PROGREAT® MICROCATHETHER
PRODUCT OVERVIEW
PROGREAT® Microcatheters are designed to allow navigation through tortuous peripheral vessels for optimal access and delivery of therapeutic embolization.
Terumo Progreat 2.7Fr. Microcatheter is Designed to provide optimal trackability and support even in the most tortuous anatomy.
DESIGNED TO CONFIDENTLY DELIVER EMBOLOTHERAPY
- Tungsten coil reinforcement for kink resistance2
- PTFE inner layer is designed for exceptional guidewire tracking, with virtually frictionless delivery of coils and other embolics2
- DMSO Compatible3
- Radiopaque 0.7 mm platinum/iridium markers allow for rapid and precise positioning4

DESIGNED TO ENHANCE ACCESS TO SMALL PERIPHERAL VESSELS
- TERUMO Glide TechnologyTM hydrophilic coating enhances navigation through tortuous anatomy1,2
- Unique varied tungsten coil pitch construction provides distal flexibility and proximal pushability, enhancing vessel selectivity and catheter placement.

PROGREAT® COAXIAL MICROCATHETER SYSTEM
- Preloaded with uniquely designed 0.021” GLIDEWIRE® GT for the 2.8Fr system and 0.018″ GLIDEWIRE® GT for the 2.4Fr system1
- Available in 2.8Fr and 2.4Fr
- Enables simultaneous preparation of microcatheter and guidewire, which may save time and increase procedural efficiency1
PROGREAT 2.4 COAXIAL PROVEN TO REACH DISTAL VESSELS WITH EASE⁴
- Provides greater vessel selectivity and demonstrated superiority in traversing tortuous anatomy
- Provides best-in-class kink resistance, demonstrated in both the distal and proximal shaft.

PROGREAT® Microcatheter Product Codes
Includes hemostatic valve and shaping mandrel
| Fr Size | Product Code | Length (cm) | Tip Shape | Max Pressure (psi) | RO Markers | Hydrophilic Coating Length (cm) |
| 2.4 | MC*PB2411Y | 110 | Straight | 750 | 1 | 50 |
| MC*PB2413Y | 130 | Straight | 1 | 70 | ||
| MC*PB2413ZRA | 130 | 70 Deg. Angle | 1 | 70 | ||
| MC*PB2413ZRC | 130 | J Curve | 1 | 70 | ||
| MC*PV2415Y | 150 | Straight | 2 | 90 | ||
| MC*PV2415ZRA | 150 | 70 Deg. Angle | 2 | 90 | ||
| MC*PV2415ZRC | 150 | J Curve | 2 | 90 | ||
| 2.7 | MC*PC2711Y | 110 | Straight | 750 | – | 50 |
| MC*PC27137 | 130 | Straight | – | 70 | ||
| 2.8 | MC*PB2811Y | 110 | Straight | 900 | 1 | 50 |
| MC*PB2813Y | 130 | Straight | 1 | 70 | ||
| MC*PV2815Y | 150 | Straight | 2 | 90 |
PROGREAT® Coaxial Microcatheter System Codes
Includes unique GLIDEWIRE® GT Guidewire, wire stopper, guidewire introducer, hemostatic valve, 2.5 mL syringe, and shaping mandrel
| Fr Size | Product Code |
Length (cm) |
Max Pressure (PSI) |
RO Markers | Hydrophilic Coating Length (cm) |
Glidewire® GT Length (cm) |
Glidewire® GT Size (in) |
| 2.4 Fr | MC*PE24111YB | 110 | 750 | 1 | 50 | 120 | 0.018 |
| 2.4 Fr | MC*PE24131YB | 130 | 750 | 1 | 70 | 140 | 0.018 |
| 2.4 Fr | MC*PE24151YV | 150 | 750 | 2 | 90 | 160 | 0.018 |
| 2.7 Fr | MC*PE27111Y | 110 | 750 | – | 50 | 120 | 0.021 |
| 2.7 Fr | MC*PE27131Y | 130 | 750 | – | 70 | 140 | 0.021 |
| 2.8 Fr | MC*PE28111YB | 110 | 900 | 1 | 50 | 120 | 0.021 |
| 2.8 Fr | MC*PE28131YB | 130 | 900 | 1 | 70 | 140 | 0.021 |
| 2.8 Fr | MC*PE28151YV | 150 | 900 | 2 | 90 | 160 | 0.021 |
PRODUCT SPECIFICATIONS
| Catheter OD | Length (cm) |
Inner Diameter (in/mm) |
