducer Sheath and Cordis Femoral Introducer Sheath with effective & timely delivery.
The radial artery access sheath is used to gain arterial access and facilitate the insertion of catheters or other equipment for diagnostic and vascular interventions.
- The Cordis AVANTI®+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI®+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates procedural flexibility. It stays in place and allows patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and helps to minimize damage upon entry.
As part of the circulatory system, the radial artery supplies blood from the heart to the forearm.
Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.
-
-
RADIFOCUS™ GUIDE WIRE M STANDARD TYPE HYDROPHILIC 150/260CM
Description
Radifocus™ Guide Wire M Standard Type Hydrophilic 150Cms
Radifocus™ Guide Wire M Standard Type Hydrophilic 260Cms
AVAILABLE SIZE – 0.025″, 0.032″, 0.035″, 0.038″
SHAPE- STRAIGTH I J TIPLENGTH – 150CM , 260CM Radifocus Guide Wire M Standard type is a Nitinol hydrophilic guide wire covered with polyurethane containing tungsten and a hydrophilic polymer coating (M Coat) for vessel access, lesion crossing and device support.
Designed to direct a catheter to the desired anatomical location in the vascular system (peripheral, cerebral as well as coronary vasculature) during diagnostic or interventional procedures.Characteristics
- Highly flexible, tapered tip for atraumatic and controlled navigation through vessels
- M Coat hydrophilic coating for low friction endovascular steerability and trackability
- Radiopaque polyurethane jacket for good fluoroscopic visibility and controlled navigation
- Superelastic Nitinol core:
- features adaptable shape memory and high flexibility
- prevents kinking for swift device exchange
- One-piece construction with one-to-one torque transmission for predictable navigation
- Rounded, atraumatic tip for the prevention of vessel trauma and low friction guidewire insertion
COMPANY – TERUMO
SIZE – 0.025″, 0.032″, 0.035″, 0.038″
PRODUCT TYPE – GUIDE WIRE
RETURN POLICY
THIS ITEM ISN’T ELIGIBLE FOR RETURN.
-
REDIFOCUS GUIDE WIRE 260
Description
Radifocus TM Guide Wire M Standard type is a Nitinol hydrophilic guide wire covered with polyurethane containing tungsten and a hydrophilic polymer coating (M Coat) for vessel access, lesion crossing and device support.
Designed to direct a catheter to the desired anatomical location in the vascular system (peripheral, cerebral as well as coronary vasculature) during diagnostic or interventional procedures.Characteristics
- Highly flexible, tapered tip for atraumatic and controlled navigation through vessels
- M Coat hydrophilic coating for low friction endovascular steerability and trackability
- Radiopaque polyurethane jacket for good fluoroscopic visibility and controlled navigation
- Superelastic Nitinol core:
- features adaptable shape memory and high flexibility
- prevents kinking for swift device exchange
- One-piece construction with one-to-one torque transmission for predictable navigation
- Rounded, atraumatic tip for the prevention of vessel trauma and low friction guidewire insertion
General specifications
Core material Nitinol Radiopaque jacket Polyurethane layer containing tungsten Hydrophilic coating M Coat Guidewire diameters 0.018″ (0.46 mm + 0.02 mm)* / 0.025″ (0.64 mm + 0.00 mm)* / 0.032″ (0.81 mm + 0.00 mm)* /
0.035″ (0.89 mm + 0.01 mm)* / 0.038″ (0.97 mm + 0.02 mm)*Guidewire lengths 50 cm / 80 cm / 120 cm / 150 cm / 180 cm / 220 cm / 260 cm/ 300 cm / 400 cm / 450 cm Distal flexible lengths 1 cm / 3 cm / 5 cm / 8 cm Distal curves Straight / Angled / 1.5 mm J shape / 3 mm J shape Units per box 5 Item specifications
