FIELDERĀ® FC
FIELDERĀ® FC
Greater control in challenging tortuous vessels/highly stenosed lesions. Polymer jacket provides advanced lubricity for superior torque.

| TIP LOAD | |
| TIP RADIOPACITY | 3 cm |
| COATING | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
| TIP SHAPE | Ā ![]() |
Ordering Information
| PRODUCT | CATALOG NO. | TIP SHAPE | LENGTH (CM) | DIAMETER (INCH(MM)) | RADIOPAQUE SEGMENT (CM) | SPRING COIL LENGTH (CM) | COATING |
|---|---|---|---|---|---|---|---|
| FIELDER FC 180cm, Straight | AGP140001 | Straight | 180 | 0.014 (0.36) | 3 | 11 | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
| FIELDER FC 180cm, J Shape | AGP140001J | J Shape | 180 | 0.014 (0.36) | 3 | 11 | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
| FIELDER FC 300cm, Straight | AGP140301 | Straight | 300 | 0.014 (0.36) | 3 | 11 | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
Indications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
Related products
-
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphora⢠noncompliant balloon
NC Euphora⢠noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora⢠noncompliant balloon dilatation catheter has what youāre looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it ā so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X Ā NCEUP32508X Ā NCEUP32512X 3.50 NCEUP3506X Ā NCEUP3508X Ā NCEUP3512X 3.75 NCEUP37506X Ā NCEUP37508X Ā NCEUP37512X 4.00 NCEUP4006X Ā NCEUP4008X Ā NCEUP4012X 4.50 Ā ā Ā NCEUP4508X Ā NCEUP4512X 5.00 Ā ā Ā NCEUP5008X Ā NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X ā 2.25 NCEUP22515X NCEUP22520X ā 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25 Ā NCEUP32515X Ā NCEUP32520X Ā NCEUP32527X 3.50 Ā NCEUP3515X Ā NCEUP3520X Ā NCEUP3527X 3.75 Ā NCEUP37515X Ā NCEUP37520X Ā NCEUP37527X 4.00 Ā NCEUP4015X Ā NCEUP4020X Ā NCEUP4027X 4.50 Ā NCEUP4515X Ā NCEUP4520X Ā ā 5.00 Ā NCEUP5015X ā Ā ā -
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technologyĀ where theĀ outside diameter is reduced by one French sizeĀ while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumoās proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumoās proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Associationās identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGYā¢: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.
-
ACT CARTRIDGE (HR-ACT)
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
SKU:402-03Weight:3.00 LBSAvailability:2-3 Business daysShipping:Calculated at checkoutQuantity:Product Description
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges,Ā High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50Ā
Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box 402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 ā 1.5 u/mL 50 per box 402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box 402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box -
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryurei⢠has superior crossability1Ā thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1Ā results in enhanced trackability1Ā while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part,Ā tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distalĀ low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
āShaft diameter ā1.9 Fr/0.64 mm Proximal ⢠2.5 Fr/0.84 mm Middle ⢠2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) ⢠2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) āUsable length ā145 cm āBalloon markers # ā1(Ć1.0 to Ć 1.5 mm) ⢠2(Ć2.0 to Ć4.0 mm) āNominal pressure ā6 atm / 608 kPa āRated burst pressure Ć1.0 – 3.0 mm=14 atm(1419kPa) ⢠Ć3.25 – 4.0 mm = 12 atm(1216Ā kPa) āGuidewire compatibility āMaximum diameter: 0.014″ / 0.36 mm āLesion entry profile ā0.41 mm (Ć1.00 to Ć1.50 mm) ⢠0.43 mm (Ć2.00 to Ć4.00 mm) āCoating āHydrophilic Item specifications
Balloon length / Product codeāā ā ā ā ā ā
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH ā1.25 mm āDC-RR1205HH āāDC-RR1210HH āāDC-RR1215HH āāDC-RR1220HH ā ā 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1Ā Ryurei Ļ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ć 1.00 mm ā Ć 1.50 mm.
** For Ryurei Ć 1.00mm ā 5mm ā2Ā Compared to Tazuna PTCA dilatation catheter





Ā 




Reviews