DXTERITY DIAGNOSTIC CATHETER
DxTerityâ„¢
Diagnostic CatheterÂ
PRODUCT DETAILSâ€
DxTerity Catheters Feature:
- Unique, ergonomic, winged hubs for easy manipulation
- Solid shaft construction for efficient torque and excellent overall catheter performance
- Double-braid wire for enhanced torque, strength, and kink resistance
- InSlide™ polymer additive for superior lubricity and enhanced deliverability1
- Soft, atraumatic, radiopaque tip for excellent visibility
- Large lumen for high flow of contrast media to increase visualization2Â
Features and Benefits
Enhanced deliverability:
§ InSlide™ polymer additive for superior lubricity to
reduce friction and enhance deliverability2
Precise manipulation:
§ Unique, ergonomic, winged hub design for easy
manipulation
§ Double-braid wire applied from hub to tip enhances
strength, torque and kink resistance
Excellent image quality:
§ Soft, atraumatic radiopaque tip allows for increased
visibility
§ Large lumen enables high flow of contrast media to
increase visualisation
Broad catheter portfolio:
§ Optimised for both radial and femoral procedures
§ Wide range of shapes and sizes
§ Includes expanded offerings of long (125 cm) lengths
Market-leading technology improves
performance where it matters:
§ Superior torque and lubricity for precise
manipulation and enhanced deliverability3
§ Optimised for both radial and femoral procedures4
§ Wide range of shapes and sizes
Ordering Information
Curve Style
Curve
Size
Length
(cm) Product Code Sideholes
Judkins Left JL 3.5 100 DXT5JL35 0
JL 4.0 100 DXT5JL40 0
JL 4.0 125 DXT5JL40X 0
JL 4.5 100 DXT5JL45 0
JL 4.5 125 DXT5JL45X 0
JL 5.0 100 DXT5JL50 0
JL 5.0 125 DXT5JL50X 0
JL 6.0 100 DXT5JL60 0
Judkins Right JR 3.5 100 DXT5JR35 0
JR 3.5 125 DXT5JR35X 0
JR 4.0 100 DXT5JR40 0
JR 4.0 125 DXT5JR40X 0
JR 4.0 ST 100 DXT5JR4ST 0
JR 4.0 MOD 100 DXT5JR4M 0
JR 5.0 100 DXT5JR50 0
JR 5.0 125 DXT5JR50X 0
JR 6.0 100 DXT5JR60 0
Amplatz Left AL 1.0 100 DXT5AL10 0
AL 2.0 100 DXT5AL20 0
AL 3.0 100 DXT5AL30 0
Amplatz Right AR 1.0 100 DXT5AR10 0
AR 2.0 100 DXT5AR20 0
AR MOD 100 DXT5ARM 0
Multipurpose MPA 100 DXT5MPA 0
MPA 110 DXT5MPAA 0
MPA 100 DXT5MPASH 2
MPA 110 DXT5MPASHA 2
MPB 100 DXT5MPB 0
MPB 110 DXT5MPBA 0
MPB 100 DXT5MPBSH 2
MPB 110 DXT5MPBSHA 2
Specialty NOTO 100 DXT5NOTO 0
3DRC 100 DXT53DRC 0
RCB 100 DXT5RCB 0
LCB 100 DXT5LCB 0
IMA 100 DXT5IMA 0
Pigtails PIG STR 110 DXT5PIGSTA 6
PIG STR 125 DXT5PIGSTX 6
PIG 145 110 DXT5PIG45A 6
PIG 155 110 DXT5PIG55A 6
DXTERITY DIAGNOSTIC CATHETER
Related products
-
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technology where the outside diameter is reduced by one French size while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumo’s proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumo’s proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Association’s identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGYâ„¢: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.
-
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.
-
Launcher- 7f Guiding Catheter’s
EBU@ (Extra Backup)
LA7EBU30 (EBU 3.0)
LA7EBU35 (EBU 3.5)
LA7EBU375 (EBU 3.75)
LA7EBU40 (EBU 4.0)
LA7EBU45 (EBU 4.5)
LA7EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA7JL30 (JL 3.0)
LA7JL35 (JL 3.5)
LA7JL40 (JL 4.0)
LA7JL45 (JL 4.5)
LA7JL50 (JL 5.0)
LA7JL60 (JL 6.0)
JR@ (Judkin Right )
LA7JR30 (JR 3.0)
LA7JR35 (JR 3.5)
LA7JR40 (JR 4.0)
LA7JR45 (JR 4.5)
LA7JR50 (JR 5.0)
LA7JR60 (JR 6.0)
AL@ (Amplatz Left )
LA7AL75 (AL .75)
LA7AL10 (AL 1.0)
LA7AL15 (AL 1.5)
LA7AL20 (AL 2.0)
LA7AL25 (AL 2.5)
LA7AL30 (AL 3.0)
LA7AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA7SAL75 (SAL . 75)
LA7SAL10 (SAL 1.0)
LA7SAL15 (SAL 1.5)
LA7SAL20 (SAL 2.0)
LA7SAL25 (SAL 2.5)
LA7SAL30 (SAL 3.0)
LA7SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA7AR10 (AR 1.0)
LA7AR20 (AR 2.0)
LA7ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA7ECR35 (ECR 3.5)
LA7ECR40 (ECR 4.0)
LA7ECR45 (ECR 4.5)
LA7RBU35 (RBU 3.5)
LA7RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA7SCR35 (SCR 3.5)
LA7SCR40 (SCR 4.0)
LA7SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA7SAR10 (SAR 1.0)
LA7SAR20 (SAR 2.0)
Multipurpose@
LA7MB1 (MB 1)
LA7MB2 (MB 2)
LA7HSREL (Hockey Stick)
LA7HSI (Hockey I)
LA7HSII (Hockey II)
LA7HSIII (Hockey III)
Bypass Crafts@
LA7LCB (LCB)
LA7RCB (RCB)
LA7RCB (RCB III)
LA7RCB (RCBÂ 90cm)
LA7IMA (IMA)
LA7IMA (IMAÂ 90cm)
-
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryureiâ„¢ has superior crossability1Â thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1Â results in enhanced trackability1Â while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part, tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distal low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
​Shaft diameter ​1.9 Fr/0.64 mm Proximal • 2.5 Fr/0.84 mm Middle • 2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) • 2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) ​Usable length ​145 cm ​Balloon markers # ​1(Ø1.0 to Ø 1.5 mm) • 2(Ø2.0 to Ø4.0 mm) ​Nominal pressure ​6 atm / 608 kPa ​Rated burst pressure Ø1.0 – 3.0 mm=14 atm(1419kPa) • Ø3.25 – 4.0 mm = 12 atm(1216 kPa) ​Guidewire compatibility ​Maximum diameter: 0.014″ / 0.36 mm ​Lesion entry profile ​0.41 mm (Ø1.00 to Ø1.50 mm) • 0.43 mm (Ø2.00 to Ø4.00 mm) ​Coating ​Hydrophilic Item specifications
Balloon length / Product code​​ ​ ​ ​ ​ ​
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH ​1.25 mm ​DC-RR1205HH ​​DC-RR1210HH ​​DC-RR1215HH ​​DC-RR1220HH ​ ​ 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1 Ryurei φ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ø 1.00 mm – Ø 1.50 mm.
** For Ryurei Ø 1.00mm – 5mm ​2 Compared to Tazuna PTCA dilatation catheter









Reviews
There are no reviews yet.