Max GW (in) |
Embolic Compatibility |
Dead Space Volume (mL) |
Actual Flow Rate* (mL/sec) @ 750 psi | Actual Flow Rate* (mL/sec) @ 900 psi |
| 2.4/2.9Fr (0.80/0.97mm) |
110 | 0.022″/0.57 | 0.018″ | 0.018″ Coils/HydroPearl® 600 ± 75 μm |
0.48 | 2.3 | – |
| 2.4/2.9Fr (0.80/0.97mm) |
130 | 0.022″/0.57 | 0.018″ | 0.018″ Coils/HydroPearl® 600 ± 75 μm |
0.53 | 2 | – |
| 2.4/2.9Fr (0.80/0.97mm) |
150 | 0.022″/0.57 | 0.018″ | 0.018″ Coils/HydroPearl® 600 ± 75 μm |
0.58 | 1.8 | – |
| 2.7/2.9Fr (0.90/0.97mm) |
110 | 0.025″/0.065 | 0.021″ | 0.018″ Coils/HydroPearl® 800 ± 75 μm |
0.57 | 3.5 | – |
| 2.7/2.9Fr (0.90/0.97mm) |
130 | 0.025″/0.065 | 0.021″ | 0.018″ Coils/HydroPearl® 800 ± 75 μm |
0.64 | 3.2 | – |
| 2.8/3.0Fr (0.93/1.00mm) |
110 | 0.027″/0.70 | 0.021″ | 0.018″ Coils/HydroPearl® 800 ± 75 μm |
0.61 | 4.1 | 4.7 |
| 2.8/3.0Fr (0.93/1.00mm) |
130 | 0.027″/0.70 | 0.021″ | 0.018″ Coils/HydroPearl® 800 ± 75 μm |
0.68 | 3.7 | 4.3 |
| 2.8/3.0Fr (0.93/1.00mm) |
150 | 0.027″/0.70 | 0.021″ | 0.018″ Coils/HydroPearl® 800 ± 75 μm |
0.75 | 3.1 | 3.9 |
REFERENCES
RX ONLY. Refer to the product labels and package insert for complete warnings, precautions, potential complications, and instructions for use.
- Catheter [Instructions for Use]. Somerset, NJ: Terumo Medical Corporation; 2016
- PROGREAT Catheter 510(k); 2003
- PROGREAT DMSO Compatibility Statement Letter
- Data on file.
PROGREAT® MICROCATHETHER
2 reviews for PROGREAT® MICROCATHETHER
Related products
-
Launcher- 6f Guiding Catheter’s
EBU@ (Extra Backup)
LA6EBU30 (EBU 3.0)
LA6EBU35 (EBU 3.5)
LA6EBU375 (EBU 3.75)
LA6EBU40 (EBU 4.0)
LA6EBU45 (EBU 4.5)
LA6EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA6JL30 (JL 3.0)
LA6JL35 (JL 3.5)
LA6JL40 (JL 4.0)
LA6JL45 (JL 4.5)
LA6JL50 (JL 5.0)
LA6JL60 (JL 6.0)
JR@ (Judkin Right )
LA6JR30 (JR 3.0)
LA6JR35 (JR 3.5)
LA6JR40 (JR 4.0)
LA6JR45 (JR 4.5)
LA6JR50 (JR 5.0)
LA6JR60 (JR 6.0)
AL@ (Amplatz Left )
LA6AL75 (AL .75)
LA6AL10 (AL 1.0)
LA6AL15 (AL 1.5)
LA6AL20 (AL 2.0)
LA6AL25 (AL 2.5)
LA6AL30 (AL 3.0)
LA6AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA6SAL75 (SAL . 75)
LA6SAL10 (SAL 1.0)
LA6SAL15 (SAL 1.5)
LA6SAL20 (SAL 2.0)
LA6SAL25 (SAL 2.5)
LA6SAL30 (SAL 3.0)
LA6SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA6AR10 (AR 1.0)
LA6AR20 (AR 2.0)
LA6ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA6ECR35 (ECR 3.5)
LA6ECR40 (ECR 4.0)
LA6ECR45 (ECR 4.5)
LA6RBU35 (RBU 3.5)
LA6RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA6SCR35 (SCR 3.5)
LA6SCR40 (SCR 4.0)
LA6SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA6SAR10 (SAR 1.0)
LA6SAR20 (SAR 2.0)
Multipurpose@
LA6MB1 (MB 1)
LA6MB2 (MB 2)
LA6HSREL (Hockey Stick)
LA6HSI (Hockey I)
LA6HSII (Hockey II)
LA6HSIII (Hockey III)
Bypass Crafts@
LA6LCB (LCB)
LA6RCB (RCB)
LA6RCB (RCB III)
LA6RCB (RCB 90cm)
LA6IMA (IMA)
LA6IMA (IMA 90cm)
-
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILS†
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.†
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.†
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ™Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export™ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export™ AP aspiration catheter without stylet.
