Heartrail® II – PTCA Guiding Catheter
Heartrail® II – PTCA Guiding Catheter
Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
General Specifications
| Shaft inner layer material | Polytetrafluoroethylene – PTFE |
|---|---|
| Braiding | High strength flat wire mesh pattern |
| Inner diameter | 5 Fr – 0.059″ (1.50 mm) 6 Fr – 0.071″ (1.80 mm) 7 Fr – 0.081″ (2.06 mm) |
| Usable length | 100 cm 120 cm – Heartrail 5 in 6 system |
| Sizes Available | Item Code |
|---|---|
| AL Short Tip 6F | TCO06GC-F6AL1SON |
| AL0.75/6F | TCO06GC-F6AL0G0N |
| AL1.0/6F | TCO06GC-F6AL010N |
| BL3.0/6F | TCO06GC-F6BL300N |
| BL3.5/6F | TCO06GC-F6BL350N |
| BL3.5/7F | TCO06GC-F7BL350N |
| BL4.0/6F | TCO06GC-F6BL400N |
| IKARI IL 3.5/5F | TCO06GC-F5IL350N |
| IKARI IL 3.5/6F | TCO06GC-F6IL350N |
| IKARI IL 4.0/6F | TCO06GC-F6IL400N |
| IKARI RIGHT 1.5/6F | TCO06GC-F6IR150N |
| Sizes Available | Item Code |
|---|---|
| JL3.5/5F | TCO06GC-F5JL350N |
| JL3.5/6F | TCO06GC-F6JL350N |
| JL4.0/6F | TCO06GC-F6JL400N |
| JR3.5/5F | TCO06GC-F5JR350N |
| JR3.5/6F | TCO06GC-F6JR350N |
| JR4.0/5F | TCO06GC-F5JR400N |
| JR4.0/6F | TCO06GC-F6JR400N |
| JR4.0/7F | TCO06GC-F7JR400N |
| MULTIPURPOSE 6F | TCO06GC-F6MP010N |
| TR4.0/6F | TCO06GC-F6TR400N |
Description
Optimize your challenging procedure
Heartrail™ II will improve your back-up force when using Ikari curves right and left during transradial interventions or through a 5Fr guiding catheter in 6Fr to increase backup support.
Characteristics
- Ikari curves right and left are developed to improve your back-up force during TRI via the right radial artery
- Tiger curves are designed to be used for both right and left coronary arteries
Feel the difference with the 5Fr guiding catheter in 6Fr
By inserting a 5 Fr (120 cm with flexible distal portion) into a 6 Fr guiding catheter:
- Provides the back-up support of a 7 Fr guiding catheter with a 6 Fr
- Minimizes puncture size
- Increases your back-up support for an excellent PTCA balloons crossing success rate1
General specifications
| Shaft inner layer material | Polytetrafluoroethylene – PTFE |
|---|---|
| Braiding | High strength flat wire mesh pattern |
| Inner diameter | 5 Fr – 0.059″ (1.50 mm) 6 Fr – 0.071″ (1.80 mm) 7 Fr – 0.081″ (2.06 mm) |
| Usable length | 100 cm 120 cm – Heartrail 5Fr straight, for 5Fr guiding catheter in 6Fr |
Item specifications
| Shape type | Shape code | 5 Fr | 6 Fr | 7 Fr |
|---|---|---|---|---|
| Amplatz Left | AL 1 | GC-K5AL010N | GC-K6AL010N | GC-K7AL010N |
| AL 2 | GC-K5AL020N | GC-K6AL020N | GC-K7AL020N | |
| AL 3 | GC-K5AL030N | GC-K6AL030N | GC-K7AL030N | |
| Amplatz Right | AR 1 | GC-K5AR010N | GC-K6AR010N | GC-K7AR010N |
| AR 2 | GC-K5AR020N | GC-K6AR020N | GC-K7AR020N | |
| Judkins Left | JL 3 | — | GC-K6JL300N | — |
| JL 3.5 | GC-K5JL350N | GC-K6JL350N | GC-K7JL350N | |
| JL 4 | GC-K5JL400N | GC-K6JL400N | GC-K7JL400N | |
| JL 4.5 | GC-K5JL450N | GC-K6JL450N | — | |
| JL 5 | GC-K5JL500N | GC-K6JL500N | GC-K7JL500N | |
