Spinal Needle
Product Details:
- Spinal needle provides exceptional control when penetrating the dura
- Suitable for spinal anaesthesia
- Aggressive anesthetic distribution upon injection
- High flow rate enables faster Cerebra Spinal Fluid (CSF) flashback
- Clear polycarbonate hub offers easy visualization of CSF or blood
- Conical tip imparts superior tactile feedback
- Sterile product for single use
Related products
-
RADIFOCUS REDIAL SHEATH
Providing you the best range of Terumo Radifocus Radial Introducer Sheath and Cordis Femoral Introducer Sheath with effective & timely delivery.
The radial artery access sheath is used to gain arterial access and facilitate the insertion of catheters or other equipment for diagnostic and vascular interventions.
- The Cordis AVANTI®+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI®+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates procedural flexibility. It stays in place and allows patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and helps to minimize damage upon entry.
As part of the circulatory system, the radial artery supplies blood from the heart to the forearm.
Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.
-
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphoraâ„¢ noncompliant balloon
NC Euphora™ noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora™ noncompliant balloon dilatation catheter has what you’re looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it — so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X  NCEUP32508X  NCEUP32512X 3.50 NCEUP3506X  NCEUP3508X  NCEUP3512X 3.75 NCEUP37506X  NCEUP37508X  NCEUP37512X 4.00 NCEUP4006X  NCEUP4008X  NCEUP4012X 4.50  —  NCEUP4508X  NCEUP4512X 5.00  —  NCEUP5008X  NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X — 2.25 NCEUP22515X NCEUP22520X — 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25  NCEUP32515X  NCEUP32520X  NCEUP32527X 3.50  NCEUP3515X  NCEUP3520X  NCEUP3527X 3.75  NCEUP37515X  NCEUP37520X  NCEUP37527X 4.00  NCEUP4015X  NCEUP4020X  NCEUP4027X 4.50  NCEUP4515X  NCEUP4520X  — 5.00  NCEUP5015X —  — -
ACT CARTRIDGE (HR-ACT)
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
SKU:402-03Weight:3.00 LBSAvailability:2-3 Business daysShipping:Calculated at checkoutQuantity:Product Description
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50Â
                   ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box 402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box 402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box 402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box -
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinterâ„¢ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinterâ„¢ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Â Selective Dura-Trac coating
- Â 2.5 mm tip
- Â FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip









Quiernera –
Dro4er kHAHeqtRZHdUl 6 17 2022 priligy in usa
Quiernera –
[url=https://fastpriligy.top/]priligy 60 mg price[/url] 2010; 37 258 81