PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- ​Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
| Shaft diameter | 1.9 Fr / 0.64Â mm Proximal 2.5 Fr / 0.84 mm Mid 2.6 Fr / 0.86 mm Distal |
|---|---|
| Usable length | 145 cm |
| Balloon markers | 2 |
| Nominal pressure | 12 atm / 1216 kPa |
| Rated burst pressure | 22 atm / 2229 kPa (2.0 mm to 4.0 mm) 20 atm / 2026 kPa (4.5 and 5.0 mm) |
| Guidewire compatibility | Maximum diameter 0.014″ / 0.36 mm |
| Lesion entry profile | 0.43 mm |
| Coating | Hydrophilic |
Item specifications
Ordering Information
| Balloon diameter (mm) ​ |
Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​ | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | 30 | |
| 2.00 | DC-RM2006HSW | DC-RM2008HSW | DC-RM2012HHW | DC-RM2015HHW | DC-RM2020HHW | — | — |
| 2.25 | DC-RM2206HSW | DC-RM2208HSW | DC-RM2212HHW | DC-RM2215HHW | DC-RM2220HHW | — | — |
| 2.50 | DC-RM2506HSW | DC-RM2508HSW | DC-RM2512HHW | DC-RM2515HHW | DC-RM2520HHW | DC-RM2525HHW | DC-RM2530HHW |
| 2.75 | DC-RM2706HSW | DC-RM2708HSW | DC-RM2712HHW | DC-RM2715HHW | DC-RM2720HHW | — | — |
| 3.00 | DC-RM3006HSW | DC-RM3008HSW | DC-RM3012HHW | DC-RM3015HHW | DC-RM3020HHW | DC-RM3025HHW | DC-RM3030HHW |
| 3.25 | DC-RM3206HSW | DC-RM3208HSW | DC-RM3212HHW | DC-RM3215HHW | DC-RM3220HHW | — | — |
| 3.50 | DC-RM3506HSW | DC-RM3508HSW | DC-RM3512HHW | DC-RM3515HHW | DC-RM3520HHW | DC-RM3525HHW | DC-RM3530HHW |
| 3.75 | DC-RM3706HSW | DC-RM3708HSW | DC-RM3712HHW | DC-RM3715HHW | DC-RM3720HHW | — | — |
| 4.00 | DC-RM4006HSW | DC-RM4008HSW | DC-RM4012HHW | DC-RM4015HHW | DC-RM4020HHW | — | — |
| 4.50 | DC-RM4506HSW | DC-RM4508HSW | DC-RM4512HSW | DC-RM4515HSW | — | — | — |
| 5.00 | DC-RM5006HSW | DC-RM5008HSW | DC-RM5012HSW | DC-RM5015HSW | — | — | — |
Please quote above item reference codes when placing an order.
Balloon Compliance
| Balloon diameter (mm) ​ |
Pressure (atm) ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | |
| 2.00 | 1.58 | 1.65 | 1.72 | 1.79 | 1.84 | 1.88 | 1.92 | 1.95 | 1.98 | 2.00* | 2.01 | 2.03 | 2.04 | 2.05 | 2.06 | 2.08 | 2.09 | 2.10 | 2.12 | 2.13** | 2.14 | 2.15 | 2.17 |
| 2.25 | 1.96 | 2.01 | 2.06 | 2.11 | 2.14 | 2.16 | 2.19 | 2.21 | 2.23 | 2.25* | 2.26 | 2.28 | 2.29 | 2.31 | 2.32 | 2.34 | 2.35 | 2.36 | 2.38 | 2.39** | 2.41 | 2.42 | 2.44 |
| 2.50 | 2.19 | 2.24 | 2.30 | 2.36 | 2.38 | 2.41 | 2.44 | 2.46 | 2.48 | 2.50* | 2.52 | 2.53 | 2.55 | 2.56 | 2.58 | 2.60 | 2.61 | 2.63 | 2.64 | 2.66** | 2.68 | 2.69 | 2.71 |
| 2.75 | 2.43 | 2.48 | 2.53 | 2.59 | 2.62 | 2.65 | 2.67 | 2.70 | 2.73 | 2.75* | 2.77 | 2.79 | 2.80 | 2.82 | 2.84 | 2.86 | 2.87 | 2.89 | 2.91 | 2.93** | 2.94 | 2.96 | 2.98 |
| 3.00 | 2.65 | 2.71 | 2.76 | 2.82 | 2.85 | 2.89 | 2.92 | 2.95 | 2.97 | 3.00* | 3.02 | 3.04 | 3.06 | 3.08 | 3.10 | 3.11 | 3.13 | 3.15 | 3.17 | 3.19** | 3.21 | 3.23 | 3.25 |
| 3.25 | 2.89 | 2.95 | 3.01 | 3.07 | 3.10 | 3.14 | 3.17 | 3.20 | 3.22 | 3.25* | 3.27 | 3.29 | 3.31 | 3.33 | 3.35 | 3.37 | 3.39 | 3.42 | 3.44 | 3.46** | 3.47 | 3.48 | 3.51 |
