RUNTHROUGH® NS EXTRA FLOPPY(PTCA WIRE)
PRODUCT OVERVIEW
Designed to be your first choice coronary guidewire
The RUNTHROUGH NS Extra Floppy is designed to be an all-in-one workhorse wire with a soft, atraumatic, low tip weight wire that can be used to access most everyday and complex lesions.
NITINOL CORE-TO-TIP DESIGN FOR EXCELLENT TIP DURABILITY
This feature enables a single RUNTHROUGH wire to be used for multiple vessels potentially reducing a facility’s wire usage, saving both time and money.1
DIRECT
JOINT-DUO CORETM TECHNOLOGY
Innovative technology enables connection of two different metal characteristics. This seamless fusion of two proven guidewire metals provides 1:1 torque response/steerability, pushability and trackability.1
BALANCE OF HYDROPHILIC AND HYDROPHOBIC
COATING
“M-coat” technology hydrophilic coating over the distal 24.8cm of the distal tip enables smooth trackability in the tortuous anatomy while the silicone tip on the distal 2mm provides tactile feedback and system support for device delivery.1
PRODUCT CODES
RUNTHROUGH NS Extra Floppy
| Product Code | Diameter | Length | Tip Radiopacity | Tip Shape |
| 25-1011 | 0.014″ | 180cm | 3cm | Straight |
| 25-1013 | 0.014″ | 300cm | 3cm | Straight |
| 25-9092 | 0.014″ | 150cm | N/A | N/A |
The RUNTHROUGH NS Extra Floppy is designed to be an all-in-one workhorse wire with a soft, atraumatic, low tip weight wire that can be used to access most everyday and complex lesions.
GUIDE WIRES are intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA).
Superb seamless joint technology. The direct-joint Runthrough NS series deliver definitive torque response and easier, more flexible steering control.
RUNTHROUGH® NS EXTRA FLOPPY(PTCA WIRE)
Related products
-
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinter™ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinter™ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Selective Dura-Trac coating
- 2.5 mm tip
- FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip
-
RADIFOCUS INTRODUCER SHEATH
Radifocus™ Introducer II Standard Kit A
Introducer Sheath (FEMORAL)
Kit of vascular introducer with hemostatic valve with excellent blood tightness,
easy and non traumatic vessel insertion, patented valve design for a unique
features package.- Total Integrated Fit (TIF) tip tapering: tapering design at the tip of the sheath and dilator to facilitate smooth penetration
- Cross-cut hemostasis valve to avoid blood reflux and air aspiration
- Thin radiopaque sheath with anti-kinking sleeve for easy catheter handling
- Snap-on/click-off dilator lock prevents dilator back-out during insertion and allows one-hand unlocking
- Wide variety of kit variations providing all elements for quick vessel access: 4-11 Fr sheaths, 5-16 cm lengths, Surf lash needle
General specifications
Sheath length 10 cm Mini guidewire Plastic Straight and Angled
0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type; 0.035″ (0.89 mm) for all others
45 cmEntry needle Plastic IV Catheter – 18G x 2 ½” (1.2 x 64 mm),
except for 4 Fr with 45 cm straight mini guidewire: 20G x 2″ (0.9 x 51 mm)
2.5 ml syringe is includedGuidewire compatibility 0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type
0.035″ (0.89 mm) for all othersPackaging Tray A Kit content Sheath, dilator, plastic mini guidewire and plastic IV catheter (entry needle) Item specifications
Inner diameter Mini guidewire type 45 cm angled 45 cm straight 4 Fr RS+A40K10AQ RS+A40G10SQ 4 Fr RS*A40G10SQ RS*A40G05SQ 4 Fr RS*A40K10SQ RS*A40G07SQ 5 Fr RS*A50K10AQ RS*A50G07SQ 5 Fr RS+A50K10AQ RS+A50K10SQ 6 Fr RS+A60K10AQ RS+A60K10SQ 6 Fr RS*A60K10AQ RS*A60G07SQ 6 Fr — RS*A60G16SQZ 6 Fr — RS*A60K10SQ 6 Fr — RS+A50K10SQ 7 Fr — RS+A70K10SQ 7 Fr — RS*A70G07SQ 7 Fr — RS*A70K10SQ 8 Fr — RS+A80K10SQ 8 Fr — RS*A80K10SQ 9 Fr — RS*A90K10SQ 10 Fr — RS*A10K10SQ 11 Fr — RS*A11K10SQ A Kit includes: introducer sheath, dilator, mini Guide wire, entry venous catheter, 2.5 cc syringe
B Kit includes: introducer sheath, dilator, mini Guide wire
C Kit includes: introducer sheath, dilator
R Kit includes: introducer sheath, dilator, mini Guide wire, 18 G x 2 3/4” / 1.2 x 70 mm entry metallic needle
Other code numbers are available on special demand. For any further information, please contact your Terumo local representative
Units per box: 5 for kits in tray and 10 for kits in pouch. -
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.
-
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technology where the outside diameter is reduced by one French size while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumo’s proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumo’s proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Association’s identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGY™: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.









Reviews