INFLATION DEVICE
Inflation device:
To be used to inflate and deflate an angioplasty balloon or other interventional device, and to measure the pressure within the balloon. Accute pressure control Stable Perfomance T handle – Easy to hold and quick-release handle
(1)Pressure capability available: 30atm (440psi) &40atm (588psi), gauge accuracy 0.1atm.
(2)Volume: 20 ml syringe volume.
(3)Length30cm 1200psi extension tube .
(4)Luminescent gauge for easy and accurate readings in dimmed lighting.
(5)Clear polycarbonate Barrel with accurate scale for better visualization of bubbles in the device.
(6)Coarse threads and small diameter barrel enable faster inflation.
(7)Medium pressure (500psi) 3 ways stopcock with vented cap.
(8)Ergonomic Handle design enable one-hand operation.
(9)Can be packaged with a wide variety of angioplasty kits and procedure packs – Y connector pack.
Related products
-
TAZUNA BALLOONTazuna®- Semi-Compliant PTCA Balloon Catheter
Tazuna®- Semi-Compliant PTCA Balloon Catheter
Tazuna® rapid exchange PTCA balloon catheter is intended for use during percutaneous transluminal coronary angioplasty (PTCA) for the purpose of improving myocardial blood flow in a localized stenotic lesion of the coronary arteries.
Tazuna is a high performance balloon utilizing a combination of Terumo’s technologies to improve crossability and pushability to treat the most complex lesions.
Shaft diameter 1.9 Fr (0.63 mm) Proximal
2.4 Fr (0.80 mm) Distal for 1.25 mm to 2.00 mm
2.5 Fr (0.83 mm) Distal for 2.25 mm to 3.00 mmUsable length 145 cm Nominal pressure 6 atm (608 kPa) Rated burst pressure 14 atm (1419 kPa) Guidewire compatibility Maximum diameter 0.014″ (0.36 mm) Lesion entry profile 0.40 mm (1.25 mm to 2.25 mm / 10 mm)
0.42 mm (1.25 mm to 2.25 mm / 15 to 20 mm and 2.5 mm, 3.0 mm)Coating Hydrophilic Sizes Available Item Code 1.25/10 TCO01DC-RK1210EH 1.25/15 TCO01DC-RK1215EH 1.5/10 TCO01DC-RK1510EH 1.5/15 TCO01DC-RK1515EH 2.0/10 TCO01DC-RK2010EH 2.0/15 TCO01DC-RK2015EHW 2.0/20 TCO01DC-RK2020EHW 2.5/10 TCO01DC-RK2510EHW 2.5/15 TCO01DC-RK2515EHW 2.5/20 TCO01DC-RK2520EHW 3.0/10 TCO01DC-RK3010EHW 3.0/15 TCO01DC-RK3015EHW 3.0/20 TCO01DC-RK3020EHW -
EMPIRA PTCA BALLOON
Product Description
EMPIRAâ„¢ PTCA Balloons – CordisEMPIRAâ„¢ Pre Dilatation and Post Dilatation PTCA Balloons catheters helps you reach and treat a wide range of lesions with exceptional crossability
EMPIRA™ NC Balloon Catheter delivers crossability & best-in-class controlled growth to a wide range of lesions. EMPIRA™ NC RX PTCA
The Cordis PTCA Balloon Portfolio includes the EMPIRA™ Balloon, which helps to treat a wide range of lesions with exceptional crossability and redressability.The Cordis PTCA Balloon Portfolio includes the EMPIRA™ Balloon, which helps to treat a wide range of lesions with exceptional crossability and redressability.
