CARDIOPLEGIA CANNULA
XCELL CARDIOPLEGIA CANNULA
Aortic Root Cannulas are intended for safe and
easy use in the infusion of cardioplegia and aortic root bubble venting. They feature radiopaque
tips attached to their PVC bodies. Additional
features available with these cannulas include
aortic root pressure monitoring and left heart
venting. All cannulas are supplied with a stainless steel introducer needle.
CARDIOPLEGIA CANNULA
Aortic Root Cannula
without Vent Line
Order No. Model Description
ARC-S-15 Adult
Without vent line, 15 GA,
fixation flange, female luer
connector
ARC-S-16 Pediatric
Without vent line, 16 GA,
fixation flange, female luer
connector
AORTIC ROOT CANNULA: The product is intended for use during cardiopulmonary bypass for delivering cardioplegia solutions and venting of the
left heart for up to six hours. The cannula may be used to aspirate air from
the aorta at the conclusion of the bypass procedure.
FEATURES
• Medical grade PVC material for the body.
• The special stainless steel treatment makes
the needle rigid and tenacious.
• Molded tip resists kinking.
Related products
-
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.
-
PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- ​Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
Shaft diameter 1.9 Fr / 0.64Â mm Proximal
2.5 Fr / 0.84 mm Mid
2.6 Fr / 0.86 mm DistalUsable length 145 cm Balloon markers 2 Nominal pressure 12 atm / 1216 kPa Rated burst pressure 22 atm / 2229 kPa (2.0 mm to 4.0 mm)
20 atm / 2026 kPa (4.5 and 5.0 mm)Guidewire compatibility Maximum diameter 0.014″ / 0.36 mm Lesion entry profile 0.43 mm Coating Hydrophilic Item specifications
Ordering Information
Balloon
diameter
(mm) ​Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​ 6 8 12 15 20 25 30 2.00 DC-RM2006HSW DC-RM2008HSW DC-RM2012HHW DC-RM2015HHW DC-RM2020HHW — — 2.25 DC-RM2206HSW DC-RM2208HSW DC-RM2212HHW DC-RM2215HHW DC-RM2220HHW — — 2.50 DC-RM2506HSW DC-RM2508HSW DC-RM2512HHW DC-RM2515HHW DC-RM2520HHW DC-RM2525HHW DC-RM2530HHW 2.75 DC-RM2706HSW DC-RM2708HSW DC-RM2712HHW DC-RM2715HHW DC-RM2720HHW — — 3.00 DC-RM3006HSW DC-RM3008HSW DC-RM3012HHW DC-RM3015HHW DC-RM3020HHW DC-RM3025HHW DC-RM3030HHW 3.25 DC-RM3206HSW DC-RM3208HSW DC-RM3212HHW DC-RM3215HHW DC-RM3220HHW — — 3.50 DC-RM3506HSW DC-RM3508HSW DC-RM3512HHW DC-RM3515HHW DC-RM3520HHW DC-RM3525HHW DC-RM3530HHW 3.75 DC-RM3706HSW DC-RM3708HSW DC-RM3712HHW DC-RM3715HHW DC-RM3720HHW — — 4.00 DC-RM4006HSW DC-RM4008HSW DC-RM4012HHW DC-RM4015HHW DC-RM4020HHW — — 4.50 DC-RM4506HSW DC-RM4508HSW DC-RM4512HSW DC-RM4515HSW — — — 5.00 DC-RM5006HSW DC-RM5008HSW DC-RM5012HSW DC-RM5015HSW — — — Please quote above item reference codes when placing an order.