Product code Wire type Outer diameter Length Flexible tip length curve Tip shape RF-GA18053M Standard 0.018″ (0.46 mm + 0.02 mm)* 50 cm 3 cm Angled RF*GS18183M Standard 0.018″ (0.46 mm + 0.02 mm)* 80 cm 3 cm Straight RF*GA18153M Standard 0.018″ (0.46 mm + 0.02 mm)* 150 cm 3 cm Angled RF-GA18153M Standard 0.018″ (0.46 mm + 0.02 mm)* 150 cm 3 cm Angled RF*GS18153M Standard 0.018″ (0.46 mm + 0.02 mm)* 150 cm 3 cm Straight RF-GS18153M Standard 0.018″ (0.46 mm + 0.02 mm)* 150 cm 3 cm Straight RF*GA18183M Standard 0.018″ (0.46 mm + 0.02 mm)* 180 cm 3 cm Angled RF-GA18183M Standard 0.018″ (0.46 mm + 0.02 mm)* 180 cm 3 cm Angled RF-GS18183M Standard 0.018″ (0.46 mm + 0.02 mm)* 180 cm 3 cm Straight RF-GA18223M Standard 0.018″ (0.46 mm + 0.02 mm)* 220 cm 3 cm Angled RF-GA18263M Standard 0.018″ (0.46 mm + 0.02 mm)* 260 cm 3 cm Angled RF*GA18263M Standard 0.018″ (0.46 mm + 0.02 mm)* 260 cm 3 cm Angled RF*GS18263M Standard 0.018″ (0.46 mm + 0.02 mm)* 260 cm 3 cm Straight RF-GS18263M Standard 0.018″ (0.46 mm + 0.02 mm)* 260 cm 3 cm Straight RF-GA25053M Standard 0.025″ (0.64 mm + 0.00 mm)* 50 cm 3 cm Angled RF-GA25123M Standard 0.025″ (0.64 mm + 0.00 mm)* 120 cm 3 cm Angled RF-GS25123M Standard 0.025″ (0.64 mm + 0.00 mm)* 120 cm 3 cm Straight RF*GA25153M Standard 0.025″ (0.64 mm + 0.00 mm)* 150 cm 3 cm Angled RF-GA25153M Standard 0.025″ (0.64 mm + 0.00 mm)* 150 cm 3 cm Angled RF-GS25153M Standard 0.025″ (0.64 mm + 0.00 mm)* 150 cm 3 cm Straight RF*GS25153M Standard 0.025″ (0.64 mm + 0.00 mm)* 150 cm 3 cm Straight RF-GA25183M Standard 0.025″ (0.64 mm + 0.00 mm)* 180 cm 3 cm Angled RF*GA25183M Standard 0.025″ (0.64 mm + 0.00 mm)* 180 cm 3 cm Angled RF-GS25183M Standard 0.025″ (0.64 mm + 0.00 mm)* 180 cm 3 cm Straight RF*GA25263M Standard 0.025″ (0.64 mm + 0.00 mm)* 260 cm 3 cm Angled RF-GA25263M Standard 0.025″ (0.64 mm + 0.00 mm)* 260 cm 3 cm Angled RF-GS25263M Standard 0.025″ (0.64 mm + 0.00 mm)* 260 cm 3 cm Straight RF*GS25263M Standard 0.025″ (0.64 mm + 0.00 mm)* 260 cm 3 cm Straight RF-GA32123M Standard 0.032″ (0.81 mm + 0.00 mm)* 120 cm 3 cm Straight RF-GS32123M Standard 0.032″ (0.81 mm + 0.00 mm)* 120 cm 3 cm Straight RF*GA32153M Standard 0.032″ (0.81 mm + 0.00 mm)* 150 cm 3 cm Angled RF-GA32153M Standard 0.032″ (0.81 mm + 0.00 mm)* 150 cm 3 cm Angled RF-GS32153M Standard 0.032″ (0.81 mm + 0.00 mm)* 150 cm 3 cm Straight RF*GS32153M Standard 0.032″ (0.81 mm + 0.00 mm)* 150 cm 3 cm Straight RF*GA32183M Standard 0.032″ (0.81 mm + 0.00 mm)* 180 cm 3 cm Angled RF-GA32183M Standard 0.032″ (0.81 mm + 0.00 mm)* 180 cm 3 cm Angled RF-GS32183M Standard 0.032″ (0.81 mm + 0.00 mm)* 180 cm 3 cm Straight RF-GA32263M Standard 0.032″ (0.81 mm + 0.00 mm)* 260 cm 3 cm Angled RF*GA32263M Standard 0.032″ (0.81 mm + 0.00 mm)* 260 cm 3 cm Angled RF*GS32263M Standard 0.032″ (0.81 mm + 0.00 mm)* 260 cm 3 cm Straight RF-GS32263M Standard 0.032″ (0.81 mm + 0.00 mm)* 260 cm 3 cm Straight RF-GA35053M Standard 0.035″ (0.89 mm + 0.01 mm)* 50 cm 3 cm Angled RF*GA35083M Standard 0.035″ (0.89 mm + 0.01 mm)* 50 cm 3 cm Angled RF-GA35083M Standard 0.035″ (0.89 mm + 0.01 mm)* 80 cm 3 cm Angled RF-GA35123M Standard 0.035″ (0.89 mm + 0.01 mm)* 120 cm 3 cm Angled RF*GA35123M Standard 0.035″ (0.89 mm + 0.01 mm)* 120 cm 3 cm Angled RF-GS35123M Standard 0.035″ (0.89 mm + 0.01 mm)* 120 cm 3 cm Straight RF-GA35151M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 1 cm Angled RF-GS35151M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 1 cm Straight RF*GA35153M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 3 cm Angled RF*GR35153M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 3 cm J Angled (1.5 mm) RF*GB35153M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 