CAPIOX® RX OXYGENATOR
Description
Oxygenator
Balanced Performance
- Low priming volume, high gas exchange and low pressure drop are optimally balanced for superb performance.
- Hollow fibers manufactured exclusively by Terumo using a patented technology with total quality management from raw materials to finished product.
- Woven fiber bundle ensures consistent and high-performance gas exchange.
- Choice of blood outlet port configurations for easy access and increased circuit flexibility.
- Top-to-bottom blood flow path and air purge line provide excellent air removal capability.
- No DEHP used in PVC tubing.
Hardshell Reservoir
Full Featured
- Elongated shape provides a stable blood flow path and enhanced visibility at all levels from all angles.
- Rotating venous inlet improves set-up flexibility.
- No DEHP used in PVC tubing.
- Connecting mount increases flexibility in circuit set-up and oxygenator rotation.
- Funnel-shaped cardiotomy filter improves breakthrough and residual volumes.
- Positive pressure relief value for additional safety.
Characteristics
- Terumo’s exclusive hollow fiber
- High flow with very low priming volume
- Superior O2 transfer performance
- Outstandingly low pressure drop
General specifications
Oxygenator
| Oxygenator | RX15 R30 reservoir | RX15 R40 reservoir | RX25 |
|---|---|---|---|
| Housing material | Polycarbonate | ||
| Fiber material | Microporous polypropylene | ||
| Heat exchanger material | Stainless steel | ||
| Fibers: Approx. surface area | 1.5 m² | 1.5 m² | 2.5 m² |
| Heat exchanger: Approx. surface area | 0.14 m² | 0.14 m² | 0.2 m² |
| Blood flow range | 0.5 – 4.0 L/min | 0.5 – 5.0 L/min | 0.5 – 7.0 L/min |
| Priming Volume (static) | 135 mL | 135 mL | 250 mL |
| Blood inlet port (from pump) | 3/8″ (9.5 mm) | ||
| Blood outlet port | 3/8″ (9.5 mm) | ||
| Cardioplegia port | 1/4″ (6.4 mm) | ||
| Gas inlet port | 1/4″ (6.4 mm) | ||
| Gas outlet port | 1/4″ (6.4 mm) | ||
| Water ports | 1/2″ (12.7 mm) Hansen quick connect fittings | ||
| Maximum pressure Blood inlet | 133 kPa (1.000 mmHg) | ||
| Maximum pressure Water inlet | 196 kPa (2 kgf/cm²)(28.5 psi) | ||
Hardshell reservoir
| Hardshell Reservoir | RX15 R30 reservoir | RX15 R40 reservoir | RX25 |
|---|---|---|---|
| Housing material | Polycarbonate | ||
| Venous filter materials | Polyester screen type | ||
| Cardiotomy filter material | Polyester depth type | ||
| Defoamer material | Polyurethane foam | ||
| Blood flow range: Venous | 0.5 – 4.0 L/min | 0.5 – 5.0 L/min | 0.5 – 7.0 L/min |
| Blood flow range: Cardiotomy inlet | 4.0 L/min | 5.0 L/min | 5.0 L/min |
| Blood flow range: Combined flow | 4.0 L/min | 5.0 L/min | 7.0 L/min |
| Blood storage capacity | 3.000 mL | 4.000 mL | 4.000 mL |
| Minimum operating volume | 70 mL | 200 mL | 200 mL |
| Venous blood inlet port (rotatable) > when 1/4″ adaptor is attached |
3/8″ (9.5 mm); 1/4″ (6.4 mm) |
1/2″ (12.7 mm) | |
| Blood outlet port (to pump) > when 1/4″ adaptor is attached |
3/8″ (9.5 mm); 1/4″ (6.4 mm) |
3/8″ (9.5 mm) | |
| Suction ports (rotatable) | Six: 1/4″ (6.4 mm) | ||
| Vertical port (to CR filter) | 3/8″ (9.5 mm) | ||
