PRESSURE MONITORING KIT
PRESSURE MONITORING SET SINGAL LANTH (PX260)(PX284)
Accurate and safe pressure monitoring – TruWave disposable pressure transducers may be used independently or combined with VAMP closed blood sampling systems for a single safe, reliable and accurate monitoring solution.
Adult transducers
Our standard TruWave pressure monitoring kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.
Single
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Single TruWave disposable pressure transducer with 3 cc flush device and IV set; tubing length and color options available
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.
Double
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Two TruWave disposable pressure transducers with
3 cc flush device and bifurcated IV set; tubing length and color options available
Triple
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Three TruWave disposable pressure transducers with 3 cc flush device and trifurcated IV set; tubing length and color options available
Pediatric transducers
Accuracy for your patients
Our pediatric TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. Pediatric TruWave transducers can be paired with the VAMP Jr. system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Single TruWave disposable pressure transducer, 30 cc flush device (to be used with a mechanical infusion pump); tubing length options available
Flushless transducers
Accuracy for your patients
Our TruWave flushless disposable pressure monitoring transducers are designed for intracranial pressure monitoring.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Single TruWave disposable pressure transducer without a flush device
Cables
Connecting your TruWave pressure monitoring transducers is simplified with Edwards multi-channel pressure cables.
The streamlined design eliminates clutter and confusion. Available in single, bifurcated (2-in-1) and trifurcated (3-in-1) configurations with color-coded ends for easy setup: the right number of lines for the right patient. Contact your Edwards sales representative for the appropriate cable part number to connect your TruWave transducer to the bedside monitor.

Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| PX1800 | Reusable cable | Each |
Holders and mounts
TruWave disposable pressure transducer accessories
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| TCLIP05 | Reusable holder for DPT | CS(5) |
| DTSS | PKG accessory – arm strap | CS(10) |
| DTSC | IV pole clamp for model DTH4 backplate hold | Each |
Â
Pressure tubing
TruWave disposable pressure transducer tubing
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| 50P106 | Male / female connectors, 6″ long | CS(20) |
| 50P112 | Male / female connectors, 12″ long | CS(20) |
| 50P124 | Male / female connectors, 24″ long | CS(20) |
| 50P136 | Male / female connectors, 36″ long | CS(20) |
| 50P148 | Male / female connectors, 48″ long | CS(20) |
| 50P160 | Male / female connectors, 60″ long | CS(20) |
| 50P172 | Male / female connectors, 72″ long | CS(20) |
| 50P184 | Male / female connectors, 84″ long | CS(20) |
| 50P200R | Male / male luer lock adapter with rotating nut | CS(20) |
| 50P206 | Male / male connectors, 6″ long | CS(20) |
| 50P212 | Male / male connectors, 12″ long | CS(20) |
| 50P224 | Male / male connectors, 24″ long | CS(20) |
| 50P236 | Male / male connectors, 36″ long | CS(20) |
| 50P248 | Male / male connectors, 48″ long | CS(20) |
| 50P260 | Male / male connectors, 60″ long | CS(20) |
| 50P272 | Male / male connectors, 72″ long | CS(20) |
| 50P284 | Male / male connectors, 84″ long | CS(20) |
Stopcocks and caps
TruWave disposable pressure transducer stopcocks and caps
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| 591WSC | One-way sterile stopcock | CS(50) |
| 593WSC | Three-way sterile stopcock | CS(50) |
| 59L3WSC | Lipid resistant 3-way stopcock | CS(20) |
Related products
-
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
-
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS
-
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.ÂOPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitorsÂ









national pharmacies online –
This is a topic that’s near to my heart… Cheers! Where are your contact details though?
Quiernera –
buy tizanidine pills purchase metoclopramide online cheap buy metoclopramide 20mg pills can i buy priligy in usa my onc said if this was happening to his wife, he would want her to do it
Quiernera –
In keeping with this, TIMP 1 tissue inhibitor of metalloproteinases 1 and TIMP 2, which down regulate MMPs, increased after EGCG treatment free samples of priligy