TERUMO GLIDE CATHETER cobra2 (C2) 4FR ZB5410GA
TERUMO GLIDE CATHETER Sim2 5FR RF*WA25110M
TERUMO GLIDE CATHETER cobra2 (C2) 5FR RF*ZB5510GM
TERUMO GLIDE CATHETER Sim1 5FR RF*WA15110M
TERUMO GLIDE CATHETER H1 5FR RF*WB15110M
TERUMO GLIDE CATHETER H2 5FR RF*WB25110M
Related products
-
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS
-
PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- ​Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
Shaft diameter 1.9 Fr / 0.64Â mm Proximal
2.5 Fr / 0.84 mm Mid
2.6 Fr / 0.86 mm DistalUsable length 145 cm Balloon markers 2 Nominal pressure 12 atm / 1216 kPa Rated burst pressure 22 atm / 2229 kPa (2.0 mm to 4.0 mm)
20 atm / 2026 kPa (4.5 and 5.0 mm)Guidewire compatibility Maximum diameter 0.014″ / 0.36 mm Lesion entry profile 0.43 mm Coating Hydrophilic Item specifications
Ordering Information
Balloon
diameter
(mm) ​Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​ 6 8 12 15 20 25 30 2.00 DC-RM2006HSW DC-RM2008HSW DC-RM2012HHW DC-RM2015HHW DC-RM2020HHW — — 2.25 DC-RM2206HSW DC-RM2208HSW DC-RM2212HHW DC-RM2215HHW DC-RM2220HHW — — 2.50 DC-RM2506HSW DC-RM2508HSW DC-RM2512HHW DC-RM2515HHW DC-RM2520HHW DC-RM2525HHW DC-RM2530HHW 2.75 DC-RM2706HSW DC-RM2708HSW DC-RM2712HHW DC-RM2715HHW DC-RM2720HHW — — 3.00 DC-RM3006HSW DC-RM3008HSW DC-RM3012HHW DC-RM3015HHW DC-RM3020HHW DC-RM3025HHW DC-RM3030HHW 3.25 DC-RM3206HSW DC-RM3208HSW DC-RM3212HHW DC-RM3215HHW DC-RM3220HHW — — 3.50 DC-RM3506HSW DC-RM3508HSW DC-RM3512HHW DC-RM3515HHW DC-RM3520HHW DC-RM3525HHW DC-RM3530HHW 3.75 DC-RM3706HSW DC-RM3708HSW DC-RM3712HHW DC-RM3715HHW DC-RM3720HHW — — 4.00 DC-RM4006HSW DC-RM4008HSW DC-RM4012HHW DC-RM4015HHW DC-RM4020HHW — — 4.50 DC-RM4506HSW DC-RM4508HSW DC-RM4512HSW DC-RM4515HSW — — — 5.00 DC-RM5006HSW DC-RM5008HSW DC-RM5012HSW DC-RM5015HSW — — — Please quote above item reference codes when placing an order.
Balloon Compliance
Balloon
diameter
(mm) ​Pressure (atm) ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2.00 1.58 1.65 1.72 1.79 1.84 1.88 1.92 1.95 1.98 2.00* 2.01 2.03 2.04 2.05 2.06 2.08 2.09 2.10 2.12 2.13** 2.14 2.15 2.17 2.25 1.96 2.01 2.06 2.11 2.14 2.16 2.19 2.21 2.23 2.25* 2.26 2.28 2.29 2.31 2.32 2.34 2.35 2.36 2.38 2.39** 2.41 2.42 2.44 2.50 2.19 2.24 2.30 2.36 2.38 2.41 2.44 2.46 2.48 2.50* 2.52 2.53 2.55 2.56 2.58 2.60 2.61 2.63 2.64 2.66** 2.68 2.69 2.71 2.75 2.43 2.48 2.53 2.59 2.62 2.65 2.67 2.70 2.73 2.75* 2.77 2.79 2.80 2.82 2.84 2.86 2.87 2.89 2.91 2.93** 2.94 2.96 2.98 3.00 2.65 2.71 2.76 2.82 2.85 2.89 2.92 2.95 2.97 3.00* 3.02 3.04 3.06 3.08 3.10 3.11 3.13 3.15 3.17 3.19** 3.21 3.23 3.25 3.25 2.89 2.95 3.01 3.07 3.10 3.14 3.17 3.20 3.22 3.25* 3.27 3.29 3.31 3.33 3.35 3.37 3.39 3.42 3.44 3.46** 3.47 3.48 3.51 3.50 3.13 3.19 3.26 3.32 3.35 3.39 3.42 3.45 3.47 3.50* 3.52 3.54 3.57 3.59 3.61 3.63 3.65 3.68 3.70 3.72** 3.74 3.74 3.76 3.75 3.37 3.44 3.50 3.56 3.60 3.63 3.66 3.69 3.72 3.75* 3.77 3.80 3.82 3.84 3.86 3.88 3.90 3.92 3.94 3.96** 3.98 3.99 4.01 4.00 3.58 3.65 3.72 3.79 3.83 3.87 3.90 3.94 3.97 4.00* 4.03 4.05 4.07 4.09 4.11 4.13 4.15 4.17 4.19 4.21** 4.23 4.26 4.28 4.50 4.02 4.10 4.19 4.28 4.32 4.37 4.40 4.44 4.47 4.50* 4.53 4.56 4.59 4.63 4.66 4.68 4.71 4.75** 4.78 4.81 4.84 4.87 4.91 5.00 4.52 4.59 4.67 4.75 4.80 4.85 4.89 4.93 4.96 5.00* 5.03 5.07 5.10 5.13 5.16 5.19 5.22 5.26** 5.29 5.32 5.35 5.38 5.41 * Nominal pressure
** Rated burst pressureReferences
​​1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Ordering Information. Balloon diameter (mm) ​, Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​.Balloon markers: 2Usable length: 145 cmCoating: HydrophilicLesion entry profile: 0.43 mmStraight-Single Latex Plastic Terumo Accuforce Balloon Catheter, Size: Medium ; Application, Hospital ; Brand, Terumo ; Material, Latex ; Inner Diameter, 36mm. -
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.ÂOPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitorsÂ








Reviews
There are no reviews yet.