CALL : 8447755671 , 77019 18238

Cart

Your Cart is Empty

Back To Shop

FX classix (FX60/FX80)

Homogeneous dialysate flow for better clearances

  • The pinnacle structure at both ends of the polypropylene housing together with the potting technology provides an even, radial flow of the dialysate around the individual fibers of the bundle
  • The undulation of the hollow fibers prevents dialysate channeling and, thus, enhances the performance of the dialyzer. The higher packing density of the fiber bundle together with the undulation of the hollow fibers enables a uniform dialysate flow within the whole cross-section of fiber bundle

Dialyzer weight

Dialyzer weight is a crucial factor not only in logistics but also in waste management. The housing of FX-class dialyzers is made of polypropylene. In comparison to the widely used polycarbonate it is much lighter with the result that FX-class dialyzers weigh around half as much as most dialyzers.
FX 60 classix 107g
FX CorDiax 60 107g

The benefits of INLINE steam sterilization

No chemical residuals No need for gamma sterilization – high energy ionizing radiation can degrade and alter the material chemistry. 
Low rinsing volumes Minimal preparation time – since dialyzers are clean on arrival, rinsing times prior to use are substantially reduced.  
Lower costs Lower rinsing volumes mean reduced preparation times and costs.

INLINE steam sterilisation

Purity enhanced — with steam

All FX-class dialyzers are sterilized by the unique INLINE steam sterilization process:  

  1. Both the blood and the dialysate compartment of the dialyzers are rinsed continuously with steam at a temperature of or above 121°C for more a minimum of 15 minutes. Rinsing with hot steam and without chemicals results in extremely low levels of residuals in the dialyzer
  2. The dialyzer is rinsed with sterile water  
  3. Every dialyzer is tested for fiber integrity using a bubble-point test  
  4. The dialyzers are dried with warm, sterile air  
  5. Finally, after drying the blood inlet and outlet ports are closed

Benefits of the INLINE steam sterilization process

  • Highly pure, sterile and pyrogen-free dialyzers without any potentially harmful residuals from sterilization
  • Biocompatibility of membranes remains unaffected from sterilization
  • Optimized use of resources due to low rinsing volumes: Only 500 mL is required
  • Minimized risk of blood leakages and fiber ruptures due to 100% fiber integrity testing
  • Dry dialyzers with minimized risk of contamination due to microbial growth

Performance data

FX classix High-Flux dialysers FX 50 classix FX 60 classix FX 80 classix FX 100 classix
Clearance (QB = 300 mL/min) Molecular weight (Dalton)
Cytochrome c 12,230 55 74 89 100
Inulin 5,200 72 95 113 122
Vitamin B12 1,355 137 162 185 201
Phosphate 132 204 225 244 253
Creatinine 113 224 243 259 264
Urea 60 253 266 279 280
Clearance (QB = 400 mL/min)
                                             
Cytochrome c 12,230 76 92 105
Inulin 5,200 99 119 129
Vitamin B12 1,355 175 202 222
Phosphate 132 252 279 291
Creatinine 113 277 300 309
Urea 60 312 334 336
  
Ultrafiltration coeff. (mL/h x mm Hg) 27 38 53 68
   
Sieving coefficients
Albumin 66,500 < 0.001
Myoglobin 17,053 0.1
β2-microglobulin 11,731 0.7
Inulin 5,200 1
In vitro performance: QD = 500 mL/min, QF = 0 mL/min, T = 37°C (ISO8637). Ultrafiltration coefficients: human blood, Hct 32 %, protein content 6 %.
Membrane material Helixone
Sterilisation method INLINE steam
Housing material Polypropylene
Potting compound Polyurethane
Units per box 24
   
Effective surface (m²)    1.0 1.4 1.8 2.2
K0A Urea 866 1,068 1,394 1,429
Priming volume (mL) 53 74 95 116
Article number F00002385 F00002386 F00002387 F00002388

FX classix