Heartrail® II – PTCA Guiding Catheter
Heartrail® II – PTCA Guiding Catheter
Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
General Specifications
| Shaft inner layer material | Polytetrafluoroethylene – PTFE |
|---|---|
| Braiding | High strength flat wire mesh pattern |
| Inner diameter | 5 Fr – 0.059″ (1.50 mm) 6 Fr – 0.071″ (1.80 mm) 7 Fr – 0.081″ (2.06 mm) |
| Usable length | 100 cm 120 cm – Heartrail 5 in 6 system |
| Sizes Available | Item Code |
|---|---|
| AL Short Tip 6F | TCO06GC-F6AL1SON |
| AL0.75/6F | TCO06GC-F6AL0G0N |
| AL1.0/6F | TCO06GC-F6AL010N |
| BL3.0/6F | TCO06GC-F6BL300N |
| BL3.5/6F | TCO06GC-F6BL350N |
| BL3.5/7F | TCO06GC-F7BL350N |
| BL4.0/6F | TCO06GC-F6BL400N |
| IKARI IL 3.5/5F | TCO06GC-F5IL350N |
| IKARI IL 3.5/6F | TCO06GC-F6IL350N |
| IKARI IL 4.0/6F | TCO06GC-F6IL400N |
| IKARI RIGHT 1.5/6F | TCO06GC-F6IR150N |
| Sizes Available | Item Code |
|---|---|
| JL3.5/5F | TCO06GC-F5JL350N |
| JL3.5/6F | TCO06GC-F6JL350N |
| JL4.0/6F | TCO06GC-F6JL400N |
| JR3.5/5F | TCO06GC-F5JR350N |
| JR3.5/6F | TCO06GC-F6JR350N |
| JR4.0/5F | TCO06GC-F5JR400N |
| JR4.0/6F | TCO06GC-F6JR400N |
| JR4.0/7F | TCO06GC-F7JR400N |
| MULTIPURPOSE 6F | TCO06GC-F6MP010N |
| TR4.0/6F | TCO06GC-F6TR400N |
Description
Optimize your challenging procedure
Heartrail™ II will improve your back-up force when using Ikari curves right and left during transradial interventions or through a 5Fr guiding catheter in 6Fr to increase backup support.
Characteristics
- Ikari curves right and left are developed to improve your back-up force during TRI via the right radial artery
- Tiger curves are designed to be used for both right and left coronary arteries
Feel the difference with the 5Fr guiding catheter in 6Fr
By inserting a 5 Fr (120 cm with flexible distal portion) into a 6 Fr guiding catheter:
- Provides the back-up support of a 7 Fr guiding catheter with a 6 Fr
- Minimizes puncture size
- Increases your back-up support for an excellent PTCA balloons crossing success rate1
General specifications
| Shaft inner layer material | Polytetrafluoroethylene – PTFE |
|---|---|
| Braiding | High strength flat wire mesh pattern |
| Inner diameter | 5 Fr – 0.059″ (1.50 mm) 6 Fr – 0.071″ (1.80 mm) 7 Fr – 0.081″ (2.06 mm) |
| Usable length | 100 cm 120 cm – Heartrail 5Fr straight, for 5Fr guiding catheter in 6Fr |
Item specifications
| Shape type | Shape code | 5 Fr | 6 Fr | 7 Fr |
|---|---|---|---|---|
| Amplatz Left | AL 1 | GC-K5AL010N | GC-K6AL010N | GC-K7AL010N |
| AL 2 | GC-K5AL020N | GC-K6AL020N | GC-K7AL020N | |
| AL 3 | GC-K5AL030N | GC-K6AL030N | GC-K7AL030N | |
| Amplatz Right | AR 1 | GC-K5AR010N | GC-K6AR010N | GC-K7AR010N |
| AR 2 | GC-K5AR020N | GC-K6AR020N | GC-K7AR020N | |
| Judkins Left | JL 3 | — | GC-K6JL300N | — |
| JL 3.5 | GC-K5JL350N | GC-K6JL350N | GC-K7JL350N | |
| JL 4 | GC-K5JL400N | GC-K6JL400N | GC-K7JL400N | |
| JL 4.5 | GC-K5JL450N | GC-K6JL450N | — | |
| JL 5 | GC-K5JL500N | GC-K6JL500N | GC-K7JL500N | |
| JL 6 | GC-K5JL600N | GC-K6JL600N | — | |
| Judkins Right | JR 3 | — | — | — |
| JR 3.5 | GC-K5JR350N | GC-K6JR300N | GC-K7JR350N | |
| JR 3.5 | — | GC-K6JR350N | — | |
| JR 4 | GC-K5JR400N | GC-K6JR400N | GC-K7JR400N | |