3 cm J Angled (3 mm) RF*GS35153M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 3 cm Straight RF*GS35153M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 3 cm Straight RF-GA35155M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 5 cm Angled RF*GA35155M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 5 cm Angled RF-GS35155M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 5 cm Straight RF*GA35158M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 8 cm Angled RF-GA35158M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 8 cm Angled RF-GS35158M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 8 cm Straight RF*GS35158M Standard 0.035″ (0.89 mm + 0.01 mm)* 150 cm 8 cm Straight RF-GA35181M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 1 cm Angled RF-GS35181M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 1 cm Straight RF*GA35183M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 3 cm Angled RF*GR35183M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 3 cm J Angled (1.5 mm) RF-GS35183M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 3 cm Straight RF*GS35183M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 3 cm Straight RF*PS35183M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 3 cm Straight RF*GA35188M Standard 0.035″ (0.89 mm + 0.01 mm)* 180 cm 8 cm Angled RF*GA35223M Standard 0.035″ (0.89 mm + 0.01 mm)* 220 cm 3 cm Angled RF-GA35223M Standard 0.035″ (0.89 mm + 0.01 mm)* 220 cm 3 cm Angled RF-GS35223M Standard 0.035″ (0.89 mm + 0.01 mm)* 220 cm 3 cm Straight RF-GA35261M Standard 0.035″ (0.89 mm + 0.01 mm)* 260 cm 1 cm Angled RF-GS35261M Standard 0.035″ (0.89 mm + 0.01 mm)* 260 cm 1 cm Straight RF*GA35263M Standard 0.035″ (0.89 mm + 0.01 mm)* 260 cm 3 cm Angled RF*GR35263M Standard 0.035″ (0.89 mm + 0.01 mm)* 260 cm 3 cm J Angled (1.5 mm) RF*GS35263M Standard 0.035″ (0.89 mm + 0.01 mm)* 260 cm 3 cm Straight RF-GS35263M Standard 0.035″ (0.89 mm + 0.01 mm)* 260 cm 3 cm Straight RF*GS35263M Standard 0.035″ (0.89 mm + 0.01 mm)* 260 cm 3 cm Straight RF-GA35303M Standard 0.035″ (0.89 mm + 0.01 mm)* 300 cm 3 cm Angled RF*GA35303M Standard 0.035″ (0.89 mm + 0.01 mm)* 300 cm 3 cm Angled RF*GS35303M Standard 0.035″ (0.89 mm + 0.01 mm)* 300 cm 3 cm Straight RF*GA35403M Standard 0.035″ (0.89 mm + 0.01 mm)* 400 cm 3 cm Angled RF*GS35403M Standard 0.035″ (0.89 mm + 0.01 mm)* 400 cm 3 cm Straight RF*GA35453M Standard 0.035″ (0.89 mm + 0.01 mm)* 450 cm 3 cm Angled RF*GS35453M Standard 0.035″ (0.89 mm + 0.01 mm)* 450 cm 3 cm Straight RF-GA38151M Standard 0.038″ (0.97 mm + 0.02 mm)* 150 cm 1 cm Angled RF*GA38153M Standard 0.038″ (0.97 mm + 0.02 mm)* 150 cm 3 cm Angled RF-GS38153M Standard 0.038″ (0.97 mm + 0.02 mm)* 150 cm 3 cm Straight RF*GS38153M Standard 0.038″ (0.97 mm + 0.02 mm)* 150 cm 3 cm Straight RF*PS38153M Standard 0.038″ (0.97 mm + 0.02 mm)* 150 cm 3 cm Straight RF-GA38183M Standard 0.038″ (0.97 mm + 0.02 mm)* 180 cm 3 cm Angled RF*GA38183M Standard 0.038″ (0.97 mm + 0.02 mm)* 180 cm 3 cm Angled RF-GS38183M Standard 0.038″ (0.97 mm + 0.02 mm)* 180 cm 3 cm Straight RF-GA38223M Standard 0.038″ (0.97 mm + 0.02 mm)* 220 cm 3 cm Angled RF*GA38263M Standard 0.038″ (0.97 mm + 0.02 mm)* 260 cm 3 cm Angled RF-GA38263M Standard 0.038″ (0.97 mm + 0.02 mm)* 260 cm 3 cm Angled RF*GS38263M Standard 0.038″ (0.97 mm + 0.02 mm)* 260 cm 3 cm Straight RF-GS38263M Standard 0.038″ (0.97 mm + 0.02 mm)* 260 cm 3 cm Straight -
Reliant Button Switch Pencil Ref vl2610
he products we procure are of best quality and are as per our detailed guidelines. The entire process is performed under the vigilance of best-trained professionals by using finest quality raw material, latest machines and techniques.
