CAPIOX® RX OXYGENATOR
Description
Oxygenator
Balanced Performance
- Low priming volume, high gas exchange and low pressure drop are optimally balanced for superb performance.
- Hollow fibers manufactured exclusively by Terumo using a patented technology with total quality management from raw materials to finished product.
- Woven fiber bundle ensures consistent and high-performance gas exchange.
- Choice of blood outlet port configurations for easy access and increased circuit flexibility.
- Top-to-bottom blood flow path and air purge line provide excellent air removal capability.
- No DEHP used in PVC tubing.
Hardshell Reservoir
Full Featured
- Elongated shape provides a stable blood flow path and enhanced visibility at all levels from all angles.
- Rotating venous inlet improves set-up flexibility.
- No DEHP used in PVC tubing.
- Connecting mount increases flexibility in circuit set-up and oxygenator rotation.
- Funnel-shaped cardiotomy filter improves breakthrough and residual volumes.
- Positive pressure relief value for additional safety.
Characteristics
- Terumo’s exclusive hollow fiber
- High flow with very low priming volume
- Superior O2 transfer performance
- Outstandingly low pressure drop
General specifications
Oxygenator
| Oxygenator | RX15 R30 reservoir | RX15 R40 reservoir | RX25 |
|---|---|---|---|
| Housing material | Polycarbonate | ||
| Fiber material | Microporous polypropylene | ||
| Heat exchanger material | Stainless steel | ||
| Fibers: Approx. surface area | 1.5 m² | 1.5 m² | 2.5 m² |
| Heat exchanger: Approx. surface area | 0.14 m² | 0.14 m² | 0.2 m² |
| Blood flow range | 0.5 – 4.0 L/min | 0.5 – 5.0 L/min | 0.5 – 7.0 L/min |
| Priming Volume (static) | 135 mL | 135 mL | 250 mL |
| Blood inlet port (from pump) | 3/8″ (9.5 mm) | ||
| Blood outlet port | 3/8″ (9.5 mm) | ||
| Cardioplegia port | 1/4″ (6.4 mm) | ||
| Gas inlet port | 1/4″ (6.4 mm) | ||
| Gas outlet port | 1/4″ (6.4 mm) | ||
| Water ports | 1/2″ (12.7 mm) Hansen quick connect fittings | ||
| Maximum pressure Blood inlet | 133 kPa (1.000 mmHg) | ||
| Maximum pressure Water inlet | 196 kPa (2 kgf/cm²)(28.5 psi) | ||
Hardshell reservoir
| Hardshell Reservoir | RX15 R30 reservoir | RX15 R40 reservoir | RX25 |
|---|---|---|---|
| Housing material | Polycarbonate | ||
| Venous filter materials | Polyester screen type | ||
| Cardiotomy filter material | Polyester depth type | ||
| Defoamer material | Polyurethane foam | ||
| Blood flow range: Venous | 0.5 – 4.0 L/min | 0.5 – 5.0 L/min | 0.5 – 7.0 L/min |
| Blood flow range: Cardiotomy inlet | 4.0 L/min | 5.0 L/min | 5.0 L/min |
| Blood flow range: Combined flow | 4.0 L/min | 5.0 L/min | 7.0 L/min |
| Blood storage capacity | 3.000 mL | 4.000 mL | 4.000 mL |
| Minimum operating volume | 70 mL | 200 mL | 200 mL |
| Venous blood inlet port (rotatable) > when 1/4″ adaptor is attached |
3/8″ (9.5 mm); 1/4″ (6.4 mm) |
1/2″ (12.7 mm) | |
| Blood outlet port (to pump) > when 1/4″ adaptor is attached |
3/8″ (9.5 mm); 1/4″ (6.4 mm) |
3/8″ (9.5 mm) | |
| Suction ports (rotatable) | Six: 1/4″ (6.4 mm) | ||
| Vertical port (to CR filter) | 3/8″ (9.5 mm) | ||
| Quick prime port | 1/4″ (6.4 mm) | ||
| Vent port | 1/4″ (6.4 mm) | ||
| Auxiliary port | 1/4″ – 3/8″ (6.4 mm – 9.5 mm) | ||
| Luer ports | Three filtered luer locks to cardiotomy filter, one non-filtered luer lock, two luer locks on venous inlet | ||
| Maximum sustainable negative pressure in reservoir | -20.0 kPa (-150 mmHg) | ||
Xcoating™ Surface Coating, Terumo Corporation’s biocompatible amphiphilic polymer surface coating, is a standard feature on the CAPIOX® RX Oxygenators.
