ELIMINATE™ – ASPIRATION CATHETER
Description
A fast and simple solution for effective thrombus aspiration
Eliminate is an innovative aspiration catheter designed to offer a balance between crossing performance, kink resistance and thrombus-aspiration capability.
Aspiration catheter. The deliverable solution for thrombus removal. Guide catheter compatibility. EliminateTM. 6Fr. (I.D. ≥ 0.70 inch / 1.78 mm).
Eliminate™ is an aspiration catheter intended for removing fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature.
Initial experience with a mechanical aspiration catheter for thrombus removal during … Catalog. Number. Description. Distal OD (in). Total Length.
Characteristics
Dedicated tip design with radiopaque marker
- Excellent crossability1 while providing atraumatic and effective aspiration
- Ensures reliable fluoroscopic visibility
Braided shaft with hydrophilic coating and pre-loaded stiffening stylet2
- Excellent pushability and kink resistance1
- Easy navigation through tortuous anatomies
Large aspiration lumen
- Constant, high-performance aspiration throughout the procedure
- Choice of three sizes (6 Fr, 7 Fr and 8 Fr guide catheter compatibility) for different coronary and peripheral applications
![](https://www.terumo-europe.com/Product%20Images/eliminate_technical_drawing_2.jpg)
Guide Catheter Compatibility
![](https://www.terumo-europe.com/Product%20Images/eliminate_technical_drawing.jpg)
General specifications
Usable length | 140 cm |
---|---|
Distal tip hole length | 4 mm for 6 and 7 Fr, 7 mm for 8 Fr |
Rapid exchange segment | 23 cm |
Radiopaque marker | 1 mm located at 4 mm from the tip |
Positioning marker | 10 cm = single white mark located at 90 cm from distal tip |
Guidewire compatibility | Maximum diameter 0.014″ (0.36 mm) |
Coating | Hydrophilic |
Item specifications
Guide catheter compatibility | Guide sheath compatibility | Item reference | |
---|---|---|---|
6 Fr | I.D. ≥ 0.070″ / 1.78 mm | — | EG1602 |
7 Fr | I.D. ≥ 0.080″ / 2.03 mm | — | EG1652 |
8 Fr | I.D. ≥ 0.086″ / 2.18 mm | 6 Fr | EG1401 |
Please quote above item reference codes when placing an order.
References
1 Onuma et al.; Eur Heart J. 2013 Apr;34(14):1050-60. doi: 10.1093/eurheartj/ehs456. Epub 2013 Feb 8.
2 Only the 6 Fr and 7 Fr options are pre-loaded.
ELIMINATE™ – ASPIRATION CATHETER
Related products
-
PTFE GUIDEWIRE EMERILD
Rosen Heavy Duty and Amplatz Super Stiff
PTFE-Coated EMERALDTM Guidewires*EMERALD Diagnostic Guidewire is built with performance, endurance and safety. Built to minimize the likelihood of stretching or fracturing.
Super Stiff EMERALD™ Guidewires. PTFE pre-coated guidewire. Pre-coated. Cordis EMERALD™. Diagnostic Guidewires … Please consult your Cordis Catalogue.
Product Description · Enhanced maneuverability · Ability to finger straighten · Proprietary PTFE coating process · Available in multiple shapes and sizes.
Product Description
Intended for percutaneous entry and guidance of catheters, the Cordis EMERALD® Diagnostic Guidewire complements our diagnostic catheter and catheter sheath introducer lines. Performance, endurance and safety are built into each EMERALD™ Guidewire with solid tensile strength to minimize the likelihood of stretching or fracturing.• For percutaneous entry and
guidance of angiographic catheters
• Pre-coated PTFE
• 5 units per package• Atraumatic end
• For percutaneous entry and high
support guidance of angiographic
catheters
• 5 units per package.Established as a Partnership firm in the year 2021 at Shahdara (Delhi, India), we “B & A Enterprises” are a leading Wholesale Trader of a wide range of Guide Wire, Asahi Guide Wire, Introducer Needles, etc. B&A is an Quality and Customer centric organization which believes in excellence in bridging gap between need and medical products. At B&A we deliver outstanding products across 5 key medical products domain: Cardiology, Nephrology, Urology, Neurology and Radiology. Our medical products bridge the gap between the constant need for quality and the increasing demand for savings. Our product portfolio is a comprehensive offering of clinician-preference, cost-efficient products, and physician-preferred items with low clinical differentiation, helping providers improve the bottom line while delivering high-quality care. Because we work from the acute channel to the home, we’re uniquely positioned to stay ahead, finding product efficiencies that move care forward.
-
PTCA BALLOON TRACK
TREK™ Coronary Dilatation Catheter’s unique design provides smooth transitions from hub to tip.
- Transition less tip
- Flexible distal shaft
- Multi-layer CrossFlex²* balloon and Slim Seal** technology.