-
RESOLUTE INTEGRITY STENT
Resolute Onyx DES
for coronary artery disease
Resolute Onyx™ is a drug-eluting stent (DES) that’s different by design, optimised for complex PCI, and proven safe and effective in real-world, high bleeding risk patients on 1-month dual antiplatelet therapy (DAPT).1
Resolute Onyx DES is different by design to address your DES needs and a wide range of patient anatomies. It features:
- Best-in-class deliver ability
- Enhanced visibility with thinner struts
- Smooth side branch access
- Fast healing
- The broadest diameter range
Best-in-class deliverability
Single-wire design
Resolute Onyx DES is made from a single wire, which gives it a fluid range of motion and provides the flexibility needed for best-in-class deliverability.2

Sinusoid-formed wire

Helical wrap

Laser-fused
Competitive comparison
Resolute Onyx DES is more deliverable than laser-cut SYNERGY™* XD and XIENCE Skypoint™*, which are stiffer.
Deliverability comparison — 3.0 mm DES2
(Lower is better)

Enhanced visibility with thinner struts
Platinum-iridium core within Resolute Onyx DES increases visibility for accurate stent placement without compromising strut thickness.2Average visibility comparison2
(Higher is better)

- Cobalt alloy shell
- Platinum iridium core

Resolute Onyx cobalt alloy shell and platinum-iridum core
Smooth side branch access
Resolute Onyx DES has round struts to create a smooth passage when accessing the side branch and lower the propensity to catch during bifurcation procedures.2
Strut comparison
Rounded strut cross-section
- Resolute Onyx DES

Square strut cross-section
- SYNERGY™* DES
- XIENCE™* DES

Broadest diameter range
- Complex PCI requires a broad DES size matrix to match a wide range of patient anatomies.
- Resolute Onyx is the only DES with diameters ranging from 2.0 mm to 5.0 mm to treat a broad range of coronary vessel sizes.
Diameter (mm) Stent Length (mm) Maximum Expansion
Capabilities (MSID†) (mm)2.00 8 12 15 18 22 26 30 — — 3.50‡ 2.25 8 12 15 18 22 26 30 34 38 3.50‡ 2.50 8 12 15 18 22 26 30 34 38 3.50‡ 2.75 8 12 15 18 22 26 30 34 38 4.00‡ 3.00 8 12 15 18 22 26 30 34 38 4.00‡ 3.50 8 12 15 18 22 26 30 34 38 5.00‡ 4.00 8 12 15 18 22 26 30 34 38 5.00‡ 4.50 — 12 15 18 22 26 30 — — 6.00‡ 5.00 — 12 15 18 22 26 30 — — 6.00‡ PRODUCT DETAILS
2.00 RONYX20008X RONYX20012X RONYX20015X RONYX20018X RONYX20022X RONYX20026X RONYX20030X N/A N/A 2.25 RONYX22508X RONYX22512X RONYX22515X RONYX22518X RONYX22522X RONYX22526X RONYX22530X RONYX22534X RONYX22538X 2.50 RONYX25008X RONYX25012X RONYX25015X RONYX25018X RONYX25022X RONYX25026X RONYX25030X RONYX25034X RONYX25038X 2.75 RONYX27508X RONYX27512X RONYX27515X RONYX27518X RONYX27522X RONYX27526X RONYX27530X RONYX27534X RONYX27538X 3.00 RONYX30008X RONYX30012X RONYX30015X RONYX30018X RONYX30022X RONYX30026X RONYX30030X RONYX30034X RONYX30038X 3.50 RONYX35008X RONYX35012X RONYX35015X RONYX35015X RONYX35022X RONYX35026X RONYX35030X RONYX35034X RONYX35038X 4.00 RONYX40008X RONYX40012X RONYX40015X RONYX40018X RONYX40022X RONYX40026X RONYX40030X RONYX40034X RONYX40038X 4.50 N/A RONYX45012X RONYX45015X RONYX45018X RONYX45022X RONYX45026X RONYX45030X N/A N/A 5.00 N/A RONYX50012X RONYX50015X RONYX50018X RONYX50022X RONYX50026X RONYX5 -
Reusable Instruments
Reusable medical instruments and devices are products that are sterilized or cleaned for reuse. Advances in medical sciences and, in particular, minimally invasive surgical and diagnostic procedures, have stimulated the development of new and improved medical devices. This is due to developments in engineering and material sciences.
-
RINATO
RINATO
Front line guide wire with flexible tip and moderate core wire support.
Excellent maneuverability with good support for device delivery and atraumatic tip for stress-free operation.