-
Launcher- 7f Guiding Catheter’s
EBU@ (Extra Backup)
LA7EBU30 (EBU 3.0)
LA7EBU35 (EBU 3.5)
LA7EBU375 (EBU 3.75)
LA7EBU40 (EBU 4.0)
LA7EBU45 (EBU 4.5)
LA7EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA7JL30 (JL 3.0)
LA7JL35 (JL 3.5)
LA7JL40 (JL 4.0)
LA7JL45 (JL 4.5)
LA7JL50 (JL 5.0)
LA7JL60 (JL 6.0)
JR@ (Judkin Right )
LA7JR30 (JR 3.0)
LA7JR35 (JR 3.5)
LA7JR40 (JR 4.0)
LA7JR45 (JR 4.5)
LA7JR50 (JR 5.0)
LA7JR60 (JR 6.0)
AL@ (Amplatz Left )
LA7AL75 (AL .75)
LA7AL10 (AL 1.0)
LA7AL15 (AL 1.5)
LA7AL20 (AL 2.0)
LA7AL25 (AL 2.5)
LA7AL30 (AL 3.0)
LA7AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA7SAL75 (SAL . 75)
LA7SAL10 (SAL 1.0)
LA7SAL15 (SAL 1.5)
LA7SAL20 (SAL 2.0)
LA7SAL25 (SAL 2.5)
LA7SAL30 (SAL 3.0)
LA7SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA7AR10 (AR 1.0)
LA7AR20 (AR 2.0)
LA7ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA7ECR35 (ECR 3.5)
LA7ECR40 (ECR 4.0)
LA7ECR45 (ECR 4.5)
LA7RBU35 (RBU 3.5)
LA7RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA7SCR35 (SCR 3.5)
LA7SCR40 (SCR 4.0)
LA7SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA7SAR10 (SAR 1.0)
LA7SAR20 (SAR 2.0)
Multipurpose@
LA7MB1 (MB 1)
LA7MB2 (MB 2)
LA7HSREL (Hockey Stick)
LA7HSI (Hockey I)
LA7HSII (Hockey II)
LA7HSIII (Hockey III)
Bypass Crafts@
LA7LCB (LCB)
LA7RCB (RCB)
LA7RCB (RCB III)
LA7RCB (RCB 90cm)
LA7IMA (IMA)
LA7IMA (IMA 90cm)
-
ACT CARTRIDGE (HR-ACT)
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
SKU:402-03Weight:3.00 LBSAvailability:2-3 Business daysShipping:Calculated at checkoutQuantity:Product Description
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box 402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box 402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box 402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box









35.01hvm0nt6jqdj62j0vs9tf1cmp@mail4u.fun –
nihil quisquam magni hic pariatur magni itaque voluptas voluptatum quia ad mollitia veniam et autem magni consequatur labore et rerum autem. quia quos sequi rem ea explicabo id quisquam. perspiciatis
Quiernera –
At higher concentrations, inhibition was observed buy priligy online