Heartrail® II – PTCA Guiding Catheter
Heartrail® II – PTCA Guiding Catheter
Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
General Specifications
| Shaft inner layer material | Polytetrafluoroethylene – PTFE |
|---|---|
| Braiding | High strength flat wire mesh pattern |
| Inner diameter | 5 Fr – 0.059″ (1.50 mm) 6 Fr – 0.071″ (1.80 mm) 7 Fr – 0.081″ (2.06 mm) |
| Usable length | 100 cm 120 cm – Heartrail 5 in 6 system |
| Sizes Available | Item Code |
|---|---|
| AL Short Tip 6F | TCO06GC-F6AL1SON |
| AL0.75/6F | TCO06GC-F6AL0G0N |
| AL1.0/6F | TCO06GC-F6AL010N |
| BL3.0/6F | TCO06GC-F6BL300N |
| BL3.5/6F | TCO06GC-F6BL350N |
| BL3.5/7F | TCO06GC-F7BL350N |
| BL4.0/6F | TCO06GC-F6BL400N |
| IKARI IL 3.5/5F | TCO06GC-F5IL350N |
| IKARI IL 3.5/6F | TCO06GC-F6IL350N |
| IKARI IL 4.0/6F | TCO06GC-F6IL400N |
| IKARI RIGHT 1.5/6F | TCO06GC-F6IR150N |
| Sizes Available | Item Code |
|---|---|
| JL3.5/5F | TCO06GC-F5JL350N |
| JL3.5/6F | TCO06GC-F6JL350N |
| JL4.0/6F | TCO06GC-F6JL400N |
| JR3.5/5F | TCO06GC-F5JR350N |
| JR3.5/6F | TCO06GC-F6JR350N |
| JR4.0/5F | TCO06GC-F5JR400N |
| JR4.0/6F | TCO06GC-F6JR400N |
| JR4.0/7F | TCO06GC-F7JR400N |
| MULTIPURPOSE 6F | TCO06GC-F6MP010N |
| TR4.0/6F | TCO06GC-F6TR400N |
Description
Optimize your challenging procedure
Heartrail™ II will improve your back-up force when using Ikari curves right and left during transradial interventions or through a 5Fr guiding catheter in 6Fr to increase backup support.
Characteristics
- Ikari curves right and left are developed to improve your back-up force during TRI via the right radial artery
- Tiger curves are designed to be used for both right and left coronary arteries
Feel the difference with the 5Fr guiding catheter in 6Fr
By inserting a 5 Fr (120 cm with flexible distal portion) into a 6 Fr guiding catheter:
- Provides the back-up support of a 7 Fr guiding catheter with a 6 Fr
- Minimizes puncture size
- Increases your back-up support for an excellent PTCA balloons crossing success rate1
General specifications
| Shaft inner layer material | Polytetrafluoroethylene – PTFE |
|---|---|
| Braiding | High strength flat wire mesh pattern |
| Inner diameter | 5 Fr – 0.059″ (1.50 mm) 6 Fr – 0.071″ (1.80 mm) 7 Fr – 0.081″ (2.06 mm) |
| Usable length | 100 cm 120 cm – Heartrail 5Fr straight, for 5Fr guiding catheter in 6Fr |
Item specifications
| Shape type | Shape code | 5 Fr | 6 Fr | 7 Fr |
|---|---|---|---|---|
| Amplatz Left | AL 1 | GC-K5AL010N | GC-K6AL010N | GC-K7AL010N |
| AL 2 | GC-K5AL020N | GC-K6AL020N | GC-K7AL020N | |
| AL 3 | GC-K5AL030N | GC-K6AL030N | GC-K7AL030N | |
| Amplatz Right | AR 1 | GC-K5AR010N | GC-K6AR010N | GC-K7AR010N |
| AR 2 | GC-K5AR020N | GC-K6AR020N | GC-K7AR020N | |
| Judkins Left | JL 3 | — | GC-K6JL300N | — |
| JL 3.5 | GC-K5JL350N | GC-K6JL350N | GC-K7JL350N | |
| JL 4 | GC-K5JL400N | GC-K6JL400N | GC-K7JL400N | |
| JL 4.5 | GC-K5JL450N | GC-K6JL450N | — | |
| JL 5 | GC-K5JL500N | GC-K6JL500N | GC-K7JL500N | |
| JL 6 | GC-K5JL600N | GC-K6JL600N | — | |
| Judkins Right | JR 3 | — | — | — |
| JR 3.5 | GC-K5JR350N | GC-K6JR300N | GC-K7JR350N | |
| JR 3.5 | — | GC-K6JR350N | — | |
| JR 4 | GC-K5JR400N | GC-K6JR400N | GC-K7JR400N | |
| JR 4.5 | GC-K5JR450N | — | — | |
| JR 5 | GC-K5JR500N | GC-K6JR500N | — | |
| JR 6 | — | GC-K6JR600N | — | |
| BackUp for left coronary |
BL 2.5 | — | — | — |