Product Spec
Tip Load 0.8gf Tip Shape Straight / J-shape Radiopaque Length 3cm Coating Silicone+Hydrophilic Usable Length 180cm / 300cm Structure 
Category Order Information
Product Name Catalog No. Tip Shape Usable Length Outer Diameter Tip Load Coil Length Radiopaque Length Coating Coating Length Rinato/PROWATER AGH146000 Straight 180cm 0.36mm (0.014″) 0.8gf 20cm 3cm Silicone+Hydrophilic 200mm Rinato/PROWATER AGH146000J J 180cm 0.36mm (0.014″) 0.8gf 20cm 3cm Silicone+Hydrophilic 200mm Rinato/PROWATER AGH146300 Straight 300cm 0.36mm (0.014″) 0.8gf 20cm 3cm Silicone+Hydrophilic 200mm -
-
RUMI II Koh-Efficient – Uterine Manipulator
RUMI II Koh-Efficient – Uterine Manipulator
The Koh-Efficient system combines the Koh Cup and pneumo-occlusion balloon into one device. The system loads easily onto the RUMI II for rapid and accurate clinical positioning. Koh-Efficient creates a margin of safety by providing a visual landmark and backstop for full circumferential colpotomy, as well as distancing the ureters during the incision. Once in position, the Koh-Efficient allows for full articulation at the cervix. This sterile, single-use device is available in four sizes; fit to the cervix is important for the margin of safety.Parts & Accessories
CPO-6 Colpo-Pneumo Occluders, Sterile, Single-Use (6/Box) KC-RUMI-25 Rumi II/Koh-Efficient for Electrosurgery, 2.5 cm (5/Box) KC-RUMI-30 Rumi II/Koh-Efficient for Electrosurgery, 3.0 cm (5/Box) KC-RUMI-35 Rumi II/Koh-Efficient for Electrosurgery, 3.5 cm (5/Box) KC-RUMI-40 Rumi II/Koh-Efficient for Electrosurgery, 4.0 cm (5/Box) KCP-30-2 Ultem Polymeric Resin Koh Cup for Electrosurgery, (2) Nonsterile, 3 cm KCP-35-2 Ultem Polymeric Resin Koh Cup for Electrosurgery, (2) Nonsterile, 3.5 cm KCP-40-2 Ultem Polymeric Resin Koh Cup for Electrosurgery, (2) Nonsterile, 4 cm KCS-RUMI-25 Stainless Steel Capped Rumi II/Koh-Efficient for Harmonic Scalpel/Laser, 2.5 cm (5/Box) KCS-RUMI-30 Stainless Steel Capped Rumi II/Koh-Efficient for Harmonic Scalpel/Laser, 3.0 cm (5/Box) KCS-RUMI-35 Stainless Steel Capped Rumi II/Koh-Efficient for Harmonic Scalpel/Laser, 3.5 cm (5/Box) KCS-RUMI-40 Stainless Steel Capped Rumi II/Koh-Efficient for Harmonic Scalpel/Laser, 4.0 cm (5/Box) KCS-30 Stainless Steel Koh Cup for Harmonic Scalpel/Laser, (1) Nonsterile, 3 cm KCS-35 Stainless Steel Koh Cup for Harmonic Scalpel/Laser, (1) Nonsterile, 3.5 cm KCS-40 Stainless Steel Koh Cup for Harmonic Scalpel/Laser, (1) Nonsterile, 4 cm -
RUNTHROUGH® NS EXTRA FLOPPY(PTCA WIRE)
PRODUCT OVERVIEW
Designed to be your first choice coronary guidewire
The RUNTHROUGH NS Extra Floppy is designed to be an all-in-one workhorse wire with a soft, atraumatic, low tip weight wire that can be used to access most everyday and complex lesions.
NITINOL CORE-TO-TIP DESIGN FOR EXCELLENT TIP DURABILITY
This feature enables a single RUNTHROUGH wire to be used for multiple vessels potentially reducing a facility’s wire usage, saving both time and money.1
DIRECT
JOINT-DUO CORETM TECHNOLOGYInnovative technology enables connection of two different metal characteristics. This seamless fusion of two proven guidewire metals provides 1:1 torque response/steerability, pushability and trackability.1
BALANCE OF HYDROPHILIC AND HYDROPHOBIC
COATING“M-coat” technology hydrophilic coating over the distal 24.8cm of the distal tip enables smooth trackability in the tortuous anatomy while the silicone tip on the distal 2mm provides tactile feedback and system support for device delivery.1
PRODUCT CODES
RUNTHROUGH NS Extra Floppy
Product Code Diameter Length Tip Radiopacity Tip Shape 25-1011 0.014″ 180cm 3cm Straight 25-1013 0.014″ 300cm 3cm Straight 25-9092 0.014″ 150cm N/A N/A The RUNTHROUGH NS Extra Floppy is designed to be an all-in-one workhorse wire with a soft, atraumatic, low tip weight wire that can be used to access most everyday and complex lesions.
GUIDE WIRES are intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA).
Superb seamless joint technology. The direct-joint Runthrough NS series deliver definitive torque response and easier, more flexible steering control.
-
RUNTHROUGH® NS HYPERCOAT (PTCA WIRE)
PRODUCT OVERVIEW
Designed to be your complex coronary wire of choice
Runthrough NS Hype coat is an enhanced hydrophilic guidewire for tortuous, distal lesions and tight stenotic complex lesions.
ENHANCED M-COAT HYDROPHILIC COATING FOR IMPROVED TRACKABILITY
Proprietary enhanced M-coat provides superior wire trackability to reach tortuous distal lesions–comparable to plastic-jacketed wires.
