PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- ​Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
| Shaft diameter | 1.9 Fr / 0.64Â mm Proximal 2.5 Fr / 0.84 mm Mid 2.6 Fr / 0.86 mm Distal |
|---|---|
| Usable length | 145 cm |
| Balloon markers | 2 |
| Nominal pressure | 12 atm / 1216 kPa |
| Rated burst pressure | 22 atm / 2229 kPa (2.0 mm to 4.0 mm) 20 atm / 2026 kPa (4.5 and 5.0 mm) |
| Guidewire compatibility | Maximum diameter 0.014″ / 0.36 mm |
| Lesion entry profile | 0.43 mm |
| Coating | Hydrophilic |
Item specifications
Ordering Information
| Balloon diameter (mm) ​ |
Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​ | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | 30 | |
| 2.00 | DC-RM2006HSW | DC-RM2008HSW | DC-RM2012HHW | DC-RM2015HHW | DC-RM2020HHW | — | — |
| 2.25 | DC-RM2206HSW | DC-RM2208HSW | DC-RM2212HHW | DC-RM2215HHW | DC-RM2220HHW | — | — |
| 2.50 | DC-RM2506HSW | DC-RM2508HSW | DC-RM2512HHW | DC-RM2515HHW | DC-RM2520HHW | DC-RM2525HHW | DC-RM2530HHW |
| 2.75 | DC-RM2706HSW | DC-RM2708HSW | DC-RM2712HHW | DC-RM2715HHW | DC-RM2720HHW | — | — |
| 3.00 | DC-RM3006HSW | DC-RM3008HSW | DC-RM3012HHW | DC-RM3015HHW | DC-RM3020HHW | DC-RM3025HHW | DC-RM3030HHW |
| 3.25 | DC-RM3206HSW | DC-RM3208HSW | DC-RM3212HHW | DC-RM3215HHW | DC-RM3220HHW | — | — |
| 3.50 | DC-RM3506HSW | DC-RM3508HSW | DC-RM3512HHW | DC-RM3515HHW | DC-RM3520HHW | DC-RM3525HHW | DC-RM3530HHW |
| 3.75 | DC-RM3706HSW | DC-RM3708HSW | DC-RM3712HHW | DC-RM3715HHW | DC-RM3720HHW | — | — |
| 4.00 | DC-RM4006HSW | DC-RM4008HSW | DC-RM4012HHW | DC-RM4015HHW | DC-RM4020HHW | — | — |
| 4.50 | DC-RM4506HSW | DC-RM4508HSW | DC-RM4512HSW | DC-RM4515HSW | — | — | — |
| 5.00 | DC-RM5006HSW | DC-RM5008HSW | DC-RM5012HSW | DC-RM5015HSW | — | — | — |
Please quote above item reference codes when placing an order.
Balloon Compliance
| Balloon diameter (mm) ​ |
Pressure (atm) ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | |
| 2.00 | 1.58 | 1.65 | 1.72 | 1.79 | 1.84 | 1.88 | 1.92 | 1.95 | 1.98 | 2.00* | 2.01 | 2.03 | 2.04 | 2.05 | 2.06 | 2.08 | 2.09 | 2.10 | 2.12 | 2.13** | 2.14 | 2.15 | 2.17 |
| 2.25 | 1.96 | 2.01 | 2.06 | 2.11 | 2.14 | 2.16 | 2.19 | 2.21 | 2.23 | 2.25* | 2.26 | 2.28 | 2.29 | 2.31 | 2.32 | 2.34 | 2.35 | 2.36 | 2.38 | 2.39** | 2.41 | 2.42 | 2.44 |
| 2.50 | 2.19 | 2.24 | 2.30 | 2.36 | 2.38 | 2.41 | 2.44 | 2.46 | 2.48 | 2.50* | 2.52 | 2.53 | 2.55 | 2.56 | 2.58 | 2.60 | 2.61 | 2.63 | 2.64 | 2.66** | 2.68 | 2.69 | 2.71 |
| 2.75 | 2.43 | 2.48 | 2.53 | 2.59 | 2.62 | 2.65 | 2.67 | 2.70 | 2.73 | 2.75* | 2.77 | 2.79 | 2.80 | 2.82 | 2.84 | 2.86 | 2.87 | 2.89 | 2.91 | 2.93** | 2.94 | 2.96 | 2.98 |