| BL 3 | GC-K5BL300N | GC-K6BL300N | GC-K7BL300N | |
| BL 3.5 | GC-K5BL350N | GC-K6BL350N | GC-K7BL350N | |
| BL 4 | GC-K5BL400N | GC-K6BL400N | GC-K7BL400N | |
| BL 4.5 | GC-K5BL450N | GC-K6BL450N | GC-K7BL450N | |
| BackUp for right coronary |
BR 3.5 | — | GC-K6BR350N | — |
| BR 4 | — | GC-K6BR400N | — | |
| IMA | IMA 1.0 | GC-K5IMA10N | GC-K6IMA10N | GC-K7IMA10N |
| Multipurpose | MPA-Large | GC-K5MP030N | GC-K6MP030N | GC-K7MP030N |
| Bypass |
BP-L | GC-K5BP010N | — | — |
| BP-R | GC-K5BP020N | GC-K6BP020N | — | |
| Ikari-Curve Left |
IL 3 | — | GC-K6IL300N | — |
| IL 3.5 | GC-K5IL350N | GC-K6IL350N | GC-K7IL350N | |
| IL 4 | GC-K5IL400N | GC-K6IL400N | GC-K7IL400N | |
| IL 4.5 | — | GC-K6IL450N | — | |
| Ikari-Curve Right |
IR 1 | — | GC-K6IR100N | — |
| IR 1.5 | GC-K5IR150N | GC-K6IR150N | GC-K7IR150N | |
| IR 2 | GC-K5IR200N | GC-K6IR200N | GC-K7IR200N | |
| Tiger | TIG 5 | GC-K5TR500N | — | — |
| — | — | — | — | GC-K7TR500N |
| — | — | — | GC-K6MP020N | — |
| — | — | — | GC-K6TR500N | — |
| — | — | — | GC-K6MP010N | — |
| — | — | — | GC-K6MP010N | — |
| 5Fr guiding catheter in 6Fr | Straight | GC-K5ST012NQ | — | — |
Heartrail® II – PTCA Guiding Catheter
Related products
-
SPRINTER LEGEND PTCA BALLOON
SPRINTER LEGEND 1.25 BALLOON CATHETER
Super Crosser Semi compliant Balloon Dilatation Catheter (RX/OTW)
Sprinter™ Legend™ 1.25 SuperCrosser semicompliant balloon dilatation catheter delivers exceptional crossability to treat today’s challenging lesions.
With innovative crossing technologies and 57 sizes, the Sprinter™ Legend™ RX semicompliant balloon dilatation catheter provides you with the power to cross.
OVERVIEW
During difficult cases, reach for a slim Sprinter™ Legend™ 1.25 mm Super Crosser semi compliant coronary balloon catheter featuring:
- Award-winning* Zerofold technology — no wrapped material and no balloon shoulders
- Low 0.5 mm (0.020 in) crossing profile
- OTW and RX platforms
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
1.25 SPL12506WL SPL12510WL SPL12515WL SPL12520WL Sprinter Legend RX Semi compliant
Balloon Dilatation Catheter
OVERVIEW
Performance You Can Trust
Sprinter™ Legend™ semicompliant balloons help you cross, open, and treat lesions during challenging percutaneous coronary interventions (PCIs), and feature:
- Some of the industry’s lowest crossing profiles1
- Innovative crossing technology
- A broad range of sizes
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
Balloon Diameter (mm)
1.25 SPL12506X SPL12510X SPL12512X SPL12515X 1.50 SPL15006X SPL15010X SPL15012X SPL15015X 2.00 SPL20006X SPL20010X SPL20012X SPL20015X 2.25 SPL22506X SPL22510X SPL22512X SPL22515X 2.50 SPL25006X SPL25010X SPL25012X SPL25015X 2.75 SPL27506X — SPL27512X SPL27515X 3.00 SPL30006X SPL30010X SPL30012X SPL30015X 3.25 — — SPL32512X SPL32515X 3.50 SPL35006X SPL35010X SPL35012X SPL35015X 3.75 — — SPL37512X SPL37515X 4.00 SPL40006X SPL40010X SPL40012X SPL40015X BALLOON LENGTHS 20, 25, AND 30 MM
Balloon Diameter (mm)
1.25 SPL12520X — — 1.50 SPL15020X — — 2.00 SPL20020X SPL20025X SPL20030X 2.25 SPL22520X SPL22525X — 2.50 SPL25020X SPL25025X SPL25030X 2.75 SPL27520X SPL27525X — 3.00 SPL30020X SPL30025X SPL30030X 3.25 SPL32520X — — 3.50 SPL35020X SPL35025X SPL35030X 3.75 SPL37520X — — 4.00 SPL40020X SPL40025X SPL40030X -
CLOSUREFAST
ClosureFast™
procedureMinimally invasive thermal
treatment for vein disease
and varicose veins.
