ULTIMATE BROS 3
ULTIMATE BROS 3
ULTIMATEbros 3
Good choice for mixed morphology lesions due to guide wires long hydrophilic coating which maintains high maneuverability, allowing for improved wire manipulation in highly stenosed lesions. Fine shaping improves vessel selectivity and reduces the risk of false lumen expansion. Chronic Total Occlusion indicated.

| TIP LOAD | ![]() |
| TIP RADIOPACITY | 11 cm |
| COATING | HYDROPHILIC* WITH UNCOATED DISTAL TIP Hydrophilic 40 cm – uncoated distal tip |
| TIP SHAPE | ![]() |
Ordering Information
| PRODUCT | CATALOG NO. | TIP SHAPE | LENGTH (CM) | DIAMETER (INCH(MM)) | RADIOPAQUE SEGMENT (CM) | SPRING COIL LENGTH (CM) | COATING |
|---|---|---|---|---|---|---|---|
| ULTIMATEbros 3 | AHW14S003S | Straight | 180 | 0.014 (0.36) | 11 | 11 | HYDROPHILIC* WITH UNCOATED DISTAL TIP Hydrophilic 40 cm – uncoated distal tip |
| ULTIMATEbros 3 300 cm | AHW14S303S | Straight | 300 | 0.014 (0.36) | 11 | 11 | HYDROPHILIC* WITH UNCOATED DISTAL TIP Hydrophilic 40 cm – uncoated distal tip |
Indications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
Related products
-
PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- ​Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
Shaft diameter 1.9 Fr / 0.64Â mm Proximal
2.5 Fr / 0.84 mm Mid
2.6 Fr / 0.86 mm DistalUsable length 145 cm Balloon markers 2 Nominal pressure 12 atm / 1216 kPa Rated burst pressure 22 atm / 2229 kPa (2.0 mm to 4.0 mm)
20 atm / 2026 kPa (4.5 and 5.0 mm)Guidewire compatibility Maximum diameter 0.014″ / 0.36 mm Lesion entry profile 0.43 mm Coating Hydrophilic Item specifications
Ordering Information
Balloon
diameter
(mm) ​Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​ 6 8 12 15 20 25 30 2.00 DC-RM2006HSW DC-RM2008HSW DC-RM2012HHW DC-RM2015HHW DC-RM2020HHW — — 2.25 DC-RM2206HSW DC-RM2208HSW DC-RM2212HHW DC-RM2215HHW DC-RM2220HHW — — 2.50 DC-RM2506HSW DC-RM2508HSW DC-RM2512HHW DC-RM2515HHW DC-RM2520HHW DC-RM2525HHW DC-RM2530HHW 2.75 DC-RM2706HSW DC-RM2708HSW DC-RM2712HHW DC-RM2715HHW DC-RM2720HHW — — 3.00 DC-RM3006HSW DC-RM3008HSW DC-RM3012HHW DC-RM3015HHW DC-RM3020HHW DC-RM3025HHW DC-RM3030HHW 3.25 DC-RM3206HSW DC-RM3208HSW DC-RM3212HHW DC-RM3215HHW DC-RM3220HHW — — 3.50 DC-RM3506HSW DC-RM3508HSW DC-RM3512HHW DC-RM3515HHW DC-RM3520HHW DC-RM3525HHW DC-RM3530HHW 3.75 DC-RM3706HSW DC-RM3708HSW DC-RM3712HHW DC-RM3715HHW DC-RM3720HHW — — 4.00 DC-RM4006HSW DC-RM4008HSW DC-RM4012HHW DC-RM4015HHW DC-RM4020HHW — — 4.50 DC-RM4506HSW DC-RM4508HSW DC-RM4512HSW DC-RM4515HSW — — — 5.00 DC-RM5006HSW DC-RM5008HSW DC-RM5012HSW DC-RM5015HSW — — — Please quote above item reference codes when placing an order.
