PRESSURE MONITORING KIT
PRESSURE MONITORING SET SINGAL LANTH (PX260)(PX284)
Accurate and safe pressure monitoring – TruWave disposable pressure transducers may be used independently or combined with VAMP closed blood sampling systems for a single safe, reliable and accurate monitoring solution.
Adult transducers
Our standard TruWave pressure monitoring kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.
Single
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Single TruWave disposable pressure transducer with 3 cc flush device and IV set; tubing length and color options available
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.
Double
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Two TruWave disposable pressure transducers with
3 cc flush device and bifurcated IV set; tubing length and color options available
Triple
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Three TruWave disposable pressure transducers with 3 cc flush device and trifurcated IV set; tubing length and color options available
Pediatric transducers
Accuracy for your patients
Our pediatric TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. Pediatric TruWave transducers can be paired with the VAMP Jr. system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Single TruWave disposable pressure transducer, 30 cc flush device (to be used with a mechanical infusion pump); tubing length options available
Flushless transducers
Accuracy for your patients
Our TruWave flushless disposable pressure monitoring transducers are designed for intracranial pressure monitoring.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Single TruWave disposable pressure transducer without a flush device
Cables
Connecting your TruWave pressure monitoring transducers is simplified with Edwards multi-channel pressure cables.
The streamlined design eliminates clutter and confusion. Available in single, bifurcated (2-in-1) and trifurcated (3-in-1) configurations with color-coded ends for easy setup: the right number of lines for the right patient. Contact your Edwards sales representative for the appropriate cable part number to connect your TruWave transducer to the bedside monitor.

Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| PX1800 | Reusable cable | Each |
Holders and mounts
TruWave disposable pressure transducer accessories
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| TCLIP05 | Reusable holder for DPT | CS(5) |
| DTSS | PKG accessory – arm strap | CS(10) |
| DTSC | IV pole clamp for model DTH4 backplate hold | Each |
Â
Pressure tubing
TruWave disposable pressure transducer tubing
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| 50P106 | Male / female connectors, 6″ long | CS(20) |
| 50P112 | Male / female connectors, 12″ long | CS(20) |
| 50P124 | Male / female connectors, 24″ long | CS(20) |
| 50P136 | Male / female connectors, 36″ long | CS(20) |
| 50P148 | Male / female connectors, 48″ long | CS(20) |
| 50P160 | Male / female connectors, 60″ long | CS(20) |
| 50P172 | Male / female connectors, 72″ long | CS(20) |
| 50P184 | Male / female connectors, 84″ long | CS(20) |
| 50P200R | Male / male luer lock adapter with rotating nut | CS(20) |
| 50P206 | Male / male connectors, 6″ long | CS(20) |
| 50P212 | Male / male connectors, 12″ long | CS(20) |
| 50P224 | Male / male connectors, 24″ long | CS(20) |
| 50P236 | Male / male connectors, 36″ long | CS(20) |
| 50P248 | Male / male connectors, 48″ long | CS(20) |
| 50P260 | Male / male connectors, 60″ long | CS(20) |
| 50P272 | Male / male connectors, 72″ long | CS(20) |
| 50P284 | Male / male connectors, 84″ long | CS(20) |
Stopcocks and caps
TruWave disposable pressure transducer stopcocks and caps
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| 591WSC | One-way sterile stopcock | CS(50) |
| 593WSC | Three-way sterile stopcock | CS(50) |
| 59L3WSC | Lipid resistant 3-way stopcock | CS(20) |
Related products
-
PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- ​Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
Shaft diameter 1.9 Fr / 0.64Â mm Proximal
2.5 Fr / 0.84 mm Mid
2.6 Fr / 0.86 mm DistalUsable length 145 cm Balloon markers 2 Nominal pressure 12 atm / 1216 kPa Rated burst pressure 22 atm / 2229 kPa (2.0 mm to 4.0 mm)
20 atm / 2026 kPa (4.5 and 5.0 mm)Guidewire compatibility Maximum diameter 0.014″ / 0.36 mm Lesion entry profile 0.43 mm Coating Hydrophilic Item specifications
Ordering Information
Balloon
diameter
(mm) ​Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​ 6 8 12 15 20 25 30 2.00 DC-RM2006HSW DC-RM2008HSW DC-RM2012HHW DC-RM2015HHW DC-RM2020HHW — — 2.25 DC-RM2206HSW DC-RM2208HSW DC-RM2212HHW DC-RM2215HHW DC-RM2220HHW — — 2.50 DC-RM2506HSW DC-RM2508HSW DC-RM2512HHW DC-RM2515HHW DC-RM2520HHW DC-RM2525HHW DC-RM2530HHW 2.75 DC-RM2706HSW DC-RM2708HSW DC-RM2712HHW DC-RM2715HHW DC-RM2720HHW — — 3.00 DC-RM3006HSW DC-RM3008HSW DC-RM3012HHW DC-RM3015HHW DC-RM3020HHW DC-RM3025HHW DC-RM3030HHW 3.25 DC-RM3206HSW DC-RM3208HSW DC-RM3212HHW DC-RM3215HHW DC-RM3220HHW — — 3.50 DC-RM3506HSW DC-RM3508HSW DC-RM3512HHW DC-RM3515HHW DC-RM3520HHW DC-RM3525HHW DC-RM3530HHW 3.75 DC-RM3706HSW DC-RM3708HSW DC-RM3712HHW DC-RM3715HHW DC-RM3720HHW — — 4.00 DC-RM4006HSW DC-RM4008HSW DC-RM4012HHW DC-RM4015HHW DC-RM4020HHW — — 4.50 DC-RM4506HSW DC-RM4508HSW DC-RM4512HSW DC-RM4515HSW — — — 5.00 DC-RM5006HSW DC-RM5008HSW DC-RM5012HSW DC-RM5015HSW — — — Please quote above item reference codes when placing an order.