The ClosureFast procedure uses radiofrequency energy or heat to close the diseased vein, which redirects blood flow to healthy veins, relieving symptoms.Before the procedure
You will have an ultrasound imaging exam of the leg being treated. This exam is important for assessing the diseased superficial vein and planning the procedure.
During the procedure
Your doctor will discuss the procedure with you. Here is a brief summary of what to expect:
- The ClosureFast procedure is performed on an outpatient basis. Your doctor will perform the ClosureFast procedure. Using an ultrasound, your doctor will position a catheter in the diseased vein through a small opening in the skin.
- The small catheter delivers heat to the vein wall, causing it to shrink and seal the vein. Once the diseased vein is closed, blood will reroute itself to other healthy veins.
After the procedure
- You will be taken to the recovery area to rest.
- Following the procedure, your doctor will apply a simple bandage over the insertion site and will give you compression stockings to aid in the healing process. Your doctor may encourage you to walk and to refrain from extended standing and strenuous activities for a period of time. The average patient typically resumes normal activities within a few days.1,2
- Your doctor will recommend follow-up care as needed.
-
Benefits of the ClosureFast procedure
- Relief of symptoms after two days, with a noticeable improvement in one to two week
- Minimally invasive outpatient procedure
- Less pain and bruising than laser treatment
- Faster recovery than laser treatment
- Proven results with positive patient experience
- Rapid recovery — on average, patients resume normal activities within a few days
- Lasting results — the only radiofrequency energy procedure with published long-term clinical data demonstrating safety and efficacy, with a 91.9% closure rate at five years.4
Adverse events can include nerve injury, hematoma, phlebitis, thrombosis, and/or pulmonary embolism.
Type of therapy
Thermal shrinkage of the vein wall with radiofrequency energy or heatInpatient or outpatient procedure
Outpatient procedureOne- versus two-leg treatment
Typically, each leg will be treated in separate appointmentsNeedle sticks required
One needle stick for vein access. Typically, 5 to 10 needle sticks for anesthesia.Typical post-treatment recovery
Healing of vein access site, anesthetic needle stick sites, and also healing of ablated vein sectionCompression hose
Required for approximately one weekProcedure success rate
91.9% after five years4
ClosureFast procedure FAQ
Is the ClosureFast procedure painful?
Most patients report feeling little, if any, pain during the ClosureFast procedure.3 Your doctor will give you a local or regional anesthetic to numb the treatment area.
When can I return to normal activity?
Patients treated with the ClosureFast procedure may resume normal activity more quickly than patients who undergo surgical vein stripping or laser ablation. With the ClosureFast procedure, the average patient typically resumes normal activity within a few days.2 For a few weeks following the treatment, your vein specialist may recommend a regular walking regimen and suggest you refrain from strenuous activities (heavy lifting, for example) or prolonged periods of standing.
When will my symptoms improve?
Most patients report relief of symptoms after two days, with a noticeable improvement in one to two weeks.
Is there any scarring, bruising, or swelling after the procedure?
Most patients report limited to no scarring, bruising, or swelling following the ClosureFast procedure.3
How is the ClosureFast procedure different from endovenous lasers?
Both Closure Fast and lasers use thermal technology to deliver heat into the diseased vein, but they each use a different method of delivery. Despite their similarity in using heat, a 2009 study showed that the ClosureFast procedure is associated with lower rates of pain, bruising, and complications and a faster improvement in patients’ quality of life when compared to 980 nm laser ablation.4
How is the Closure Fast procedure different from vein stripping?
During vein stripping, incisions are made in the groin and calf, and a tool is threaded through the diseased vein to pull the vein out of the leg. With the ClosureFast procedure, only one small incision is made at the insertion site and the vein is then treated and left in place. ClosureFast is a minimally invasive approach that reduces the likelihood of pain and bruising, associated with vein stripping surgery.1
Is the ClosureFast procedure covered by insurance?
Many patients have access to the ClosureFast procedure through their insurance coverage plan. Insurance companies detail access to the ClosureFast procedure and other radiofrequency ablation procedures in coverage policies for varicose veins or chronic venous insufficiency. As with all healthcare procedures, you may also have some cost associated with receiving treatment, such as a copay or coinsurance. Please reach out to your insurance company to discuss your specific plan coverage and potential costs prior to seeking treatment
-
NC Sprinter PTCA BALLOON
NC Sprinter RX Noncompliant
NC Stormer over-the-wire noncompliant balloon dilatation catheter offers controlled compliance, high pressures, and comprehensive lengths.