Balloon Compliance
Balloon
diameter
(mm) ​Pressure (atm) ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2.00 1.58 1.65 1.72 1.79 1.84 1.88 1.92 1.95 1.98 2.00* 2.01 2.03 2.04 2.05 2.06 2.08 2.09 2.10 2.12 2.13** 2.14 2.15 2.17 2.25 1.96 2.01 2.06 2.11 2.14 2.16 2.19 2.21 2.23 2.25* 2.26 2.28 2.29 2.31 2.32 2.34 2.35 2.36 2.38 2.39** 2.41 2.42 2.44 2.50 2.19 2.24 2.30 2.36 2.38 2.41 2.44 2.46 2.48 2.50* 2.52 2.53 2.55 2.56 2.58 2.60 2.61 2.63 2.64 2.66** 2.68 2.69 2.71 2.75 2.43 2.48 2.53 2.59 2.62 2.65 2.67 2.70 2.73 2.75* 2.77 2.79 2.80 2.82 2.84 2.86 2.87 2.89 2.91 2.93** 2.94 2.96 2.98 3.00 2.65 2.71 2.76 2.82 2.85 2.89 2.92 2.95 2.97 3.00* 3.02 3.04 3.06 3.08 3.10 3.11 3.13 3.15 3.17 3.19** 3.21 3.23 3.25 3.25 2.89 2.95 3.01 3.07 3.10 3.14 3.17 3.20 3.22 3.25* 3.27 3.29 3.31 3.33 3.35 3.37 3.39 3.42 3.44 3.46** 3.47 3.48 3.51 3.50 3.13 3.19 3.26 3.32 3.35 3.39 3.42 3.45 3.47 3.50* 3.52 3.54 3.57 3.59 3.61 3.63 3.65 3.68 3.70 3.72** 3.74 3.74 3.76 3.75 3.37 3.44 3.50 3.56 3.60 3.63 3.66 3.69 3.72 3.75* 3.77 3.80 3.82 3.84 3.86 3.88 3.90 3.92 3.94 3.96** 3.98 3.99 4.01 4.00 3.58 3.65 3.72 3.79 3.83 3.87 3.90 3.94 3.97 4.00* 4.03 4.05 4.07 4.09 4.11 4.13 4.15 4.17 4.19 4.21** 4.23 4.26 4.28 4.50 4.02 4.10 4.19 4.28 4.32 4.37 4.40 4.44 4.47 4.50* 4.53 4.56 4.59 4.63 4.66 4.68 4.71 4.75** 4.78 4.81 4.84 4.87 4.91 5.00 4.52 4.59 4.67 4.75 4.80 4.85 4.89 4.93 4.96 5.00* 5.03 5.07 5.10 5.13 5.16 5.19 5.22 5.26** 5.29 5.32 5.35 5.38 5.41 * Nominal pressure
** Rated burst pressureReferences
​​1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Ordering Information. Balloon diameter (mm) ​, Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​.Balloon markers: 2Usable length: 145 cmCoating: HydrophilicLesion entry profile: 0.43 mmStraight-Single Latex Plastic Terumo Accuforce Balloon Catheter, Size: Medium ; Application, Hospital ; Brand, Terumo ; Material, Latex ; Inner Diameter, 36mm. -
Launcher- 8f Guiding Catheter’s
EBU@ (Extra Backup)
LA8EBU30 (EBU 3.0)
LA8EBU35 (EBU 3.5)
LA8EBU375 (EBU 3.75)
LA8EBU40 (EBU 4.0)
LA8EBU45 (EBU 4.5)
LA8EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA8JL30 (JL 3.0)
LA8JL35 (JL 3.5)
LA8JL40 (JL 4.0)
LA8JL45 (JL 4.5)
LA8JL50 (JL 5.0)
LA8JL60 (JL 6.0)
JR@ (Judkin Right )
LA8JR30 (JR 3.0)
LA8JR35 (JR 3.5)
LA8JR40 (JR 4.0)
LA8JR45 (JR 4.5)
LA8JR50 (JR 5.0)
LA8JR60 (JR 6.0)
AL@ (Amplatz Left )
LA8AL75 (AL .75)
LA8AL10 (AL 1.0)
LA8AL15 (AL 1.5)
LA8AL20 (AL 2.0)
LA8AL25 (AL 2.5)
LA8AL30 (AL 3.0)
LA8AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA8SAL75 (SAL . 75)
LA8SAL10 (SAL 1.0)
LA8SAL15 (SAL 1.5)
LA8SAL20 (SAL 2.0)
LA8SAL25 (SAL 2.5)
LA8SAL30 (SAL 3.0)
LA8SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA8AR10 (AR 1.0)
LA8AR20 (AR 2.0)
LA8ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA8ECR35 (ECR 3.5)
LA8ECR40 (ECR 4.0)
LA8ECR45 (ECR 4.5)
LA8RBU35 (RBU 3.5)
LA8RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA8SCR35 (SCR 3.5)
LA8SCR40 (SCR 4.0)
LA8SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA8SAR10 (SAR 1.0)
LA8SAR20 (SAR 2.0)
Multipurpose@
LA8MB1 (MB 1)
LA8MB2 (MB 2)
LA8HSREL (Hockey Stick)
LA8HSI (Hockey I)
LA8HSII (Hockey II)
LA8HSIII (Hockey III)
Bypass Crafts@
LA8LCB (LCB)
LA8RCB (RCB)
LA8RCB (RCB III)
LA8RCB (RCBÂ 90cm)
LA8IMA (IMA)
LA8IMA (IMAÂ 90cm)
-
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILSâ€
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.â€
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.â€
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - â„¢Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Exportâ„¢ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Exportâ„¢ AP aspiration catheter without stylet.
-
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.