-
WHISPER MS PTCA GUIDEWIRE
The HI-TORQUE WHISPER guide wire combines the great distal access of a polymer-covered wire with an innovative technological feature for control and performance. It maneuvers easily, even in complex anatomy, with a soft tip designed to promote safety.Many physicians still use Guide Wire M even after 30 years of the initial stage of TRI. Learn more about Terumo’s low invasive devices designed for Transracial Intervention. Thin-Wall Technology. TRI Pioneer. Cost-Effective Products. Pioneer in Radial Access.Coronary guide wires by Abbott addressing a wide variety coronary intervention needs with both workhorse and specialty guide wires.
Our portfolio of Coronary Specialty Guide Wires offer solutions for challenging anatomy and lesions, with a range of … HI-TORQUE WHISPER™ MS Guide Wire
Appropriately enough, it truly was a wire used as a guide. But the origin was from the French and Dutch, and their term for the tension wire they used to secure their structures.
The key features to recognise when selecting a guidewire are:Â (1) tapered tip or not; (2) polymer cover or not; (3) stiffness; and (4) trackability. It is not uncommon to exchange one set of wires for another during a complex procedure, which is done usually through a microcatheter.
WHISPER MS GUIDE WIRE 0.014″ X 190CM, STRAIGHT
- Tip load: 1.0g
- Radiopaque length: 3 cm
- Outside diameter: 0.014″
- Tip Outside diameter: 0.014″
- Coating: Hydrophilic
- Tip style: Core to tip
- Polymer cover: Full Polymer Cover
- Core Material: DURASTEEL Stainless Steel
Guide wires are constructed with a central shaft of stainless steel or nitinol. The shaft tapers to a distal flexible tip spring coil made of platinum or tungsten (see Figure 3). Nitinol core wires are more resistant to kinking than stainless steel core wires but typically have less torque response.
Coronary guide wires are specialized pieces of equipment used to deliver therapies to diseased areas of the coronary arterial system – the vascular pathways responsible for providing the heart muscle with oxygenated blood.
Solid Core Wire: The central wire is encased by a metal ‘spring’ coil. Mandrel Wire: The outer spring coil is at one end. Ribbon Wire: The spring coil encases both the core wire and a ribbon wire.
The guidewire is the device used to guide the catheter into place during CVC insertions. The purpose of a guidewire is to gain access to the blood vessels using a minimally invasive technique.
-
Heartrail® II – PTCA Guiding Catheter
Heartrail® II – PTCA Guiding Catheter
Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
General Specifications
Shaft inner layer material Polytetrafluoroethylene – PTFE Braiding High strength flat wire mesh pattern Inner diameter 5 Fr – 0.059″ (1.50 mm)
6 Fr – 0.071″ (1.80 mm)
7 Fr – 0.081″ (2.06 mm)Usable length 100 cm
120 cm – Heartrail 5 in 6 systemSizes Available Item Code AL Short Tip 6F TCO06GC-F6AL1SON AL0.75/6F TCO06GC-F6AL0G0N AL1.0/6F TCO06GC-F6AL010N BL3.0/6F TCO06GC-F6BL300N BL3.5/6F TCO06GC-F6BL350N BL3.5/7F TCO06GC-F7BL350N BL4.0/6F TCO06GC-F6BL400N IKARI IL 3.5/5F TCO06GC-F5IL350N IKARI IL 3.5/6F TCO06GC-F6IL350N IKARI IL 4.0/6F TCO06GC-F6IL400N IKARI RIGHT 1.5/6F TCO06GC-F6IR150N Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Description
Optimize your challenging procedure
​Heartrail™ II will improve your back-up force when using Ikari curves right and left during transradial interventions or through a 5Fr guiding catheter in 6Fr to increase backup support.
