Related products
-
Everest30 INFLATION DEVICE
Everest 30
Disposable Inflation Device
OVERVIEW
Easy-to-use Rapid Inflation/Deflation Device
A simple solution for coronary balloon inflation. The Everest disposable inflation device features a quick trigger release and ergonomic pistol grip for ease of use. Plus, it’s available in your choice of 20 atm or 30 atm pressure gauge, and as a standalone or in a packaged kit.
PRODUCT DETAILS
The Everest Device Features:
- Quick trigger release so you can release pressure immediately, even at higher pressures
- Sure-grip torque knob with a ridged design for “no slip” torque control and precise pressure adjustment
- Unique ergonomic pistol grip with centered trigger that fits comfortably in either hand
- Luminescent dial face that provides accurate readability in normal and low-light conditions
EVEREST DISPOSABLE INFLATION DEVICE ORDERING INFORMATION
Disposable Inflation Device@ AC3200
Survival Kit Inflation Device@ AC305P
Everest20 inflation device
and 3-way stopcockAC2200 1 each Everest30 inflation device
and 3-way stopcockAC3200 1 each Everest20 Survival Kit: - Everest20 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC2205P 1 each Everest30 Survival Kit: - Everest30 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC3205P 1 each ACCESSORIES ORDERING INFORMATION
Metal guidewire insertion tool 006073 5 each Torque handle AC4006 5 each Piton™ Y-Adapter with metal guidewire insertion tool AC4001M 5 each Piton™ Tri-Adapter with metal guidewire insertion tool AC4002M 5 each Piton™ Y-Adapter with metal guidewire insertion tool and torque handle AC4003M 5 each -
Launcher- 5f Guiding Catheter’s
EBU@ (Extra Backup)
LA5EBU30 (EBU 3.0)
LA5EBU35 (EBU 3.5)
LA5EBU375 (EBU 3.75)
LA5EBU40 (EBU 4.0)
LA5EBU45 (EBU 4.5)
LA5EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA5JL30 (JL 3.0)
LA5JL35 (JL 3.5)
LA5JL40 (JL 4.0)
LA5JL45 (JL 4.5)
LA5JL50 (JL 5.0)
LA5JL60 (JL 6.0)
JR@ (Judkin Right )
LA5JR30 (JR 3.0)
LA5JR35 (JR 3.5)
LA5JR40 (JR 4.0)
LA5JR45 (JR 4.5)
LA5JR50 (JR 5.0)
LA5JR60 (JR 6.0)
AL@ (Amplatz Left )
LA5AL75 (AL .75)
LA5AL10 (AL 1.0)
LA5AL15 (AL 1.5)
LA5AL20 (AL 2.0)
LA5AL25 (AL 2.5)
LA5AL30 (AL 3.0)
LA5AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA5SAL75 (SAL . 75)
LA5SAL10 (SAL 1.0)
LA5SAL15 (SAL 1.5)
LA5SAL20 (SAL 2.0)
LA5SAL25 (SAL 2.5)
LA5SAL30 (SAL 3.0)
LA5SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA5AR10 (AR 1.0)
LA5AR20 (AR 2.0)
LA5ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA5ECR35 (ECR 3.5)
LA5ECR40 (ECR 4.0)
LA5ECR45 (ECR 4.5)
LA5RBU35 (RBU 3.5)
LA5RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA5SCR35 (SCR 3.5)
LA5SCR40 (SCR 4.0)
LA5SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA5SAR10 (SAR 1.0)
LA5SAR20 (SAR 2.0)
Multipurpose@
LA5MB1 (MB 1)
LA5MB2 (MB 2)
LA5HSREL (Hockey Stick)
LA5HSI (Hockey I)
LA5HSII (Hockey II)
LA5HSIII (Hockey III)
Bypass Crafts@
LA5LCB (LCB)
LA5RCB (RCB)
LA5RCB (RCB III)
LA5RCB (RCB 90cm)
LA5IMA (IMA)
LA5IMA (IMA 90cm)
-
OCTOPUS TISSUE STABILIZER
Octopus
Tissue Stabilizers
OCTOPUS TISSUE STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS – THE NEXT GENERATION TISSUE STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus™ Evolution – enhanced stability, flexibility, and a lower profile for unlimited positioning options – the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximum stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION – LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizer provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows “toes up” position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 – EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement
-
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.








Reviews
There are no reviews yet.