| JR 4.5 | GC-K5JR450N | — | — | |
| JR 5 | GC-K5JR500N | GC-K6JR500N | — | |
| JR 6 | — | GC-K6JR600N | — | |
| BackUp for left coronary |
BL 2.5 | — | — | — |
| BL 3 | GC-K5BL300N | GC-K6BL300N | GC-K7BL300N | |
| BL 3.5 | GC-K5BL350N | GC-K6BL350N | GC-K7BL350N | |
| BL 4 | GC-K5BL400N | GC-K6BL400N | GC-K7BL400N | |
| BL 4.5 | GC-K5BL450N | GC-K6BL450N | GC-K7BL450N | |
| BackUp for right coronary |
BR 3.5 | — | GC-K6BR350N | — |
| BR 4 | — | GC-K6BR400N | — | |
| IMA | IMA 1.0 | GC-K5IMA10N | GC-K6IMA10N | GC-K7IMA10N |
| Multipurpose | MPA-Large | GC-K5MP030N | GC-K6MP030N | GC-K7MP030N |
| Bypass |
BP-L | GC-K5BP010N | — | — |
| BP-R | GC-K5BP020N | GC-K6BP020N | — | |
| Ikari-Curve Left |
IL 3 | — | GC-K6IL300N | — |
| IL 3.5 | GC-K5IL350N | GC-K6IL350N | GC-K7IL350N | |
| IL 4 | GC-K5IL400N | GC-K6IL400N | GC-K7IL400N | |
| IL 4.5 | — | GC-K6IL450N | — | |
| Ikari-Curve Right |
IR 1 | — | GC-K6IR100N | — |
| IR 1.5 | GC-K5IR150N | GC-K6IR150N | GC-K7IR150N | |
| IR 2 | GC-K5IR200N | GC-K6IR200N | GC-K7IR200N | |
| Tiger | TIG 5 | GC-K5TR500N | — | — |
| — | — | — | — | GC-K7TR500N |
| — | — | — | GC-K6MP020N | — |
| — | — | — | GC-K6TR500N | — |
| — | — | — | GC-K6MP010N | — |
| — | — | — | GC-K6MP010N | — |
| 5Fr guiding catheter in 6Fr | Straight | GC-K5ST012NQ | — | — |
Heartrail® II – PTCA Guiding Catheter
Related products
-
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryurei™ has superior crossability1 thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1 results in enhanced trackability1 while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part, tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distal low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
Shaft diameter 1.9 Fr/0.64 mm Proximal • 2.5 Fr/0.84 mm Middle • 2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) • 2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) Usable length 145 cm Balloon markers # 1(Ø1.0 to Ø 1.5 mm) • 2(Ø2.0 to Ø4.0 mm) Nominal pressure 6 atm / 608 kPa Rated burst pressure Ø1.0 – 3.0 mm=14 atm(1419kPa) • Ø3.25 – 4.0 mm = 12 atm(1216 kPa) Guidewire compatibility Maximum diameter: 0.014″ / 0.36 mm Lesion entry profile 0.41 mm (Ø1.00 to Ø1.50 mm) • 0.43 mm (Ø2.00 to Ø4.00 mm) Coating Hydrophilic Item specifications
Balloon length / Product code
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH 1.25 mm DC-RR1205HH DC-RR1210HH DC-RR1215HH DC-RR1220HH 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1 Ryurei φ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ø 1.00 mm – Ø 1.50 mm.
** For Ryurei Ø 1.00mm – 5mm 2 Compared to Tazuna PTCA dilatation catheter
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.OPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitors -
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILS†
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.†
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.†
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ™Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export™ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export™ AP aspiration catheter without stylet.
-
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.







Reviews
There are no reviews yet.