| JL 6 | GC-K5JL600N | GC-K6JL600N | — | |
| Judkins Right | JR 3 | — | — | — |
| JR 3.5 | GC-K5JR350N | GC-K6JR300N | GC-K7JR350N | |
| JR 3.5 | — | GC-K6JR350N | — | |
| JR 4 | GC-K5JR400N | GC-K6JR400N | GC-K7JR400N | |
| JR 4.5 | GC-K5JR450N | — | — | |
| JR 5 | GC-K5JR500N | GC-K6JR500N | — | |
| JR 6 | — | GC-K6JR600N | — | |
| BackUp for left coronary |
BL 2.5 | — | — | — |
| BL 3 | GC-K5BL300N | GC-K6BL300N | GC-K7BL300N | |
| BL 3.5 | GC-K5BL350N | GC-K6BL350N | GC-K7BL350N | |
| BL 4 | GC-K5BL400N | GC-K6BL400N | GC-K7BL400N | |
| BL 4.5 | GC-K5BL450N | GC-K6BL450N | GC-K7BL450N | |
| BackUp for right coronary |
BR 3.5 | — | GC-K6BR350N | — |
| BR 4 | — | GC-K6BR400N | — | |
| IMA | IMA 1.0 | GC-K5IMA10N | GC-K6IMA10N | GC-K7IMA10N |
| Multipurpose | MPA-Large | GC-K5MP030N | GC-K6MP030N | GC-K7MP030N |
| Bypass |
BP-L | GC-K5BP010N | — | — |
| BP-R | GC-K5BP020N | GC-K6BP020N | — | |
| Ikari-Curve Left |
IL 3 | — | GC-K6IL300N | — |
| IL 3.5 | GC-K5IL350N | GC-K6IL350N | GC-K7IL350N | |
| IL 4 | GC-K5IL400N | GC-K6IL400N | GC-K7IL400N | |
| IL 4.5 | — | GC-K6IL450N | — | |
| Ikari-Curve Right |
IR 1 | — | GC-K6IR100N | — |
| IR 1.5 | GC-K5IR150N | GC-K6IR150N | GC-K7IR150N | |
| IR 2 | GC-K5IR200N | GC-K6IR200N | GC-K7IR200N | |
| Tiger | TIG 5 | GC-K5TR500N | — | — |
| — | — | — | — | GC-K7TR500N |
| — | — | — | GC-K6MP020N | — |
| — | — | — | GC-K6TR500N | — |
| — | — | — | GC-K6MP010N | — |
| — | — | — | GC-K6MP010N | — |
| 5Fr guiding catheter in 6Fr | Straight | GC-K5ST012NQ | — | — |
Heartrail® II – PTCA Guiding Catheter
Related products
-
OCTOPUS TISSUE STABILIZER
Octopus
Tissue Stabilizers
OCTOPUS TISSUE STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS – THE NEXT GENERATION TISSUE STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus™ Evolution – enhanced stability, flexibility, and a lower profile for unlimited positioning options – the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximum stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION – LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizer provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows “toes up” position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 – EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement
-
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphora™ noncompliant balloon
NC Euphora™ noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora™ noncompliant balloon dilatation catheter has what you’re looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it — so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X NCEUP32508X NCEUP32512X 3.50 NCEUP3506X NCEUP3508X NCEUP3512X 3.75 NCEUP37506X NCEUP37508X NCEUP37512X 4.00 NCEUP4006X NCEUP4008X NCEUP4012X 4.50 — NCEUP4508X NCEUP4512X 5.00 — NCEUP5008X NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X — 2.25 NCEUP22515X NCEUP22520X — 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25 NCEUP32515X NCEUP32520X NCEUP32527X 3.50 NCEUP3515X NCEUP3520X NCEUP3527X 3.75 NCEUP37515X NCEUP37520X NCEUP37527X 4.00 NCEUP4015X NCEUP4020X NCEUP4027X 4.50 NCEUP4515X NCEUP4520X — 5.00 NCEUP5015X — — -
