PRESSURE MONITORING KIT
PRESSURE MONITORING SET SINGAL LANTH (PX260)(PX284)
Accurate and safe pressure monitoring – TruWave disposable pressure transducers may be used independently or combined with VAMP closed blood sampling systems for a single safe, reliable and accurate monitoring solution.
Adult transducers
Our standard TruWave pressure monitoring kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.
Single
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Single TruWave disposable pressure transducer with 3 cc flush device and IV set; tubing length and color options available
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.
Double
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Two TruWave disposable pressure transducers with
3 cc flush device and bifurcated IV set; tubing length and color options available
Triple
Accuracy for your patients
Our standard TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. TruWave transducer kits can be paired with the VAMP (Venous Arterial Blood Management Protection) system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion
- Gold plated connector wires for high fidelity signal transfer
- Snap-tab flush device designed for easy priming and square-wave testing

Three TruWave disposable pressure transducers with 3 cc flush device and trifurcated IV set; tubing length and color options available
Pediatric transducers
Accuracy for your patients
Our pediatric TruWave pressure monitoring transducer kits are sterile, single-use kits that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system. Pediatric TruWave transducers can be paired with the VAMP Jr. system for a single safe, reliable and accurate monitoring solution.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Single TruWave disposable pressure transducer, 30 cc flush device (to be used with a mechanical infusion pump); tubing length options available
Flushless transducers
Accuracy for your patients
Our TruWave flushless disposable pressure monitoring transducers are designed for intracranial pressure monitoring.
- Available in multiple configurations to meet your clinical needs
- Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Single TruWave disposable pressure transducer without a flush device
Cables
Connecting your TruWave pressure monitoring transducers is simplified with Edwards multi-channel pressure cables.
The streamlined design eliminates clutter and confusion. Available in single, bifurcated (2-in-1) and trifurcated (3-in-1) configurations with color-coded ends for easy setup: the right number of lines for the right patient. Contact your Edwards sales representative for the appropriate cable part number to connect your TruWave transducer to the bedside monitor.

Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| PX1800 | Reusable cable | Each |
Holders and mounts
TruWave disposable pressure transducer accessories
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| TCLIP05 | Reusable holder for DPT | CS(5) |
| DTSS | PKG accessory – arm strap | CS(10) |
| DTSC | IV pole clamp for model DTH4 backplate hold | Each |
Pressure tubing
TruWave disposable pressure transducer tubing
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| 50P106 | Male / female connectors, 6″ long | CS(20) |
| 50P112 | Male / female connectors, 12″ long | CS(20) |
| 50P124 | Male / female connectors, 24″ long | CS(20) |
| 50P136 | Male / female connectors, 36″ long | CS(20) |
| 50P148 | Male / female connectors, 48″ long | CS(20) |
| 50P160 | Male / female connectors, 60″ long | CS(20) |
| 50P172 | Male / female connectors, 72″ long | CS(20) |
| 50P184 | Male / female connectors, 84″ long | CS(20) |
| 50P200R | Male / male luer lock adapter with rotating nut | CS(20) |
| 50P206 | Male / male connectors, 6″ long | CS(20) |
| 50P212 | Male / male connectors, 12″ long | CS(20) |
| 50P224 | Male / male connectors, 24″ long | CS(20) |
| 50P236 | Male / male connectors, 36″ long | CS(20) |
| 50P248 | Male / male connectors, 48″ long | CS(20) |
| 50P260 | Male / male connectors, 60″ long | CS(20) |
| 50P272 | Male / male connectors, 72″ long | CS(20) |
| 50P284 | Male / male connectors, 84″ long | CS(20) |
Stopcocks and caps
TruWave disposable pressure transducer stopcocks and caps
Model numbers
| Model | Description | Unit of Measure |
|---|---|---|
| 591WSC | One-way sterile stopcock | CS(50) |
| 593WSC | Three-way sterile stopcock | CS(50) |
| 59L3WSC | Lipid resistant 3-way stopcock | CS(20) |
Related products
-
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
-
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinter™ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinter™ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Selective Dura-Trac coating
- 2.5 mm tip
- FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip
-
OCTOPUS TISSUE STABILIZER
Octopus
Tissue Stabilizers
OCTOPUS TISSUE STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS – THE NEXT GENERATION TISSUE STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus™ Evolution – enhanced stability, flexibility, and a lower profile for unlimited positioning options – the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximum stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION – LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizer provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows “toes up” position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 – EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement
-
Launcher- 6f Guiding Catheter’s
EBU@ (Extra Backup)
LA6EBU30 (EBU 3.0)
LA6EBU35 (EBU 3.5)
LA6EBU375 (EBU 3.75)
LA6EBU40 (EBU 4.0)
LA6EBU45 (EBU 4.5)
LA6EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA6JL30 (JL 3.0)
LA6JL35 (JL 3.5)
LA6JL40 (JL 4.0)
LA6JL45 (JL 4.5)
LA6JL50 (JL 5.0)
LA6JL60 (JL 6.0)
JR@ (Judkin Right )
LA6JR30 (JR 3.0)
LA6JR35 (JR 3.5)
LA6JR40 (JR 4.0)
LA6JR45 (JR 4.5)
LA6JR50 (JR 5.0)
LA6JR60 (JR 6.0)
AL@ (Amplatz Left )
LA6AL75 (AL .75)
LA6AL10 (AL 1.0)
LA6AL15 (AL 1.5)
LA6AL20 (AL 2.0)
LA6AL25 (AL 2.5)
LA6AL30 (AL 3.0)
LA6AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA6SAL75 (SAL . 75)
LA6SAL10 (SAL 1.0)
LA6SAL15 (SAL 1.5)
LA6SAL20 (SAL 2.0)
LA6SAL25 (SAL 2.5)
LA6SAL30 (SAL 3.0)
LA6SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA6AR10 (AR 1.0)
LA6AR20 (AR 2.0)
LA6ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA6ECR35 (ECR 3.5)
LA6ECR40 (ECR 4.0)
LA6ECR45 (ECR 4.5)
LA6RBU35 (RBU 3.5)
LA6RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA6SCR35 (SCR 3.5)
LA6SCR40 (SCR 4.0)
LA6SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA6SAR10 (SAR 1.0)
LA6SAR20 (SAR 2.0)
Multipurpose@
LA6MB1 (MB 1)
LA6MB2 (MB 2)
LA6HSREL (Hockey Stick)
LA6HSI (Hockey I)
LA6HSII (Hockey II)
LA6HSIII (Hockey III)
Bypass Crafts@
LA6LCB (LCB)
LA6RCB (RCB)
LA6RCB (RCB III)
LA6RCB (RCB 90cm)
LA6IMA (IMA)
LA6IMA (IMA 90cm)









national pharmacies online –
This is a topic that’s near to my heart… Cheers! Where are your contact details though?
Quiernera –
buy tizanidine pills purchase metoclopramide online cheap buy metoclopramide 20mg pills can i buy priligy in usa my onc said if this was happening to his wife, he would want her to do it
Quiernera –
In keeping with this, TIMP 1 tissue inhibitor of metalloproteinases 1 and TIMP 2, which down regulate MMPs, increased after EGCG treatment free samples of priligy