TECHNICAL INFORMATION
TREK™ & MINI TREK™ CORONARY DILATATION CATHETERS NOMINAL PRESSURE (NP) 8 atm RATED BURST PRESSURE (RBP) 14 atm TIP ENTRY PROFILE 0.017 in (3.00 mm Ø) TIP CROSSING PROFILE 0.021 in average (3.00 mm Ø)
0.023 in maximumFOLDED BALLOON CROSSING PROFILE 0.032 in average (3.00 mm Ø)
0.036 in maximum (3.00 mm Ø)REFOLDED BALLOON CROSSING PROFILE 0.056 in maximum (3.00 mm Ø) RX NOTCH DIAMETER (FOR RX PLATFORM) 2.5 French average (3.00 mm Ø)
2.7 French maximum (all Ø)TIP LENGTH <3 mm BALLOON MATERIAL Pebax†, semi-compliant MARKER MATERIAL Flexible Tungsten/Pebax‡ CATHETER LENGTH 145 cm BALLOON COATING Hydrophilic MINIMUM GUIDE CATHETER 5 French (1.20 mm – 4.00 mm Ø)
6 French (4.50 mm & 5.00 mm Ø)MAXIMUM GUIDE WIRE COMPATIBILITY 0.014 in LATEX FREE Yes Caution
CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE. OBSERVE ALL WARNINGS AND PRECAUTIONS NOTED THROUGHOUT THESE INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN COMPLICATIONS.
Indications
Applies to TREK™ RX & OTW 2.25 mm – 5.00 mm sizes only:
The TREK™ RX & OTW Coronary Dilatation Catheters are indicated for:- Balloon dilatation of the stenotic portion of a coronary artery or bypass graft stenosis, for the purpose of improving myocardial perfusion
- Balloon dilatation of a coronary artery occlusion, for the purpose of restoring coronary flow in patients with ST-segment elevation myocardial infarction
- Balloon dilatation of a stent after implantation
-
OPTITORQUE TIG CATHETER
OPTITORQUE® Coronary Diagnostic Catheter
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitorsPRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.1
1.DOF
a. when compared to leading competitorsRADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time2
1. DOF Reference
a. when compared to leading competitors
2. Ikari articleUNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitorsPRODUCT CODES
OPTITORQUE Radial-Specific Shapes
Shape Category Product Code 5 Fr / 1.70 mm
Product Code 6 Fr / 2.00 mm
Shape Name Length (cm) Side Holes Tiger 40-5011 40-6011 Radial TIG 4.0 100 1 40-5013 40-6013 Radial TIG 4.0 110 1 40-5012 40-6012 Radial TIG 4.5 100 1 40-5014 40-6014 Radial TIG 4.5 110 1 Jacky 40-5021 40-6021 Jacky Radial (Curve Size 3.5) 100 2 40-5023 40-6023 Jacky Radial (Curve Size 3.5) 110 2 40-5022 40-6022 Sarah Radial (Curve Size 4.0) 100 2 40-5024 40-6024 Sarah Radial (Curve Size 4.0) 110 2 OPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 -
AVANTI®+ INTRODUCER SHEATH
Product Description
Sheath introducers (Cordis) central lines are large-bore catheters (6-8.5 Fr) commonly placed in the ED for rapid infusion of large volumes of crystalloid or colloid, insertion of transvenous pacemakers, and administration of medications that needing reliable central access.
For use in arterial and venous procedures requiring percutaneous introduction of Intravascular devices.
The Cordis AVANTI+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a SLIX Valve, the AVANTI+ Introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as:
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates greater procedural flexibility. It stays in place better and allows more patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer for improved bendability and support. It is also less prone to kinking, cost-effective and reliable.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and may help lessen damage upon entry.
What size is a Cordis? A Cordis/AVANTI comes in many sizes. For the sake of rapid infusion, the sizes go from 8-11 french. There are two lengths of the large-bore cannula: 11cm and 23cm.
Introducer sheaths are used when there is the need for a larger catheter, such as for rapid volume administration or for the insertion of a pulmonary artery catheter.
The Correct Way to Pull a Sheath
- Take your index, middle and sometimes your ring finger, and place them slightly above the sheath to feel the patient’s pulse.
- Slowly remove the sheath in a sterile manner, holding occlusive pressure to avoid bleeding.
Our product range includes a wide range of Avanti transradial kit, cordis vista brite tip guiding catheters, emerald guidewire 150cm, guiding catheter 5f xb 3.5lbt, femoral sheath and empira ptca balloons cordis.
We are one of the leading Trader, Importer and Exporter of this highly commendable and diverse range of Aspiration Catheter, Transseptal Needle, Control Coronary Syringes, Introducer Sets etc.
Reviews
There are no reviews yet.