Characteristics
​Heartrail™ II offers dedicated curves for radial access:- Ikari curves right and left are developed to improve your back-up force during TRI via the right radial artery
- Tiger curves are designed to be used for both right and left coronary arteries
Feel the difference with the 5Fr guiding catheter in 6Fr
By inserting a 5 Fr (120 cm with flexible distal portion) into a 6 Fr guiding catheter:
- Provides the back-up support of a 7 Fr guiding catheter with a 6 Fr
- Minimizes puncture size
- Increases your back-up support for an excellent PTCA balloons crossing success rate1
General specifications
Shaft inner layer material Polytetrafluoroethylene – PTFE Braiding High strength flat wire mesh pattern Inner diameter 5 Fr – 0.059″ (1.50 mm)
6 Fr – 0.071″ (1.80 mm)
7 Fr – 0.081″ (2.06 mm)Usable length 100 cm
120 cm – Heartrail 5Fr straight, for 5Fr guiding catheter in 6FrItem specifications
Shape type Shape code 5 Fr 6 Fr 7 Fr Amplatz Left ​ ​ AL 1 GC-K5AL010N GC-K6AL010N GC-K7AL010N AL 2 GC-K5AL020N GC-K6AL020N GC-K7AL020N AL 3 GC-K5AL030N GC-K6AL030N GC-K7AL030N Amplatz Right ​ AR 1 GC-K5AR010N GC-K6AR010N GC-K7AR010N AR 2 GC-K5AR020N GC-K6AR020N GC-K7AR020N Judkins Left ​ ​ ​ ​ ​ JL 3 — GC-K6JL300N — JL 3.5 GC-K5JL350N GC-K6JL350N GC-K7JL350N JL 4 GC-K5JL400N GC-K6JL400N GC-K7JL400N JL 4.5 GC-K5JL450N GC-K6JL450N — JL 5 GC-K5JL500N GC-K6JL500N GC-K7JL500N JL 6 GC-K5JL600N GC-K6JL600N — Judkins Right ​ ​ ​ ​ ​ JR 3 — — — JR 3.5 GC-K5JR350N GC-K6JR300N ​GC-K7JR350N ​JR 3.5 ​— ​GC-K6JR350N — JR 4 GC-K5JR400N GC-K6JR400N GC-K7JR400N JR 4.5 GC-K5JR450N — — JR 5 GC-K5JR500N GC-K6JR500N — ​JR 6 — ​GC-K6JR600N — BackUp for
left coronary ​ ​ ​ ​BL 2.5 — — — BL 3 GC-K5BL300N GC-K6BL300N GC-K7BL300N BL 3.5 GC-K5BL350N GC-K6BL350N GC-K7BL350N BL 4 GC-K5BL400N GC-K6BL400N GC-K7BL400N BL 4.5 GC-K5BL450N GC-K6BL450N GC-K7BL450N BackUp for
right coronary ​BR 3.5 — GC-K6BR350N — BR 4 — GC-K6BR400N — IMA IMA 1.0 GC-K5IMA10N GC-K6IMA10N GC-K7IMA10N ​Multipurpose ​​MPA-Large ​GC-K5MP030N ​​GC-K6MP030N ​GC-K7MP030N ​
Bypass ​​BP-L ​GC-K5BP010N ​​— ​​— BP-R GC-K5BP020N GC-K6BP020N ​​— Ikari-Curve
Left ​ ​ ​IL 3 — GC-K6IL300N — IL 3.5 GC-K5IL350N GC-K6IL350N GC-K7IL350N IL 4 GC-K5IL400N GC-K6IL400N GC-K7IL400N IL 4.5 — GC-K6IL450N — Ikari-Curve
Right ​ ​IR 1 — GC-K6IR100N — IR 1.5 GC-K5IR150N GC-K6IR150N GC-K7IR150N IR 2 GC-K5IR200N GC-K6IR200N GC-K7IR200N Tiger TIG 5 GC-K5TR500N — — ​— ​— ​— ​— ​GC-K7TR500N ​— ​— ​— ​GC-K6MP020N ​— ​— ​— ​— ​GC-K6TR500N ​— ​— ​— ​— ​GC-K6MP010N ​— ​— ​— ​— ​GC-K6MP010N ​— 5Fr guiding catheter in 6Fr ​ Straight GC-K5ST012NQ — —