LOW-WEIGHT FLEXIBLE TIP ENGINEERED FOR EASY PROLAPSE
A low tip weight and a highly flexible tip enables easy prolapse in the distal anatomy, which may add to its safety when used in complex PCI.
NITINOL CORE-TO-TIP DESIGN FOR SUPERIOR
DURABILITYThis feature enables a single Runthrough wire to be used for multiple vessels, potentially reducing a facility’s wire usage, saving both time and money.
PRODUCT CODES
RUNTHROUGH NS HYPERCOAT SKUs
Product Code Diameter
(in)Length
(cm)Tip Radiopacity
(cm)Tip Shape 25-3011 0.014″ 180cm 3cm Straight 25-3013 0.014″ 300cm 3cm Straight 25-9092 0.014″ 150cm N/A N/A * 25-9092 is an extension wire to be used with 180cm wires only.REFERENCES
RX ONLY. Refer to the product labels and package insert for complete warnings, potential complications, and instructions for use.
-
RUNTHRROUGHT NS FLOPPY (PTCA WIRE)
Product Description
Product OverviewDesigned to be your first choice coronary guidewireThe RUNTHROUGH NS Extra Floppy is designed to be an all-in-one workhorse wire with a soft, atraumatic, low tip weight wire that can be used to access most everyday and complex lesions.
Established in the year 2010 at Delhi, (India), we “Marlins Medico” are a Proprietorship Firm, engaged in wholesale trading, importing and exporting the finest quality cardiology, nephrology/surgical in more division product like Redifocus Sheath, Surgical Catheter, Guide Wire, etc. Under the guidance of our mentor “Sakshi Patel (Senior Sales Manager)”, we have reached on top position in the industry. We export our products to china, Indonesia, Singapore, Netherland, Turkey, Greece, etc. as well as import from china, turkey, Greece.
Runthrough NS represents your PTCA guidewire family to cross any workhorse or challenging case.
Runthrough NS guidewire family is intended for use in interventional cardiology procedures.
Characteristics
The Duo Core direct-joint technology of Runthrough NS family delivers definitive torque response and easier, more flexible steering control1
- The directly jointed stainless steel and nitinol shaft provides a superior torque transmission2
- The nitinol alloy core to tip ensures a superior durable shaping memory3
- The “M Coat” hydrophilic coating enables smooth manipulation even in tortuous anatomy
Guidewire segmentation map


General specifications
Diameter 0.014″ (0.36 mm + 0.00 mm)* Wire length 180 cm Radiopaque length 3 cm Distal shape Straight Distal coating Hydrophilic Proximal coating PTFE *Nominal OD + upper tolerance, reflecting Maximal ODItem specifications
Item Clinical
applicationTip load (gf) Tip shaping part Rail support Coating Distal tip coating Item reference RunthroughTM NS Extra Floppy Workhorse 0.6 gf 10 mm Extra support Hydrophilic 2 mm silicone TW-AS418XA RunthroughTM NS Floppy Workhorse 1 gf 10 mm Light Hydrophilic 2 mm silicone TW-AS418FA RunthroughTM NS Hypercoat Crossing 1 gf 14 mm Extra support Enhanced hydrophilic - TW-DS418FH RunthroughTM NS Intermediate Crossing 3.6 gf 10 mm Extra support Hydrophilic 2 mm silicone TW-DS418IA Item Clinical application Item reference RunthroughTM NS Extension Wire Extension TW-JJ415 Please quote above item reference codes when placing an order.
References
1 Compared to most contemporary guidewires. Goldberg at al.; Guidewires – Round table expert, touch Briefings 2008.
2 Compared to competition, with non Duo Core guidewires. Goldberg at al.; Guidewires – Round table expert, touch Briefings 2008.
3 Compared to SUS material properties. Goldberg at al.; Guidewires – Round table expert, touch Briefings 2008. -
RX Acculink Carotid Stent System
RX Acculink
Carotid Stent System
Accuracy and Flexibility
Innovative design for accuracy, flexibility and conformability.