Balloon Compliance
Balloon
diameter
(mm) ​Pressure (atm) ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2.00 1.58 1.65 1.72 1.79 1.84 1.88 1.92 1.95 1.98 2.00* 2.01 2.03 2.04 2.05 2.06 2.08 2.09 2.10 2.12 2.13** 2.14 2.15 2.17 2.25 1.96 2.01 2.06 2.11 2.14 2.16 2.19 2.21 2.23 2.25* 2.26 2.28 2.29 2.31 2.32 2.34 2.35 2.36 2.38 2.39** 2.41 2.42 2.44 2.50 2.19 2.24 2.30 2.36 2.38 2.41 2.44 2.46 2.48 2.50* 2.52 2.53 2.55 2.56 2.58 2.60 2.61 2.63 2.64 2.66** 2.68 2.69 2.71 2.75 2.43 2.48 2.53 2.59 2.62 2.65 2.67 2.70 2.73 2.75* 2.77 2.79 2.80 2.82 2.84 2.86 2.87 2.89 2.91 2.93** 2.94 2.96 2.98 3.00 2.65 2.71 2.76 2.82 2.85 2.89 2.92 2.95 2.97 3.00* 3.02 3.04 3.06 3.08 3.10 3.11 3.13 3.15 3.17 3.19** 3.21 3.23 3.25 3.25 2.89 2.95 3.01 3.07 3.10 3.14 3.17 3.20 3.22 3.25* 3.27 3.29 3.31 3.33 3.35 3.37 3.39 3.42 3.44 3.46** 3.47 3.48 3.51 3.50 3.13 3.19 3.26 3.32 3.35 3.39 3.42 3.45 3.47 3.50* 3.52 3.54 3.57 3.59 3.61 3.63 3.65 3.68 3.70 3.72** 3.74 3.74 3.76 3.75 3.37 3.44 3.50 3.56 3.60 3.63 3.66 3.69 3.72 3.75* 3.77 3.80 3.82 3.84 3.86 3.88 3.90 3.92 3.94 3.96** 3.98 3.99 4.01 4.00 3.58 3.65 3.72 3.79 3.83 3.87 3.90 3.94 3.97 4.00* 4.03 4.05 4.07 4.09 4.11 4.13 4.15 4.17 4.19 4.21** 4.23 4.26 4.28 4.50 4.02 4.10 4.19 4.28 4.32 4.37 4.40 4.44 4.47 4.50* 4.53 4.56 4.59 4.63 4.66 4.68 4.71 4.75** 4.78 4.81 4.84 4.87 4.91 5.00 4.52 4.59 4.67 4.75 4.80 4.85 4.89 4.93 4.96 5.00* 5.03 5.07 5.10 5.13 5.16 5.19 5.22 5.26** 5.29 5.32 5.35 5.38 5.41 * Nominal pressure
** Rated burst pressureReferences
​​1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Ordering Information. Balloon diameter (mm) ​, Balloon length (mm) / Item references ​ ​ ​ ​ ​ ​.Balloon markers: 2Usable length: 145 cmCoating: HydrophilicLesion entry profile: 0.43 mmStraight-Single Latex Plastic Terumo Accuforce Balloon Catheter, Size: Medium ; Application, Hospital ; Brand, Terumo ; Material, Latex ; Inner Diameter, 36mm. -
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS
-
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryureiâ„¢ has superior crossability1Â thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1Â results in enhanced trackability1Â while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part, tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distal low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
​Shaft diameter ​1.9 Fr/0.64 mm Proximal • 2.5 Fr/0.84 mm Middle • 2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) • 2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) ​Usable length ​145 cm ​Balloon markers # ​1(Ø1.0 to Ø 1.5 mm) • 2(Ø2.0 to Ø4.0 mm) ​Nominal pressure ​6 atm / 608 kPa ​Rated burst pressure Ø1.0 – 3.0 mm=14 atm(1419kPa) • Ø3.25 – 4.0 mm = 12 atm(1216 kPa) ​Guidewire compatibility ​Maximum diameter: 0.014″ / 0.36 mm ​Lesion entry profile ​0.41 mm (Ø1.00 to Ø1.50 mm) • 0.43 mm (Ø2.00 to Ø4.00 mm) ​Coating ​Hydrophilic Item specifications
Balloon length / Product code​​ ​ ​ ​ ​ ​
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH ​1.25 mm ​DC-RR1205HH ​​DC-RR1210HH ​​DC-RR1215HH ​​DC-RR1220HH ​ ​ 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1 Ryurei φ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ø 1.00 mm – Ø 1.50 mm.
** For Ryurei Ø 1.00mm – 5mm ​2 Compared to Tazuna PTCA dilatation catheter