| Quick prime port | 1/4″ (6.4 mm) | ||
| Vent port | 1/4″ (6.4 mm) | ||
| Auxiliary port | 1/4″ – 3/8″ (6.4 mm – 9.5 mm) | ||
| Luer ports | Three filtered luer locks to cardiotomy filter, one non-filtered luer lock, two luer locks on venous inlet | ||
| Maximum sustainable negative pressure in reservoir | -20.0 kPa (-150 mmHg) | ||
Xcoating™ Surface Coating, Terumo Corporation’s biocompatible amphiphilic polymer surface coating, is a standard feature on the CAPIOX® RX Oxygenators.
Item specifications
Choose the blood outlet port configuration that best suits your circuit.
| West outlet port
Oxy inlet on right when outlet is
facing away from user
|
East outlet port
Oxy inlet on left when outlet is
facing away from user
|
Related products
-
Everest30 INFLATION DEVICE
Everest 30
Disposable Inflation Device
OVERVIEW
Easy-to-use Rapid Inflation/Deflation Device
A simple solution for coronary balloon inflation. The Everest disposable inflation device features a quick trigger release and ergonomic pistol grip for ease of use. Plus, it’s available in your choice of 20 atm or 30 atm pressure gauge, and as a standalone or in a packaged kit.
PRODUCT DETAILS
The Everest Device Features:
- Quick trigger release so you can release pressure immediately, even at higher pressures
- Sure-grip torque knob with a ridged design for “no slip” torque control and precise pressure adjustment
- Unique ergonomic pistol grip with centered trigger that fits comfortably in either hand
- Luminescent dial face that provides accurate readability in normal and low-light conditions
EVEREST DISPOSABLE INFLATION DEVICE ORDERING INFORMATION
Disposable Inflation Device@ AC3200
Survival Kit Inflation Device@ AC305P
Everest20 inflation device
and 3-way stopcockAC2200 1 each Everest30 inflation device
and 3-way stopcockAC3200 1 each Everest20 Survival Kit: - Everest20 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC2205P 1 each Everest30 Survival Kit: - Everest30 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC3205P 1 each ACCESSORIES ORDERING INFORMATION
Metal guidewire insertion tool 006073 5 each Torque handle AC4006 5 each Piton™ Y-Adapter with metal guidewire insertion tool AC4001M 5 each Piton™ Tri-Adapter with metal guidewire insertion tool AC4002M 5 each Piton™ Y-Adapter with metal guidewire insertion tool and torque handle AC4003M 5 each -
RESOLUTE INTEGRITY STENT
Resolute Onyx DES
for coronary artery disease
Resolute Onyx™ is a drug-eluting stent (DES) that’s different by design, optimised for complex PCI, and proven safe and effective in real-world, high bleeding risk patients on 1-month dual antiplatelet therapy (DAPT).1
Resolute Onyx DES is different by design to address your DES needs and a wide range of patient anatomies. It features:
- Best-in-class deliver ability
- Enhanced visibility with thinner struts
- Smooth side branch access
- Fast healing
- The broadest diameter range
Best-in-class deliverability
Single-wire design
Resolute Onyx DES is made from a single wire, which gives it a fluid range of motion and provides the flexibility needed for best-in-class deliverability.2

