MULLIN SHEATH 6F-9F
MULLIN SHEATH 6F-9F
Used to introduce balloons, closed and non-tapered end catheters or other diagnostic and interventional devices.
This product line is serviced by the following clinical division(s):
- Peripheral Intervention
The products on this website are available for sale in the United States. Reference Part Numbers are not the same in all countries/regions. For products available in other countries, please choose one of our other websites from the region selector at the top of the site or contact your local Cook Medical representative.
Specifications
| Order Number | Reference Part Number | Instructions for Use (IFU) |
MR Status |
Fr | Length cm |
Accepts Wire Guide Diameter inch |
|---|---|---|---|---|---|---|
| Mullins Design | ||||||
| G11534 | RCFW-5.0-32-48-RB-MTS | N/A | 5 | 48 | .032 | |
| G11258 | RCFW-5.0-35-63-RB-MTS | N/A | 5 | 63 | .035 | |
| G12813 | RCFW-5.0-35-75-RB-MTS | N/A | 5 | 75 | .035 | |
| G10346 | RCFW-6.0-32-48-RB-MTS | N/A | 6 | 48 | .032 | |
| G12340 | RCFW-6.0-35-75-RB-MTS | N/A | 6 | 75 | .035 | |
| G09380 | RCFW-6.0-38-48-RB-MTS | N/A | 6 | 48 | .038 | |
| G08308 | RCFW-6.0-38-63-RB-MTS | N/A | 6 | 63 | .038 | |
| G09532 | RCFW-6.0-38-75-RB-MTS | N/A | 6 | 75 | .038 | |
| G08363 | RCFW-6.0-38-85-RB-MTS | N/A | 6 | 85 | .038 | |
| G09379 | RCFW-7.0-38-48-RB-MTS | N/A | 7 | 48 | .038 | |
| G07816 | RCFW-7.0-38-63-RB-MTS | N/A | 7 | 63 | .038 | |
| G08756 | RCFW-7.0-38-75-RB-MTS | N/A | 7 | 75 | .038 | |
| G08339 | RCFW-7.0-38-85-RB-MTS | N/A | 7 | 85 | .038 | |
| G08133 | RCFW-8.0-38-63-RB-MTS | N/A | 8 | 63 | .038 | |
| G08759 | RCFW-8.0-38-75-RB-MTS | N/A | 8 | 75 | .038 | |
| G08600 | RCFW-8.0-38-85-RB-MTS | N/A | 8 | 85 | .038 | |
| G08835 | RCFW-9.0-38-63-RB-MTS | N/A | 9 | 63 | .038 | |
| G09190 | RCFW-9.0-38-75-RB-MTS | N/A | 9 | 75 | .038 | |
| G08694 | RCFW-9.0-38-85-RB-MTS | N/A | 9 | 85 | .038 | |
| G08834 | RCFW-10.0-38-63-RB-MTS | N/A | 10 | 63 | .038 | |
| G08709 | RCFW-10.0-38-75-RB-MTS | N/A | 10 | 75 | .038 | |
| G08903 | RCFW-10.0-38-85-RB-MTS | N/A | 10 | 85 | .038 | |
| G10011 | RCFW-11.0-38-63-RB-MTS | N/A | 11 | 63 | .038 | |
| G09109 | RCFW-11.0-38-75-RB-MTS | N/A | 11 | 75 | .038 | |
| G09135 | RCFW-11.0-38-85-RB-MTS | N/A | 11 | 85 | .038 | |
| G10012 | RCFW-12.0-38-63-RB-MTS | N/A | 12 | 63 | .038 | |
| G09171 | RCFW-12.0-38-75-RB-MTS | N/A | 12 | 75 | .038 | |
| G09136 | RCFW-12.0-38-85-RB-MTS | N/A | 12 | 85 | .038 | |
| G09172 | RCFW-13.0-38-75-RB-MTS | N/A | 13 | 75 | .038 | |
| G09557 | RCFW-13.0-38-85-RB-MTS | N/A | 13 | 85 | .038 | |
| G12239 | RCFW-14.0-38-63-RB-MTS | N/A | 14 | 63 | .038 | |
| G09210 | RCFW-14.0-38-75-RB-MTS | N/A | 14 | 75 | .038 | |
| G09102 | RCFW-14.0-38-85-RB-MTS | N/A | 14 | 85 | .038 | |
Related products
-
Launcher- 6f Guiding Catheter’s
EBU@ (Extra Backup)
LA6EBU30 (EBU 3.0)
LA6EBU35 (EBU 3.5)
LA6EBU375 (EBU 3.75)
LA6EBU40 (EBU 4.0)
LA6EBU45 (EBU 4.5)
LA6EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA6JL30 (JL 3.0)
LA6JL35 (JL 3.5)
LA6JL40 (JL 4.0)
LA6JL45 (JL 4.5)
LA6JL50 (JL 5.0)
LA6JL60 (JL 6.0)
JR@ (Judkin Right )
LA6JR30 (JR 3.0)
LA6JR35 (JR 3.5)
LA6JR40 (JR 4.0)
LA6JR45 (JR 4.5)
LA6JR50 (JR 5.0)
LA6JR60 (JR 6.0)
AL@ (Amplatz Left )
LA6AL75 (AL .75)
LA6AL10 (AL 1.0)
LA6AL15 (AL 1.5)
LA6AL20 (AL 2.0)
LA6AL25 (AL 2.5)
LA6AL30 (AL 3.0)
LA6AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA6SAL75 (SAL . 75)
LA6SAL10 (SAL 1.0)
LA6SAL15 (SAL 1.5)
LA6SAL20 (SAL 2.0)
LA6SAL25 (SAL 2.5)
LA6SAL30 (SAL 3.0)
LA6SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA6AR10 (AR 1.0)
LA6AR20 (AR 2.0)
LA6ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA6ECR35 (ECR 3.5)
LA6ECR40 (ECR 4.0)
LA6ECR45 (ECR 4.5)
LA6RBU35 (RBU 3.5)
LA6RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA6SCR35 (SCR 3.5)
LA6SCR40 (SCR 4.0)
LA6SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA6SAR10 (SAR 1.0)
LA6SAR20 (SAR 2.0)
Multipurpose@
LA6MB1 (MB 1)
LA6MB2 (MB 2)
LA6HSREL (Hockey Stick)
LA6HSI (Hockey I)
LA6HSII (Hockey II)
LA6HSIII (Hockey III)
Bypass Crafts@
LA6LCB (LCB)
LA6RCB (RCB)
LA6RCB (RCB III)
LA6RCB (RCB 90cm)
LA6IMA (IMA)
LA6IMA (IMA 90cm)
-
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinter™ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinter™ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Selective Dura-Trac coating
- 2.5 mm tip
- FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip
-
ACT CARTRIDGE (HR-ACT)
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
SKU:402-03Weight:3.00 LBSAvailability:2-3 Business daysShipping:Calculated at checkoutQuantity:Product Description
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box 402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box 402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box 402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box -
OCTOPUS TISSUE STABILIZER
Octopus
Tissue Stabilizers
OCTOPUS TISSUE STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS – THE NEXT GENERATION TISSUE STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus™ Evolution – enhanced stability, flexibility, and a lower profile for unlimited positioning options – the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximum stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION – LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizer provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows “toes up” position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 – EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement








Reviews