Innovative Design
- Offers high coverage to reduce embolic risk
- Both straight and tapered stent options
- Tapered design allows natural diameter match and avoids excessive radial force in smaller diameters1
- Nitinol material provides strength, crush resistance, conformability and flexibility
Deliverability and Usability
- Rapid exchange delivery system for single operator use and fast exchanges
- Unique handle allows easy, single-handed deployment while retracting sheath
- Finger-pull deployment allows accurate stent placement
Low Profile
- Deliverable .014″ low-profile system
- 6F sheath/8F guiding catheter compatible
- Compatible with 100 cm guiding catheters and sheaths
- van den Berg JC, How Self Expanding Bare-Metal Stent Design Can Affect Procedural Results. Endovascular Today. 2018; volume 6
speicification
RX ACCULINK® CAROTID STENT SYSTEM STENT DIAMETER STOCK NUMBER ICA REFERENCE VESSEL DIAMETER CCA REFERENCE VESSEL DIAMETER (MM) 20 (MM) 30 (MM) 40 (MM) 5.0 1011337-20 1011337-30 1011337-40 3.6-4.5 N/A 6.0 1011338-20 1011338-30 1011338-40 4.3-5.4 N/A 7.0 1011339-20 1011339-30 1011339-40 5.0-6.4 N/A 8.0 1011340-20 1011340-30 1011340-40 5.7-7.3 N/A 9.0 1011341-20 1011341-30 1011341-40 6.4-8.2 N/A 10.0 1011342-20 1011342-30 1011342-40 7.1-9.1 N/A 6.0-8.0 taper N/A 1011343-30 1011343-40 4.3-5.4 5.7-7.3 7.0-10.0 taper N/A 1011344-30 1011344-40 5.0-6.4 7.1-9.1 -
SeeClear Surgical Smoke Evacuation System
SeeClear Surgical Smoke Evacuation System
SeeClear is a passive, disposable, multistage filter system that traps smoke, particulates and aerosolized pathogens, while absorbing odors and chemical toxins. No vacuum pump is required, so SeeClear functions silently, removing surgical plume and providing a clear view of the surgical field. Everything is included, enabling one easy connection to the trocar side port without any additional tubing. The elevated intraperitoneal pressure pushes out the smoke along with the CO2. Flow rates are preset to optimize smoke removal without losing pneumoperitoneum.
Parts & Accessories
SC062500 SeeClear Maximum Flow Rate: 6.0 L/min. at 15 mm HG pressure differential (10/Box) SC082500 SeeClear Maximum Flow Rate: 8.0 L/min. at 15 mm HG pressure differential (10/Box) -
SERAFIT
Serafit® is a braided absorbable suture, which is extremely pliable and allows a smooth passage of the thread through the tissue during suture placement with minimum sawing effect. It can be tied reliably, even in areas containing a good deal of blood or tissue secretions, and ensures knot security. SERAFIT® is available in a special form with patented suture stiffening for use in minimally invasive surgery.
-
SHINOBI GUIDEWIRE (STABILIZER)
Product Description
Cordis offers a complete platform of steerable guidewires for choosing the right guidewire given a specific clinical situation. The portfolio includes radiolucent and radiopaque wires, various support wires and sub-total occlusion wires, for highly stenosed lesions. All Cordis Guidewires possess important features required to successfully treat all the complex and challenging lesions:
- The DURAGLIDE™ Coated Sleeve provides consistent lubricity throughout the entire procedure, to enable smooth delivery of multiple devices.
- The One-Piece stainless steel core wire design optimizes the transmission of torque to the distal tip of the wire for optimal control.
- The broad transition at the tip provides optimal control of the wire to selectively steer to a specific vessel location.
- The Flex-Joint bond adds strength and flexibility to the distal core wire transition for enhanced trackability in tortuous anatomy.
- The PTFE spray coat minimizes friction on the proximal end for smooth device delivery.
Cordis offers a complete platform of .014″ steerable guidewires, including
radiolucent and radiopaque wires, various support wires and total
occlusion wires.REFLEX®
Light Support Wire
• An ultra-thin .0067″ core wire combined with Cordis’ silicone based SLX™ coating
give the REFLEX® Guidewire its outstanding crossing properties
• 25 cm distal radiopaque coil
• One-piece core construction
• Distal SLX™-lubricant.STABILIZER® / STABILIZER® Marker Wire
Moderate Support / Workhorse Wire
Broad Transition One-Piece Corewire (0.010”) for enhanced linear control
• Flex-Joint bond maintains strength and flexibility of the distal corewire transition
• Duraglide proximal coating and distal PTFE sleeve provide enhanced lubricity
• Balanced support and flexibility for greater guidewire demands
• Available Tip configuration: Supersoft, Soft
• Also available as Stabilizer® Plus and Stabilizer® XS and Stabilizer® Marker Wire
• Stabilizer® Marker Wire is an intermediate support wire for secure lesion
measurement with 6 equally distanced marker bands (15 mm).SHINOBI®
Highly Stenosed Lesion Wire
• Broad Transition One-Piece Core wire (0.007”) for enhanced linear control
• Flex-Joint bond maintains strength and flexibility of the distal core wire transition
• Extended PTFE sleeve over tip provides superior lubricity
• Flexibility with support for modern applications
• Available Tip configuration: Floppy.SHINOBI® Plus
Highly Stenosed Lesion Wire
• Broad Transition One-Piece Core wire (0.010”) for enhanced linear control
• Flex-Joint bond maintains strength and flexibility of the distal core wire transition
• Extended PTFE sleeve over tip provides superior lubricity
• Balanced support and flexibility for greater guidewire demands
• Available Tip configuration: Floppy. -
Skin Closure Solution
The Rapid, Patient-Centric Skin Closure Solution
Absorbable Subcuticular Skin Staple
INSORB staples are placed entirely underneath the surface layer of skin (epidermis). These staples offer clinical benefits, are cost-effective1, and highly patient-centric. Wound care for c-section patients with absorbable staples is similar to care for conventional incision closures, and may even have fewer complications2.