Sinusoid-formed wire

Helical wrap

Laser-fused
Competitive comparison
Resolute Onyx DES is more deliverable than laser-cut SYNERGY™* XD and XIENCE Skypoint™*, which are stiffer.
Deliverability comparison — 3.0 mm DES2
(Lower is better)

Enhanced visibility with thinner struts
Platinum-iridium core within Resolute Onyx DES increases visibility for accurate stent placement without compromising strut thickness.2Average visibility comparison2
(Higher is better)

- Cobalt alloy shell
- Platinum iridium core

Resolute Onyx cobalt alloy shell and platinum-iridum core
Smooth side branch access
Resolute Onyx DES has round struts to create a smooth passage when accessing the side branch and lower the propensity to catch during bifurcation procedures.2
Strut comparison
Rounded strut cross-section
- Resolute Onyx DES

Square strut cross-section
- SYNERGY™* DES
- XIENCE™* DES

Broadest diameter range
- Complex PCI requires a broad DES size matrix to match a wide range of patient anatomies.
- Resolute Onyx is the only DES with diameters ranging from 2.0 mm to 5.0 mm to treat a broad range of coronary vessel sizes.
Diameter (mm) Stent Length (mm) Maximum Expansion
Capabilities (MSID†) (mm)2.00 8 12 15 18 22 26 30 — — 3.50‡ 2.25 8 12 15 18 22 26 30 34 38 3.50‡ 2.50 8 12 15 18 22 26 30 34 38 3.50‡ 2.75 8 12 15 18 22 26 30 34 38 4.00‡ 3.00 8 12 15 18 22 26 30 34 38 4.00‡ 3.50 8 12 15 18 22 26 30 34 38 5.00‡ 4.00 8 12 15 18 22 26 30 34 38 5.00‡ 4.50 — 12 15 18 22 26 30 — — 6.00‡ 5.00 — 12 15 18 22 26 30 — — 6.00‡ PRODUCT DETAILS
2.00 RONYX20008X RONYX20012X RONYX20015X RONYX20018X RONYX20022X RONYX20026X RONYX20030X N/A N/A 2.25 RONYX22508X RONYX22512X RONYX22515X RONYX22518X RONYX22522X RONYX22526X RONYX22530X RONYX22534X RONYX22538X 2.50 RONYX25008X RONYX25012X RONYX25015X RONYX25018X RONYX25022X RONYX25026X RONYX25030X RONYX25034X RONYX25038X 2.75 RONYX27508X RONYX27512X RONYX27515X RONYX27518X RONYX27522X RONYX27526X RONYX27530X RONYX27534X RONYX27538X 3.00 RONYX30008X RONYX30012X RONYX30015X RONYX30018X RONYX30022X RONYX30026X RONYX30030X RONYX30034X RONYX30038X 3.50 RONYX35008X RONYX35012X RONYX35015X RONYX35015X RONYX35022X RONYX35026X RONYX35030X RONYX35034X RONYX35038X 4.00 RONYX40008X RONYX40012X RONYX40015X RONYX40018X RONYX40022X RONYX40026X RONYX40030X RONYX40034X RONYX40038X 4.50 N/A RONYX45012X RONYX45015X RONYX45018X RONYX45022X RONYX45026X RONYX45030X N/A N/A 5.00 N/A RONYX50012X RONYX50015X RONYX50018X RONYX50022X RONYX50026X RONYX5 -
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphora™ noncompliant balloon
NC Euphora™ noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora™ noncompliant balloon dilatation catheter has what you’re looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it — so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X NCEUP32508X NCEUP32512X 3.50 NCEUP3506X NCEUP3508X NCEUP3512X 3.75 NCEUP37506X NCEUP37508X NCEUP37512X 4.00 NCEUP4006X NCEUP4008X NCEUP4012X 4.50 — NCEUP4508X NCEUP4512X 5.00 — NCEUP5008X NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X — 2.25 NCEUP22515X NCEUP22520X — 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25 NCEUP32515X NCEUP32520X NCEUP32527X 3.50 NCEUP3515X NCEUP3520X NCEUP3527X 3.75 NCEUP37515X NCEUP37520X NCEUP37527X 4.00 NCEUP4015X NCEUP4020X NCEUP4027X 4.50 NCEUP4515X NCEUP4520X — 5.00 NCEUP5015X — — -
RADIFOCUS REDIAL SHEATH
Providing you the best range of Terumo Radifocus Radial Introducer Sheath and Cordis Femoral Introducer Sheath with effective & timely delivery.
The radial artery access sheath is used to gain arterial access and facilitate the insertion of catheters or other equipment for diagnostic and vascular interventions.
- The Cordis AVANTI®+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI®+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates procedural flexibility. It stays in place and allows patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and helps to minimize damage upon entry.
As part of the circulatory system, the radial artery supplies blood from the heart to the forearm.
Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.

















Reviews