Item specifications
Choose the blood outlet port configuration that best suits your circuit.
| West outlet port
Oxy inlet on right when outlet is
facing away from user
|
East outlet port
Oxy inlet on left when outlet is
facing away from user
|
Related products
-
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.
-
Everest30 INFLATION DEVICE
Everest 30
Disposable Inflation Device
OVERVIEW
Easy-to-use Rapid Inflation/Deflation Device
A simple solution for coronary balloon inflation. The Everest disposable inflation device features a quick trigger release and ergonomic pistol grip for ease of use. Plus, it’s available in your choice of 20 atm or 30 atm pressure gauge, and as a standalone or in a packaged kit.
PRODUCT DETAILS
The Everest Device Features:
- Quick trigger release so you can release pressure immediately, even at higher pressures
- Sure-grip torque knob with a ridged design for “no slip” torque control and precise pressure adjustment
- Unique ergonomic pistol grip with centered trigger that fits comfortably in either hand
- Luminescent dial face that provides accurate readability in normal and low-light conditions
EVEREST DISPOSABLE INFLATION DEVICE ORDERING INFORMATION
Disposable Inflation Device@ AC3200
Survival Kit Inflation Device@ AC305P
Everest20 inflation device
and 3-way stopcockAC2200 1 each Everest30 inflation device
and 3-way stopcockAC3200 1 each Everest20 Survival Kit: - Everest20 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC2205P 1 each Everest30 Survival Kit: - Everest30 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC3205P 1 each ACCESSORIES ORDERING INFORMATION
Metal guidewire insertion tool 006073 5 each Torque handle AC4006 5 each Piton™ Y-Adapter with metal guidewire insertion tool AC4001M 5 each Piton™ Tri-Adapter with metal guidewire insertion tool AC4002M 5 each Piton™ Y-Adapter with metal guidewire insertion tool and torque handle AC4003M 5 each -
Launcher- 7f Guiding Catheter’s
EBU@ (Extra Backup)
LA7EBU30 (EBU 3.0)
LA7EBU35 (EBU 3.5)
LA7EBU375 (EBU 3.75)
LA7EBU40 (EBU 4.0)
LA7EBU45 (EBU 4.5)
LA7EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA7JL30 (JL 3.0)
LA7JL35 (JL 3.5)
LA7JL40 (JL 4.0)
LA7JL45 (JL 4.5)
LA7JL50 (JL 5.0)
LA7JL60 (JL 6.0)
JR@ (Judkin Right )
LA7JR30 (JR 3.0)
LA7JR35 (JR 3.5)
LA7JR40 (JR 4.0)
LA7JR45 (JR 4.5)
LA7JR50 (JR 5.0)
LA7JR60 (JR 6.0)
AL@ (Amplatz Left )
LA7AL75 (AL .75)
LA7AL10 (AL 1.0)
LA7AL15 (AL 1.5)
LA7AL20 (AL 2.0)
LA7AL25 (AL 2.5)
LA7AL30 (AL 3.0)
LA7AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA7SAL75 (SAL . 75)
LA7SAL10 (SAL 1.0)
LA7SAL15 (SAL 1.5)
LA7SAL20 (SAL 2.0)
LA7SAL25 (SAL 2.5)
LA7SAL30 (SAL 3.0)
LA7SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA7AR10 (AR 1.0)
LA7AR20 (AR 2.0)
LA7ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA7ECR35 (ECR 3.5)
LA7ECR40 (ECR 4.0)
LA7ECR45 (ECR 4.5)
LA7RBU35 (RBU 3.5)
LA7RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA7SCR35 (SCR 3.5)
LA7SCR40 (SCR 4.0)
LA7SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA7SAR10 (SAR 1.0)
LA7SAR20 (SAR 2.0)
Multipurpose@
LA7MB1 (MB 1)
LA7MB2 (MB 2)
LA7HSREL (Hockey Stick)
LA7HSI (Hockey I)
LA7HSII (Hockey II)
LA7HSIII (Hockey III)
Bypass Crafts@
LA7LCB (LCB)
LA7RCB (RCB)
LA7RCB (RCB III)
LA7RCB (RCB 90cm)
LA7IMA (IMA)
LA7IMA (IMA 90cm)
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.OPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitors









Reviews
There are no reviews yet.