Balloon Dilatation Catheter
OVERVIEW
The NC Sprinter™ RX noncompliant coronary balloon combines:
- Sprinter crossing technology
- High-pressure capability and controlled expansion1
ORDERING INFORMATION
BALLOON LENGTHS 6, 9, 12 MM
Balloon Diameter (mm)
Balloon Length (mm) 6 9 12 2.00 NCSP2006X NCSP2009X NCSP2012X 2.25 NCSP22506X — NCSP22512X 2.50 NCSP2506X NCSP2509X NCSP2512X 2.75 NCSP27506X NCSP27509X NCSP27512X 3.00 NCSP3006X NCSP3009X NCSP3012X 3.25 NCSP32506X NCSP32509X NCSP32512X 3.50 NCSP3506X NCSP3509X NCSP3512X 3.75 NCSP37506X NCSP37509X NCSP37512X 4.00 NCSP4006X NCSP4009X NCSP4012X 4.50 — — — 5.00 — — — BALLOON LENGTHS 15, 21, 27 MM
Balloon Diameter (mm)
Balloon Length (mm) 15 21 27 2.00 NCSP2015X NCSP2021X — 2.25 — NCSP22521X — 2.50 NCSP2515X NCSP2521X NCSP2527X 2.75 NCSP27515X NCSP27521X — 3.00 NCSP3015X NCSP3021X NCSP3027X 3.25 NCSP32515X NCSP32521X — 3.50 NCSP3515X NCSP3521X NCSP3527X 3.75 NCSP37515X NCSP37521X — 4.00 NCSP4015X NCSP4021X NCSP4027X 4.50 NCSP4515X NCSP4521X — 5.00 NCSP5015X — — -
RADIFOCUS INTRODUCER SHEATH
Radifocus™ Introducer II Standard Kit A
Introducer Sheath (FEMORAL)
Kit of vascular introducer with hemostatic valve with excellent blood tightness,
easy and non traumatic vessel insertion, patented valve design for a unique
features package.- Total Integrated Fit (TIF) tip tapering: tapering design at the tip of the sheath and dilator to facilitate smooth penetration
- Cross-cut hemostasis valve to avoid blood reflux and air aspiration
- Thin radiopaque sheath with anti-kinking sleeve for easy catheter handling
- Snap-on/click-off dilator lock prevents dilator back-out during insertion and allows one-hand unlocking
- Wide variety of kit variations providing all elements for quick vessel access: 4-11 Fr sheaths, 5-16 cm lengths, Surf lash needle
General specifications
Sheath length 10 cm Mini guidewire Plastic Straight and Angled
0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type; 0.035″ (0.89 mm) for all others
45 cmEntry needle Plastic IV Catheter – 18G x 2 ½” (1.2 x 64 mm),
except for 4 Fr with 45 cm straight mini guidewire: 20G x 2″ (0.9 x 51 mm)
2.5 ml syringe is includedGuidewire compatibility 0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type
0.035″ (0.89 mm) for all othersPackaging Tray A Kit content Sheath, dilator, plastic mini guidewire and plastic IV catheter (entry needle) Item specifications
Inner diameter Mini guidewire type 45 cm angled 45 cm straight 4 Fr RS+A40K10AQ RS+A40G10SQ 4 Fr RS*A40G10SQ RS*A40G05SQ 4 Fr RS*A40K10SQ RS*A40G07SQ 5 Fr RS*A50K10AQ RS*A50G07SQ 5 Fr RS+A50K10AQ RS+A50K10SQ 6 Fr RS+A60K10AQ RS+A60K10SQ 6 Fr RS*A60K10AQ RS*A60G07SQ 6 Fr — RS*A60G16SQZ 6 Fr — RS*A60K10SQ 6 Fr — RS+A50K10SQ 7 Fr — RS+A70K10SQ 7 Fr — RS*A70G07SQ 7 Fr — RS*A70K10SQ 8 Fr — RS+A80K10SQ 8 Fr — RS*A80K10SQ 9 Fr — RS*A90K10SQ 10 Fr — RS*A10K10SQ 11 Fr — RS*A11K10SQ A Kit includes: introducer sheath, dilator, mini Guide wire, entry venous catheter, 2.5 cc syringe
B Kit includes: introducer sheath, dilator, mini Guide wire
C Kit includes: introducer sheath, dilator
R Kit includes: introducer sheath, dilator, mini Guide wire, 18 G x 2 3/4” / 1.2 x 70 mm entry metallic needle
Other code numbers are available on special demand. For any further information, please contact your Terumo local representative
Units per box: 5 for kits in tray and 10 for kits in pouch.







Reviews
There are no reviews yet.