CORDIS Transradial Kit
Avanti Transradial Kit
Product Description
Cordis 504626Z 6Frx23cm Cordis AVANTI+ Transradial Kit includes: AVANTI+ Sheath Introducer 6Frx23cm, w vessel dilator 31.5cm, mini-guidewire.021″x70cm, &  21G needle 504-626Z Bx of 5
The Cordis 504626Z AVANTI + Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates greater procedural flexibility. It stays in place better and allows more patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer for improved bendability and support. It is also less prone to kinking, cost-effective and reliable.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and may help lessen damage upon entry.
Related products
-
RADIFOCUS REDIAL SHEATH
Providing you the best range of Terumo Radifocus Radial Introducer Sheath and Cordis Femoral Introducer Sheath with effective & timely delivery.
The radial artery access sheath is used to gain arterial access and facilitate the insertion of catheters or other equipment for diagnostic and vascular interventions.
- The Cordis AVANTI®+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI®+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates procedural flexibility. It stays in place and allows patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and helps to minimize damage upon entry.
As part of the circulatory system, the radial artery supplies blood from the heart to the forearm.
Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.
-
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinterâ„¢ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinterâ„¢ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Â Selective Dura-Trac coating
- Â 2.5 mm tip
- Â FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip
-
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS
-
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technology where the outside diameter is reduced by one French size while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumo’s proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumo’s proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Association’s identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGYâ„¢: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.









Quiernera –
Mean testicular volume in these patients rose from 8 priligy walgreens
Quiernera –
The estrogen analog tamoxifen TAM, used for adjuvant therapy of breast cancer, induces endometrial and uterine tumors in breast cancer patients priligy for sale
can i buy generic cytotec pills –
Jocelyn cNQpCieRYNCHcXfJxEU 6 19 2022 where can i get cytotec without dr prescription Chuck rxNCgXmsxrBLuTTkZj 6 17 2022