Launcher- 7f Guiding Catheter’s
EBU@ (Extra Backup)
LA7EBU30 (EBU 3.0)
LA7EBU35 (EBU 3.5)
LA7EBU375 (EBU 3.75)
LA7EBU40 (EBU 4.0)
LA7EBU45 (EBU 4.5)
LA7EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA7JL30 (JL 3.0)
LA7JL35 (JL 3.5)
LA7JL40 (JL 4.0)
LA7JL45 (JL 4.5)
LA7JL50 (JL 5.0)
LA7JL60 (JL 6.0)
JR@ (Judkin Right )
LA7JR30 (JR 3.0)
LA7JR35 (JR 3.5)
LA7JR40 (JR 4.0)
LA7JR45 (JR 4.5)
LA7JR50 (JR 5.0)
LA7JR60 (JR 6.0)
AL@ (Amplatz Left )
LA7AL75 (AL .75)
LA7AL10 (AL 1.0)
LA7AL15 (AL 1.5)
LA7AL20 (AL 2.0)
LA7AL25 (AL 2.5)
LA7AL30 (AL 3.0)
LA7AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA7SAL75 (SAL . 75)
LA7SAL10 (SAL 1.0)
LA7SAL15 (SAL 1.5)
LA7SAL20 (SAL 2.0)
LA7SAL25 (SAL 2.5)
LA7SAL30 (SAL 3.0)
LA7SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA7AR10 (AR 1.0)
LA7AR20 (AR 2.0)
LA7ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA7ECR35 (ECR 3.5)
LA7ECR40 (ECR 4.0)
LA7ECR45 (ECR 4.5)
LA7RBU35 (RBU 3.5)
LA7RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA7SCR35 (SCR 3.5)
LA7SCR40 (SCR 4.0)
LA7SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA7SAR10 (SAR 1.0)
LA7SAR20 (SAR 2.0)
Multipurpose@
LA7MB1 (MB 1)
LA7MB2 (MB 2)
LA7HSREL (Hockey Stick)
LA7HSI (Hockey I)
LA7HSII (Hockey II)
LA7HSIII (Hockey III)
Bypass Crafts@
LA7LCB (LCB)
LA7RCB (RCB)
LA7RCB (RCB III)
LA7RCB (RCB 90cm)
LA7IMA (IMA)
LA7IMA (IMA 90cm)
-
Launcher- 8f Guiding Catheter’s
EBU@ (Extra Backup)
LA8EBU30 (EBU 3.0)
LA8EBU35 (EBU 3.5)
LA8EBU375 (EBU 3.75)
LA8EBU40 (EBU 4.0)
LA8EBU45 (EBU 4.5)
LA8EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA8JL30 (JL 3.0)
LA8JL35 (JL 3.5)
LA8JL40 (JL 4.0)
LA8JL45 (JL 4.5)
LA8JL50 (JL 5.0)
LA8JL60 (JL 6.0)
JR@ (Judkin Right )
LA8JR30 (JR 3.0)
LA8JR35 (JR 3.5)
LA8JR40 (JR 4.0)
LA8JR45 (JR 4.5)
LA8JR50 (JR 5.0)
LA8JR60 (JR 6.0)
AL@ (Amplatz Left )
LA8AL75 (AL .75)
LA8AL10 (AL 1.0)
LA8AL15 (AL 1.5)
LA8AL20 (AL 2.0)
LA8AL25 (AL 2.5)
LA8AL30 (AL 3.0)
LA8AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA8SAL75 (SAL . 75)
LA8SAL10 (SAL 1.0)
LA8SAL15 (SAL 1.5)
LA8SAL20 (SAL 2.0)
LA8SAL25 (SAL 2.5)
LA8SAL30 (SAL 3.0)
LA8SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA8AR10 (AR 1.0)
LA8AR20 (AR 2.0)
LA8ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA8ECR35 (ECR 3.5)
LA8ECR40 (ECR 4.0)
LA8ECR45 (ECR 4.5)
LA8RBU35 (RBU 3.5)
LA8RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA8SCR35 (SCR 3.5)
LA8SCR40 (SCR 4.0)
LA8SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA8SAR10 (SAR 1.0)
LA8SAR20 (SAR 2.0)
Multipurpose@
LA8MB1 (MB 1)
LA8MB2 (MB 2)
LA8HSREL (Hockey Stick)
LA8HSI (Hockey I)
LA8HSII (Hockey II)
LA8HSIII (Hockey III)
Bypass Crafts@
LA8LCB (LCB)
LA8RCB (RCB)
LA8RCB (RCB III)
LA8RCB (RCB 90cm)
LA8IMA (IMA)
LA8IMA (IMA 90cm)







Reviews
There are no reviews yet.