- Eliminate Percutaneous Insult
- Improve Patient Comfort & Cosmesis
- May Result in Less Pain Immediately
Post-op in C-sections1
- Evidence of Reduced Wound
Complications vs. Metal Staples
in C-sections2
-
Skin Stapler
Dermamate is a high quality and low cost single-use skin stapler which is a ready to use, sterile device with ergonomic design. Dermamate is a wide size 35 pin skin stapler having application in abdominal, gynaecological, orthopaedic, and thoracic surgery for skin closure along with a variety of skin closures. Dolphin Skin Staplers are recommended to be used along with our Staple Remover.
-
SLIMPORT LP MRI PORT CHRONOFLE X CATH 6FR
- Small footprint
- Ultra-low profile port design
- Reduces the port placement incision and pocket size
- Large septum simplifies needle insertion
-
Sphere Diposable Inflation Device
- During minimally invasive balloon dilation procedures, the Cook Sphere Inflation Device can be used to inflate the balloon with fluid, to monitor the pressure in the balloon during the procedure, and to deflate the balloon after dilation.
- Used while performing balloon dilation procedures to inflate the balloon, monitor the pressure within the balloon, and deflate the balloon.
-
Spinal Needle
Product Details:
- Spinal needle provides exceptional control when penetrating the dura
- Suitable for spinal anaesthesia
- Aggressive anesthetic distribution upon injection
- High flow rate enables faster Cerebra Spinal Fluid (CSF) flashback
- Clear polycarbonate hub offers easy visualization of CSF or blood
- Conical tip imparts superior tactile feedback
- Sterile product for single use
-
SPRINTER LEGEND PTCA BALLOON
SPRINTER LEGEND 1.25 BALLOON CATHETER
Super Crosser Semi compliant Balloon Dilatation Catheter (RX/OTW)
Sprinter™ Legend™ 1.25 SuperCrosser semicompliant balloon dilatation catheter delivers exceptional crossability to treat today’s challenging lesions.
With innovative crossing technologies and 57 sizes, the Sprinter™ Legend™ RX semicompliant balloon dilatation catheter provides you with the power to cross.
OVERVIEW
During difficult cases, reach for a slim Sprinter™ Legend™ 1.25 mm Super Crosser semi compliant coronary balloon catheter featuring:
- Award-winning* Zerofold technology — no wrapped material and no balloon shoulders
- Low 0.5 mm (0.020 in) crossing profile
- OTW and RX platforms
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
1.25 SPL12506WL SPL12510WL SPL12515WL SPL12520WL Sprinter Legend RX Semi compliant
Balloon Dilatation Catheter
OVERVIEW
Performance You Can Trust
Sprinter™ Legend™ semicompliant balloons help you cross, open, and treat lesions during challenging percutaneous coronary interventions (PCIs), and feature:
- Some of the industry’s lowest crossing profiles1
- Innovative crossing technology
- A broad range of sizes
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
Balloon Diameter (mm)
1.25 SPL12506X SPL12510X SPL12512X SPL12515X 1.50 SPL15006X SPL15010X SPL15012X SPL15015X 2.00 SPL20006X SPL20010X SPL20012X SPL20015X 2.25 SPL22506X SPL22510X SPL22512X SPL22515X 2.50 SPL25006X SPL25010X SPL25012X SPL25015X 2.75 SPL27506X — SPL27512X SPL27515X 3.00 SPL30006X SPL30010X SPL30012X SPL30015X 3.25 — — SPL32512X SPL32515X 3.50 SPL35006X SPL35010X SPL35012X SPL35015X 3.75 — — SPL37512X SPL37515X 4.00 SPL40006X SPL40010X SPL40012X SPL40015X BALLOON LENGTHS 20, 25, AND 30 MM
Balloon Diameter (mm)
1.25 SPL12520X — — 1.50 SPL15020X — — 2.00 SPL20020X SPL20025X SPL20030X 2.25 SPL22520X SPL22525X — 2.50 SPL25020X SPL25025X SPL25030X 2.75 SPL27520X SPL27525X — 3.00 SPL30020X SPL30025X SPL30030X 3.25 SPL32520X — — 3.50 SPL35020X SPL35025X SPL35030X 3.75 SPL37520X — — 4.00 SPL40020X SPL40025X SPL40030X -
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinter™ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinter™ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Selective Dura-Trac coating
- 2.5 mm tip
- FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip





















































