PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
| Shaft diameter | 1.9 Fr / 0.64 mm Proximal 2.5 Fr / 0.84 mm Mid 2.6 Fr / 0.86 mm Distal |
|---|---|
| Usable length | 145 cm |
| Balloon markers | 2 |
| Nominal pressure | 12 atm / 1216 kPa |
| Rated burst pressure | 22 atm / 2229 kPa (2.0 mm to 4.0 mm) 20 atm / 2026 kPa (4.5 and 5.0 mm) |
| Guidewire compatibility | Maximum diameter 0.014″ / 0.36 mm |
| Lesion entry profile | 0.43 mm |
| Coating | Hydrophilic |
Item specifications
Ordering Information
| Balloon diameter (mm) |
Balloon length (mm) / Item references | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | 30 | |
| 2.00 | DC-RM2006HSW | DC-RM2008HSW | DC-RM2012HHW | DC-RM2015HHW | DC-RM2020HHW | — | — |
| 2.25 | DC-RM2206HSW | DC-RM2208HSW | DC-RM2212HHW | DC-RM2215HHW | DC-RM2220HHW | — | — |
| 2.50 | DC-RM2506HSW | DC-RM2508HSW | DC-RM2512HHW | DC-RM2515HHW | DC-RM2520HHW | DC-RM2525HHW | DC-RM2530HHW |
| 2.75 | DC-RM2706HSW | DC-RM2708HSW | DC-RM2712HHW | DC-RM2715HHW | DC-RM2720HHW | — | — |
| 3.00 | DC-RM3006HSW | DC-RM3008HSW | DC-RM3012HHW | DC-RM3015HHW | DC-RM3020HHW | DC-RM3025HHW | DC-RM3030HHW |
| 3.25 | DC-RM3206HSW | DC-RM3208HSW | DC-RM3212HHW | DC-RM3215HHW | DC-RM3220HHW | — | — |
| 3.50 | DC-RM3506HSW | DC-RM3508HSW | DC-RM3512HHW | DC-RM3515HHW | DC-RM3520HHW | DC-RM3525HHW | DC-RM3530HHW |
| 3.75 | DC-RM3706HSW | DC-RM3708HSW | DC-RM3712HHW | DC-RM3715HHW | DC-RM3720HHW | — | — |
| 4.00 | DC-RM4006HSW | DC-RM4008HSW | DC-RM4012HHW | DC-RM4015HHW | DC-RM4020HHW | — | — |
| 4.50 | DC-RM4506HSW | DC-RM4508HSW | DC-RM4512HSW | DC-RM4515HSW | — | — | — |
| 5.00 | DC-RM5006HSW | DC-RM5008HSW | DC-RM5012HSW | DC-RM5015HSW | — | — | — |
Please quote above item reference codes when placing an order.
Balloon Compliance
| Balloon diameter (mm) |
Pressure (atm) | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | |
| 2.00 | 1.58 | 1.65 | 1.72 | 1.79 | 1.84 | 1.88 | 1.92 | 1.95 | 1.98 | 2.00* | 2.01 | 2.03 | 2.04 | 2.05 | 2.06 | 2.08 | 2.09 | 2.10 | 2.12 | 2.13** | 2.14 | 2.15 | 2.17 |
| 2.25 | 1.96 | 2.01 | 2.06 | 2.11 | 2.14 | 2.16 | 2.19 | 2.21 | 2.23 | 2.25* | 2.26 | 2.28 | 2.29 | 2.31 | 2.32 | 2.34 | 2.35 | 2.36 | 2.38 | 2.39** | 2.41 | 2.42 | 2.44 |
| 2.50 | 2.19 | 2.24 | 2.30 | 2.36 | 2.38 | 2.41 | 2.44 | 2.46 | 2.48 | 2.50* | 2.52 | 2.53 | 2.55 | 2.56 | 2.58 | 2.60 | 2.61 | 2.63 | 2.64 | 2.66** | 2.68 | 2.69 | 2.71 |
| 2.75 | 2.43 | 2.48 | 2.53 | 2.59 | 2.62 | 2.65 | 2.67 | 2.70 | 2.73 | 2.75* | 2.77 | 2.79 | 2.80 | 2.82 | 2.84 | 2.86 | 2.87 | 2.89 | 2.91 | 2.93** | 2.94 | 2.96 | 2.98 |