| 3.00 | 2.65 | 2.71 | 2.76 | 2.82 | 2.85 | 2.89 | 2.92 | 2.95 | 2.97 | 3.00* | 3.02 | 3.04 | 3.06 | 3.08 | 3.10 | 3.11 | 3.13 | 3.15 | 3.17 | 3.19** | 3.21 | 3.23 | 3.25 |
| 3.25 | 2.89 | 2.95 | 3.01 | 3.07 | 3.10 | 3.14 | 3.17 | 3.20 | 3.22 | 3.25* | 3.27 | 3.29 | 3.31 | 3.33 | 3.35 | 3.37 | 3.39 | 3.42 | 3.44 | 3.46** | 3.47 | 3.48 | 3.51 |
| 3.50 | 3.13 | 3.19 | 3.26 | 3.32 | 3.35 | 3.39 | 3.42 | 3.45 | 3.47 | 3.50* | 3.52 | 3.54 | 3.57 | 3.59 | 3.61 | 3.63 | 3.65 | 3.68 | 3.70 | 3.72** | 3.74 | 3.74 | 3.76 |
| 3.75 | 3.37 | 3.44 | 3.50 | 3.56 | 3.60 | 3.63 | 3.66 | 3.69 | 3.72 | 3.75* | 3.77 | 3.80 | 3.82 | 3.84 | 3.86 | 3.88 | 3.90 | 3.92 | 3.94 | 3.96** | 3.98 | 3.99 | 4.01 |
| 4.00 | 3.58 | 3.65 | 3.72 | 3.79 | 3.83 | 3.87 | 3.90 | 3.94 | 3.97 | 4.00* | 4.03 | 4.05 | 4.07 | 4.09 | 4.11 | 4.13 | 4.15 | 4.17 | 4.19 | 4.21** | 4.23 | 4.26 | 4.28 |
| 4.50 | 4.02 | 4.10 | 4.19 | 4.28 | 4.32 | 4.37 | 4.40 | 4.44 | 4.47 | 4.50* | 4.53 | 4.56 | 4.59 | 4.63 | 4.66 | 4.68 | 4.71 | 4.75** | 4.78 | 4.81 | 4.84 | 4.87 | 4.91 |
| 5.00 | 4.52 | 4.59 | 4.67 | 4.75 | 4.80 | 4.85 | 4.89 | 4.93 | 4.96 | 5.00* | 5.03 | 5.07 | 5.10 | 5.13 | 5.16 | 5.19 | 5.22 | 5.26** | 5.29 | 5.32 | 5.35 | 5.38 | 5.41 |
** Rated burst pressure
References
​​1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Related products
-
Launcher- 8f Guiding Catheter’s
EBU@ (Extra Backup)
LA8EBU30 (EBU 3.0)
LA8EBU35 (EBU 3.5)
LA8EBU375 (EBU 3.75)
LA8EBU40 (EBU 4.0)
LA8EBU45 (EBU 4.5)
LA8EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA8JL30 (JL 3.0)
LA8JL35 (JL 3.5)
LA8JL40 (JL 4.0)
LA8JL45 (JL 4.5)
LA8JL50 (JL 5.0)
LA8JL60 (JL 6.0)
JR@ (Judkin Right )
LA8JR30 (JR 3.0)
LA8JR35 (JR 3.5)
LA8JR40 (JR 4.0)
LA8JR45 (JR 4.5)
LA8JR50 (JR 5.0)
LA8JR60 (JR 6.0)
AL@ (Amplatz Left )
LA8AL75 (AL .75)
LA8AL10 (AL 1.0)
LA8AL15 (AL 1.5)
LA8AL20 (AL 2.0)
LA8AL25 (AL 2.5)
LA8AL30 (AL 3.0)
LA8AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA8SAL75 (SAL . 75)
LA8SAL10 (SAL 1.0)
LA8SAL15 (SAL 1.5)
LA8SAL20 (SAL 2.0)
LA8SAL25 (SAL 2.5)
LA8SAL30 (SAL 3.0)
LA8SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA8AR10 (AR 1.0)
LA8AR20 (AR 2.0)
LA8ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA8ECR35 (ECR 3.5)
LA8ECR40 (ECR 4.0)
LA8ECR45 (ECR 4.5)
LA8RBU35 (RBU 3.5)
LA8RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA8SCR35 (SCR 3.5)
LA8SCR40 (SCR 4.0)
LA8SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA8SAR10 (SAR 1.0)
LA8SAR20 (SAR 2.0)
Multipurpose@
LA8MB1 (MB 1)
LA8MB2 (MB 2)
LA8HSREL (Hockey Stick)
LA8HSI (Hockey I)
LA8HSII (Hockey II)
LA8HSIII (Hockey III)
Bypass Crafts@
LA8LCB (LCB)
LA8RCB (RCB)
LA8RCB (RCB III)
LA8RCB (RCBÂ 90cm)
LA8IMA (IMA)
LA8IMA (IMAÂ 90cm)
-
Launcher- 6f Guiding Catheter’s
EBU@ (Extra Backup)