Balloon Compliance
Balloon
diameter
(mm) ​Pressure (atm) ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2.00 1.58 1.65 1.72 1.79 1.84 1.88 1.92 1.95 1.98 2.00* 2.01 2.03 2.04 2.05 2.06 2.08 2.09 2.10 2.12 2.13** 2.14 2.15 2.17 2.25 1.96 2.01 2.06 2.11 2.14 2.16 2.19 2.21 2.23 2.25* 2.26 2.28 2.29 2.31 2.32 2.34 2.35 2.36 2.38 2.39** 2.41 2.42 2.44 2.50 2.19 2.24 2.30 2.36 2.38 2.41 2.44 2.46 2.48 2.50* 2.52 2.53 2.55 2.56 2.58 2.60 2.61 2.63 2.64 2.66** 2.68 2.69 2.71 2.75 2.43 2.48 2.53 2.59 2.62 2.65 2.67 2.70 2.73 2.75* 2.77 2.79 2.80 2.82 2.84 2.86 2.87 2.89 2.91 2.93** 2.94 2.96 2.98 3.00 2.65 2.71 2.76 2.82 2.85 2.89 2.92 2.95 2.97 3.00* 3.02 3.04 3.06 3.08 3.10 3.11 3.13 3.15 3.17 3.19** 3.21 3.23 3.25 3.25 2.89 2.95 3.01 3.07 3.10 3.14 3.17 3.20 3.22 3.25* 3.27 3.29 3.31 3.33 3.35 3.37 3.39 3.42 3.44 3.46** 3.47 3.48 3.51 3.50 3.13 3.19 3.26 3.32 3.35 3.39 3.42 3.45 3.47 3.50* 3.52 3.54 3.57 3.59 3.61 3.63 3.65 3.68 3.70 3.72** 3.74 3.74 3.76 3.75 3.37 3.44 3.50 3.56 3.60 3.63 3.66 3.69 3.72 3.75* 3.77 3.80 3.82 3.84 3.86 3.88 3.90 3.92 3.94 3.96** 3.98 3.99 4.01 4.00 3.58 3.65 3.72 3.79 3.83 3.87 3.90 3.94 3.97 4.00* 4.03 4.05 4.07 4.09 4.11 4.13 4.15 4.17 4.19 4.21** 4.23 4.26 4.28 4.50 4.02 4.10 4.19 4.28 4.32 4.37 4.40 4.44 4.47 4.50* 4.53 4.56 4.59 4.63 4.66 4.68 4.71 4.75** 4.78 4.81 4.84 4.87 4.91 5.00 4.52 4.59 4.67 4.75 4.80 4.85 4.89 4.93 4.96 5.00* 5.03 5.07 5.10 5.13 5.16 5.19 5.22 5.26** 5.29 5.32 5.35 5.38 5.41 * Nominal pressure
** Rated burst pressureReferences
​​1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Ordering Information. Balloon diameter (mm) ​, Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​.Balloon markers: 2Usable length: 145 cmCoating: HydrophilicLesion entry profile: 0.43 mmStraight-Single Latex Plastic Terumo Accuforce Balloon Catheter, Size: Medium ; Application, Hospital ; Brand, Terumo ; Material, Latex ; Inner Diameter, 36mm. -
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILSâ€
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.â€
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.â€
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - â„¢Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Exportâ„¢ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Exportâ„¢ AP aspiration catheter without stylet.
-
RADIFOCUS REDIAL SHEATH
Providing you the best range of Terumo Radifocus Radial Introducer Sheath and Cordis Femoral Introducer Sheath with effective & timely delivery.
The radial artery access sheath is used to gain arterial access and facilitate the insertion of catheters or other equipment for diagnostic and vascular interventions.
- The Cordis AVANTI®+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI®+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates procedural flexibility. It stays in place and allows patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and helps to minimize damage upon entry.
As part of the circulatory system, the radial artery supplies blood from the heart to the forearm.
Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.
-
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.









national pharmacies online –
This is a topic that’s near to my heart… Cheers! Where are your contact details though?
Quiernera –
buy tizanidine pills purchase metoclopramide online cheap buy metoclopramide 20mg pills can i buy priligy in usa my onc said if this was happening to his wife, he would want her to do it
Quiernera –
In keeping with this, TIMP 1 tissue inhibitor of metalloproteinases 1 and TIMP 2, which down regulate MMPs, increased after EGCG treatment free samples of priligy