| 3.00 | 2.65 | 2.71 | 2.76 | 2.82 | 2.85 | 2.89 | 2.92 | 2.95 | 2.97 | 3.00* | 3.02 | 3.04 | 3.06 | 3.08 | 3.10 | 3.11 | 3.13 | 3.15 | 3.17 | 3.19** | 3.21 | 3.23 | 3.25 |
| 3.25 | 2.89 | 2.95 | 3.01 | 3.07 | 3.10 | 3.14 | 3.17 | 3.20 | 3.22 | 3.25* | 3.27 | 3.29 | 3.31 | 3.33 | 3.35 | 3.37 | 3.39 | 3.42 | 3.44 | 3.46** | 3.47 | 3.48 | 3.51 |
| 3.50 | 3.13 | 3.19 | 3.26 | 3.32 | 3.35 | 3.39 | 3.42 | 3.45 | 3.47 | 3.50* | 3.52 | 3.54 | 3.57 | 3.59 | 3.61 | 3.63 | 3.65 | 3.68 | 3.70 | 3.72** | 3.74 | 3.74 | 3.76 |
| 3.75 | 3.37 | 3.44 | 3.50 | 3.56 | 3.60 | 3.63 | 3.66 | 3.69 | 3.72 | 3.75* | 3.77 | 3.80 | 3.82 | 3.84 | 3.86 | 3.88 | 3.90 | 3.92 | 3.94 | 3.96** | 3.98 | 3.99 | 4.01 |
| 4.00 | 3.58 | 3.65 | 3.72 | 3.79 | 3.83 | 3.87 | 3.90 | 3.94 | 3.97 | 4.00* | 4.03 | 4.05 | 4.07 | 4.09 | 4.11 | 4.13 | 4.15 | 4.17 | 4.19 | 4.21** | 4.23 | 4.26 | 4.28 |
| 4.50 | 4.02 | 4.10 | 4.19 | 4.28 | 4.32 | 4.37 | 4.40 | 4.44 | 4.47 | 4.50* | 4.53 | 4.56 | 4.59 | 4.63 | 4.66 | 4.68 | 4.71 | 4.75** | 4.78 | 4.81 | 4.84 | 4.87 | 4.91 |
| 5.00 | 4.52 | 4.59 | 4.67 | 4.75 | 4.80 | 4.85 | 4.89 | 4.93 | 4.96 | 5.00* | 5.03 | 5.07 | 5.10 | 5.13 | 5.16 | 5.19 | 5.22 | 5.26** | 5.29 | 5.32 | 5.35 | 5.38 | 5.41 |
** Rated burst pressure
References
1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Related products
-
Launcher- 6f Guiding Catheter’s
EBU@ (Extra Backup)
LA6EBU30 (EBU 3.0)
LA6EBU35 (EBU 3.5)
LA6EBU375 (EBU 3.75)
LA6EBU40 (EBU 4.0)
LA6EBU45 (EBU 4.5)
LA6EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA6JL30 (JL 3.0)
LA6JL35 (JL 3.5)
LA6JL40 (JL 4.0)
LA6JL45 (JL 4.5)
LA6JL50 (JL 5.0)
LA6JL60 (JL 6.0)
JR@ (Judkin Right )
LA6JR30 (JR 3.0)
LA6JR35 (JR 3.5)
LA6JR40 (JR 4.0)
LA6JR45 (JR 4.5)
LA6JR50 (JR 5.0)
LA6JR60 (JR 6.0)
AL@ (Amplatz Left )
LA6AL75 (AL .75)
LA6AL10 (AL 1.0)
LA6AL15 (AL 1.5)
LA6AL20 (AL 2.0)
LA6AL25 (AL 2.5)
LA6AL30 (AL 3.0)
LA6AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA6SAL75 (SAL . 75)
LA6SAL10 (SAL 1.0)
LA6SAL15 (SAL 1.5)
LA6SAL20 (SAL 2.0)
LA6SAL25 (SAL 2.5)
LA6SAL30 (SAL 3.0)
LA6SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA6AR10 (AR 1.0)
LA6AR20 (AR 2.0)
LA6ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA6ECR35 (ECR 3.5)
LA6ECR40 (ECR 4.0)
LA6ECR45 (ECR 4.5)
LA6RBU35 (RBU 3.5)
LA6RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA6SCR35 (SCR 3.5)
LA6SCR40 (SCR 4.0)
LA6SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA6SAR10 (SAR 1.0)
LA6SAR20 (SAR 2.0)
Multipurpose@
LA6MB1 (MB 1)
LA6MB2 (MB 2)
LA6HSREL (Hockey Stick)
LA6HSI (Hockey I)
LA6HSII (Hockey II)
LA6HSIII (Hockey III)
Bypass Crafts@
LA6LCB (LCB)
LA6RCB (RCB)