| 3.50 | 3.13 | 3.19 | 3.26 | 3.32 | 3.35 | 3.39 | 3.42 | 3.45 | 3.47 | 3.50* | 3.52 | 3.54 | 3.57 | 3.59 | 3.61 | 3.63 | 3.65 | 3.68 | 3.70 | 3.72** | 3.74 | 3.74 | 3.76 |
| 3.75 | 3.37 | 3.44 | 3.50 | 3.56 | 3.60 | 3.63 | 3.66 | 3.69 | 3.72 | 3.75* | 3.77 | 3.80 | 3.82 | 3.84 | 3.86 | 3.88 | 3.90 | 3.92 | 3.94 | 3.96** | 3.98 | 3.99 | 4.01 |
| 4.00 | 3.58 | 3.65 | 3.72 | 3.79 | 3.83 | 3.87 | 3.90 | 3.94 | 3.97 | 4.00* | 4.03 | 4.05 | 4.07 | 4.09 | 4.11 | 4.13 | 4.15 | 4.17 | 4.19 | 4.21** | 4.23 | 4.26 | 4.28 |
| 4.50 | 4.02 | 4.10 | 4.19 | 4.28 | 4.32 | 4.37 | 4.40 | 4.44 | 4.47 | 4.50* | 4.53 | 4.56 | 4.59 | 4.63 | 4.66 | 4.68 | 4.71 | 4.75** | 4.78 | 4.81 | 4.84 | 4.87 | 4.91 |
| 5.00 | 4.52 | 4.59 | 4.67 | 4.75 | 4.80 | 4.85 | 4.89 | 4.93 | 4.96 | 5.00* | 5.03 | 5.07 | 5.10 | 5.13 | 5.16 | 5.19 | 5.22 | 5.26** | 5.29 | 5.32 | 5.35 | 5.38 | 5.41 |
** Rated burst pressure
References
​​1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Related products
-
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technology where the outside diameter is reduced by one French size while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumo’s proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumo’s proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Association’s identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGYâ„¢: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.
-
Launcher- 8f Guiding Catheter’s
EBU@ (Extra Backup)
LA8EBU30 (EBU 3.0)
LA8EBU35 (EBU 3.5)
LA8EBU375 (EBU 3.75)
LA8EBU40 (EBU 4.0)
LA8EBU45 (EBU 4.5)
LA8EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA8JL30 (JL 3.0)
LA8JL35 (JL 3.5)
LA8JL40 (JL 4.0)
LA8JL45 (JL 4.5)
LA8JL50 (JL 5.0)
LA8JL60 (JL 6.0)
JR@ (Judkin Right )
LA8JR30 (JR 3.0)
LA8JR35 (JR 3.5)
LA8JR40 (JR 4.0)
LA8JR45 (JR 4.5)
LA8JR50 (JR 5.0)
LA8JR60 (JR 6.0)
AL@ (Amplatz Left )
LA8AL75 (AL .75)
LA8AL10 (AL 1.0)
LA8AL15 (AL 1.5)
LA8AL20 (AL 2.0)
LA8AL25 (AL 2.5)
LA8AL30 (AL 3.0)
LA8AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA8SAL75 (SAL . 75)
LA8SAL10 (SAL 1.0)
LA8SAL15 (SAL 1.5)
LA8SAL20 (SAL 2.0)
LA8SAL25 (SAL 2.5)
LA8SAL30 (SAL 3.0)
LA8SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA8AR10 (AR 1.0)
LA8AR20 (AR 2.0)
LA8ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA8ECR35 (ECR 3.5)
LA8ECR40 (ECR 4.0)
LA8ECR45 (ECR 4.5)
LA8RBU35 (RBU 3.5)
LA8RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA8SCR35 (SCR 3.5)
LA8SCR40 (SCR 4.0)
LA8SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA8SAR10 (SAR 1.0)
LA8SAR20 (SAR 2.0)
Multipurpose@
LA8MB1 (MB 1)
LA8MB2 (MB 2)
LA8HSREL (Hockey Stick)
LA8HSI (Hockey I)
LA8HSII (Hockey II)
LA8HSIII (Hockey III)
Bypass Crafts@
LA8LCB (LCB)
LA8RCB (RCB)
LA8RCB (RCB III)
LA8RCB (RCBÂ 90cm)
LA8IMA (IMA)
LA8IMA (IMAÂ 90cm)
-
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinterâ„¢ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinterâ„¢ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Â Selective Dura-Trac coating
- Â 2.5 mm tip
- Â FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.ÂOPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitorsÂ









Reviews