BOSTON 14 Promus Element Plus Drug Eluting Stent Boston
Focal Resistant Lesions
When blood flow is limited by a focal lesion and PTA is not sufficient to establish good patency due to calcium or vessel recoil
Restenotic Lesions
To treat flow-limiting restenosis consequent to PTA or BMS procedures
Short Dissections
When a dissection occurs immediately after PTA
Related products
-
Launcher- 8f Guiding Catheter’s
EBU@ (Extra Backup)
LA8EBU30 (EBU 3.0)
LA8EBU35 (EBU 3.5)
LA8EBU375 (EBU 3.75)
LA8EBU40 (EBU 4.0)
LA8EBU45 (EBU 4.5)
LA8EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA8JL30 (JL 3.0)
LA8JL35 (JL 3.5)
LA8JL40 (JL 4.0)
LA8JL45 (JL 4.5)
LA8JL50 (JL 5.0)
LA8JL60 (JL 6.0)
JR@ (Judkin Right )
LA8JR30 (JR 3.0)
LA8JR35 (JR 3.5)
LA8JR40 (JR 4.0)
LA8JR45 (JR 4.5)
LA8JR50 (JR 5.0)
LA8JR60 (JR 6.0)
AL@ (Amplatz Left )
LA8AL75 (AL .75)
LA8AL10 (AL 1.0)
LA8AL15 (AL 1.5)
LA8AL20 (AL 2.0)
LA8AL25 (AL 2.5)
LA8AL30 (AL 3.0)
LA8AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA8SAL75 (SAL . 75)
LA8SAL10 (SAL 1.0)
LA8SAL15 (SAL 1.5)
LA8SAL20 (SAL 2.0)
LA8SAL25 (SAL 2.5)
LA8SAL30 (SAL 3.0)
LA8SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA8AR10 (AR 1.0)
LA8AR20 (AR 2.0)
LA8ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA8ECR35 (ECR 3.5)
LA8ECR40 (ECR 4.0)
LA8ECR45 (ECR 4.5)
LA8RBU35 (RBU 3.5)
LA8RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA8SCR35 (SCR 3.5)
LA8SCR40 (SCR 4.0)
LA8SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA8SAR10 (SAR 1.0)
LA8SAR20 (SAR 2.0)
Multipurpose@
LA8MB1 (MB 1)
LA8MB2 (MB 2)
LA8HSREL (Hockey Stick)
LA8HSI (Hockey I)
LA8HSII (Hockey II)
LA8HSIII (Hockey III)
Bypass Crafts@
LA8LCB (LCB)
LA8RCB (RCB)
LA8RCB (RCB III)
LA8RCB (RCBÂ 90cm)
LA8IMA (IMA)
LA8IMA (IMAÂ 90cm)
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.ÂOPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitors -
NC Sprinter PTCA BALLOON
NC Sprinter RX Noncompliant
NC Stormer over-the-wire noncompliant balloon dilatation catheter offers controlled compliance, high pressures, and comprehensive lengths.
Balloon Dilatation Catheter
OVERVIEW
The NC Sprinterâ„¢ RX noncompliant coronary balloon combines:
- Sprinter crossing technology
- High-pressure capability and controlled expansion1
ORDERING INFORMATION
BALLOON LENGTHS 6, 9, 12 MM
Balloon Diameter (mm)
Balloon Length (mm)     6 9 12 2.00 NCSP2006X NCSP2009X NCSP2012X 2.25 NCSP22506X — NCSP22512X 2.50 NCSP2506X NCSP2509X NCSP2512X 2.75 NCSP27506X NCSP27509X NCSP27512X 3.00 NCSP3006X NCSP3009X NCSP3012X 3.25 NCSP32506X NCSP32509X NCSP32512X 3.50 NCSP3506X NCSP3509X NCSP3512X 3.75 NCSP37506X NCSP37509X NCSP37512X 4.00 NCSP4006X NCSP4009X NCSP4012X 4.50 — — — 5.00 — — — BALLOON LENGTHS 15, 21, 27 MM
Balloon Diameter (mm)
Balloon Length (mm)     15 21 27 2.00 NCSP2015X NCSP2021X — 2.25 — NCSP22521X — 2.50 NCSP2515X NCSP2521X NCSP2527X 2.75 NCSP27515X NCSP27521X — 3.00 NCSP3015X NCSP3021X NCSP3027X 3.25 NCSP32515X NCSP32521X — 3.50 NCSP3515X NCSP3521X NCSP3527X 3.75 NCSP37515X NCSP37521X — 4.00 NCSP4015X NCSP4021X NCSP4027X 4.50 NCSP4515X NCSP4521X — 5.00 NCSP5015X — — -
RADIFOCUS REDIAL SHEATH
Providing you the best range of Terumo Radifocus Radial Introducer Sheath and Cordis Femoral Introducer Sheath with effective & timely delivery.
The radial artery access sheath is used to gain arterial access and facilitate the insertion of catheters or other equipment for diagnostic and vascular interventions.
- The Cordis AVANTI®+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI®+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates procedural flexibility. It stays in place and allows patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and helps to minimize damage upon entry.
As part of the circulatory system, the radial artery supplies blood from the heart to the forearm.
Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.









Reviews
There are no reviews yet.