LA6RCB (RCB III)
LA6RCB (RCB 90cm)
LA6IMA (IMA)
LA6IMA (IMA 90cm)
-
OCTOPUS TISSUE STABILIZER
Octopus
Tissue Stabilizers
OCTOPUS TISSUE STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS – THE NEXT GENERATION TISSUE STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus™ Evolution – enhanced stability, flexibility, and a lower profile for unlimited positioning options – the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximum stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION – LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizer provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows “toes up” position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 – EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement
-
ACT CARTRIDGE (HR-ACT)
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
SKU:402-03Weight:3.00 LBSAvailability:2-3 Business daysShipping:Calculated at checkoutQuantity:Product Description
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box 402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box 402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box 402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box -
Launcher- 5f Guiding Catheter’s
EBU@ (Extra Backup)
LA5EBU30 (EBU 3.0)
LA5EBU35 (EBU 3.5)
LA5EBU375 (EBU 3.75)
LA5EBU40 (EBU 4.0)
LA5EBU45 (EBU 4.5)
LA5EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA5JL30 (JL 3.0)
LA5JL35 (JL 3.5)
LA5JL40 (JL 4.0)
LA5JL45 (JL 4.5)
LA5JL50 (JL 5.0)
LA5JL60 (JL 6.0)
JR@ (Judkin Right )
LA5JR30 (JR 3.0)
LA5JR35 (JR 3.5)
LA5JR40 (JR 4.0)
LA5JR45 (JR 4.5)
LA5JR50 (JR 5.0)
LA5JR60 (JR 6.0)
AL@ (Amplatz Left )
LA5AL75 (AL .75)
LA5AL10 (AL 1.0)
LA5AL15 (AL 1.5)
LA5AL20 (AL 2.0)
LA5AL25 (AL 2.5)
LA5AL30 (AL 3.0)
LA5AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA5SAL75 (SAL . 75)
LA5SAL10 (SAL 1.0)
LA5SAL15 (SAL 1.5)
LA5SAL20 (SAL 2.0)
LA5SAL25 (SAL 2.5)
LA5SAL30 (SAL 3.0)
LA5SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA5AR10 (AR 1.0)
LA5AR20 (AR 2.0)
LA5ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA5ECR35 (ECR 3.5)
LA5ECR40 (ECR 4.0)
LA5ECR45 (ECR 4.5)
LA5RBU35 (RBU 3.5)
LA5RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA5SCR35 (SCR 3.5)
LA5SCR40 (SCR 4.0)
LA5SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA5SAR10 (SAR 1.0)
LA5SAR20 (SAR 2.0)
Multipurpose@
LA5MB1 (MB 1)
LA5MB2 (MB 2)
LA5HSREL (Hockey Stick)
LA5HSI (Hockey I)
LA5HSII (Hockey II)
LA5HSIII (Hockey III)
Bypass Crafts@
LA5LCB (LCB)
LA5RCB (RCB)
LA5RCB (RCB III)
LA5RCB (RCB 90cm)
LA5IMA (IMA)
LA5IMA (IMA 90cm)









Reviews
There are no reviews yet.