LA6EBU30 (EBU 3.0)
LA6EBU35 (EBU 3.5)
LA6EBU375 (EBU 3.75)
LA6EBU40 (EBU 4.0)
LA6EBU45 (EBU 4.5)
LA6EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA6JL30 (JL 3.0)
LA6JL35 (JL 3.5)
LA6JL40 (JL 4.0)
LA6JL45 (JL 4.5)
LA6JL50 (JL 5.0)
LA6JL60 (JL 6.0)
JR@ (Judkin Right )
LA6JR30 (JR 3.0)
LA6JR35 (JR 3.5)
LA6JR40 (JR 4.0)
LA6JR45 (JR 4.5)
LA6JR50 (JR 5.0)
LA6JR60 (JR 6.0)
AL@ (Amplatz Left )
LA6AL75 (AL .75)
LA6AL10 (AL 1.0)
LA6AL15 (AL 1.5)
LA6AL20 (AL 2.0)
LA6AL25 (AL 2.5)
LA6AL30 (AL 3.0)
LA6AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA6SAL75 (SAL . 75)
LA6SAL10 (SAL 1.0)
LA6SAL15 (SAL 1.5)
LA6SAL20 (SAL 2.0)
LA6SAL25 (SAL 2.5)
LA6SAL30 (SAL 3.0)
LA6SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA6AR10 (AR 1.0)
LA6AR20 (AR 2.0)
LA6ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA6ECR35 (ECR 3.5)
LA6ECR40 (ECR 4.0)
LA6ECR45 (ECR 4.5)
LA6RBU35 (RBU 3.5)
LA6RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA6SCR35 (SCR 3.5)
LA6SCR40 (SCR 4.0)
LA6SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA6SAR10 (SAR 1.0)
LA6SAR20 (SAR 2.0)
Multipurpose@
LA6MB1 (MB 1)
LA6MB2 (MB 2)
LA6HSREL (Hockey Stick)
LA6HSI (Hockey I)
LA6HSII (Hockey II)
LA6HSIII (Hockey III)
Bypass Crafts@
LA6LCB (LCB)
LA6RCB (RCB)
LA6RCB (RCB III)
LA6RCB (RCBÂ 90cm)
LA6IMA (IMA)
LA6IMA (IMAÂ 90cm)
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.ÂOPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitors -
NC Sprinter PTCA BALLOON
NC Sprinter RX Noncompliant
NC Stormer over-the-wire noncompliant balloon dilatation catheter offers controlled compliance, high pressures, and comprehensive lengths.
Balloon Dilatation Catheter
OVERVIEW
The NC Sprinterâ„¢ RX noncompliant coronary balloon combines:
- Sprinter crossing technology
- High-pressure capability and controlled expansion1
ORDERING INFORMATION
BALLOON LENGTHS 6, 9, 12 MM
Balloon Diameter (mm)
Balloon Length (mm)     6 9 12 2.00 NCSP2006X NCSP2009X NCSP2012X 2.25 NCSP22506X — NCSP22512X 2.50 NCSP2506X NCSP2509X NCSP2512X 2.75 NCSP27506X NCSP27509X NCSP27512X 3.00 NCSP3006X NCSP3009X NCSP3012X 3.25 NCSP32506X NCSP32509X NCSP32512X 3.50 NCSP3506X NCSP3509X NCSP3512X 3.75 NCSP37506X NCSP37509X NCSP37512X 4.00 NCSP4006X NCSP4009X NCSP4012X 4.50 — — — 5.00 — — — BALLOON LENGTHS 15, 21, 27 MM
Balloon Diameter (mm)
Balloon Length (mm)     15 21 27 2.00 NCSP2015X NCSP2021X — 2.25 — NCSP22521X — 2.50 NCSP2515X NCSP2521X NCSP2527X 2.75 NCSP27515X NCSP27521X — 3.00 NCSP3015X NCSP3021X NCSP3027X 3.25 NCSP32515X NCSP32521X — 3.50 NCSP3515X NCSP3521X NCSP3527X 3.75 NCSP37515X NCSP37521X — 4.00 NCSP4015X NCSP4021X NCSP4027X 4.50 NCSP4515X NCSP4521X — 5.00 NCSP5015X — —









Reviews
There are no reviews yet.