AVANTI TRANSREDIAL SHEATH
Cordis AVANTIâ„¢+ Sheath Introducer
Smooth performance
from start to finish
The proven cannula offers reliable,
smooth performance from start to finish
• For smooth, atraumatic insertion
• Kink resistant
• Optimized catheter maneuverability
with minimal leakage
For smooth, atraumatic insertion
– Manicured tip insures smooth transition of the introducer as it crosses the miniguidewire into the artery during initial insertion
– Smooth transitions between cannula, guidewire and dilator for:
• effortless vessel entry
• increased patient comfort
• smallest possible risk for complications
Insertion Force
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
Insertion Force (lbf)
Endovascular Catalogue Numbers
5.5cm 11cm 23cm
Cannula Cannula Cannula
French Colour With Without With Without Without
size code mini-wire mini-wire mini-wire mini-wire mini-wire
4 n 402-604P 402-604X 402-604A
5 n 402-605P 402-605X 402-605A 402-605T
5.5** n 402-655X
6 n 402-606P 402-606R 402-606X 402-606A 402-606T
6.5** n 402-656X
7 n 402-607P 402-607R 402-607X 402-607A
8 n 402-608X 402-608A 402-608T
9 n 402-609X 402-609A 402-609T
10 n 402-610X 402-610A
11 n 402-611X
Smooth Performance from Start to Finish
**
5F MS = Mid-Size = 5.5F
6F MS = Mid-Size = 6.5F
French Colour Mini-wire With Without
size code (inch) mini-wire mini-wire
4 n .035 504-604X 504-604A
5 n .038 504-605X 504-605A
5.5** n .038 504-655X*
6 n .038 504-606X 504-606A
6.5** n .038 504-656X* 504-656A*
7 n .038 504-607X 504-607A
7.5** n .038 504-657X*
8 n .038 504-608X 504-608A
8.5** n .038 504-658X*
9 n .038 504-609X 504-609A
10 n .038 504-610X 504-610A
11 n .038 504-611X
* Monitoring sheath: provides slightly larger ID for pressure monitoring or side port aspiration with a catheter in place; they are one-half French size larger in size
** 5F MS = Mid-Size = 5.5F
6F MS = Mid-Size = 6.5F
7F MS = Mid-Size = 7.5F
8F MS = Mid-Size = 8.5F
** 6F MS= Mid-Size=6.5FC
French Colour Dilator usable With Without
size code (cm) obturator obturator
4 n 30 504-604T
5 n 30 504-605T
6 n 30 504-606D 504-606T
6.5** n 30 504-656T*
7 n 30 504-607D 504-607T
8 n 30 504-608D 504-608T
10 n 30 504-610T
11 n 30 504-611TC
French Colour Mini-wire Catalogue
size code (inch) number
6 n .038 504-606V
7 n .038 504-607V
8 n .038 504-608V
French Colour Mini-wire Catalogue
size code (inch) number
4 n .035 504-604P
5 n .038 504-605P
6 n .038 504-606P
French Colour Mini-wire Catalogue
size code (inch) number
4 n .021 504-604S
5 n .021 504-605S
6 n .021 504-606S
French Colour Wire acceptance Catalogue Wire acceptance Catalogue
size code (inch) number (inch) number
4 n .021 504-614Z .021 70 cm 504-624Z
5 n .021 504-615Z .021 70 cm 504-625Z
6 n .021 504-616Z .021 70 cm 504-626Z
AVANTI TRANSREDIAL SHEATH
Related products
-
Launcher- 5f Guiding Catheter’s
EBU@ (Extra Backup)
LA5EBU30 (EBU 3.0)
LA5EBU35 (EBU 3.5)
LA5EBU375 (EBU 3.75)
LA5EBU40 (EBU 4.0)
LA5EBU45 (EBU 4.5)
LA5EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA5JL30 (JL 3.0)
LA5JL35 (JL 3.5)
LA5JL40 (JL 4.0)
LA5JL45 (JL 4.5)
LA5JL50 (JL 5.0)
LA5JL60 (JL 6.0)
JR@ (Judkin Right )
LA5JR30 (JR 3.0)
LA5JR35 (JR 3.5)
LA5JR40 (JR 4.0)
LA5JR45 (JR 4.5)
LA5JR50 (JR 5.0)
LA5JR60 (JR 6.0)
AL@ (Amplatz Left )
LA5AL75 (AL .75)
LA5AL10 (AL 1.0)
LA5AL15 (AL 1.5)
LA5AL20 (AL 2.0)
LA5AL25 (AL 2.5)
LA5AL30 (AL 3.0)
LA5AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA5SAL75 (SAL . 75)
LA5SAL10 (SAL 1.0)
LA5SAL15 (SAL 1.5)
LA5SAL20 (SAL 2.0)
LA5SAL25 (SAL 2.5)
LA5SAL30 (SAL 3.0)
LA5SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA5AR10 (AR 1.0)
LA5AR20 (AR 2.0)
LA5ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA5ECR35 (ECR 3.5)
LA5ECR40 (ECR 4.0)
LA5ECR45 (ECR 4.5)
LA5RBU35 (RBU 3.5)
LA5RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA5SCR35 (SCR 3.5)
LA5SCR40 (SCR 4.0)
LA5SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA5SAR10 (SAR 1.0)
LA5SAR20 (SAR 2.0)
Multipurpose@
LA5MB1 (MB 1)
LA5MB2 (MB 2)
LA5HSREL (Hockey Stick)
LA5HSI (Hockey I)
LA5HSII (Hockey II)
LA5HSIII (Hockey III)
Bypass Crafts@
LA5LCB (LCB)
LA5RCB (RCB)
LA5RCB (RCB III)
LA5RCB (RCBÂ 90cm)
LA5IMA (IMA)
LA5IMA (IMAÂ 90cm)
-
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinterâ„¢ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinterâ„¢ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Â Selective Dura-Trac coating
- Â 2.5 mm tip
- Â FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip
-
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphoraâ„¢ noncompliant balloon
NC Euphora™ noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora™ noncompliant balloon dilatation catheter has what you’re looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it — so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X  NCEUP32508X  NCEUP32512X 3.50 NCEUP3506X  NCEUP3508X  NCEUP3512X 3.75 NCEUP37506X  NCEUP37508X  NCEUP37512X 4.00 NCEUP4006X  NCEUP4008X  NCEUP4012X 4.50  —  NCEUP4508X  NCEUP4512X 5.00  —  NCEUP5008X  NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X — 2.25 NCEUP22515X NCEUP22520X — 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25  NCEUP32515X  NCEUP32520X  NCEUP32527X 3.50  NCEUP3515X  NCEUP3520X  NCEUP3527X 3.75  NCEUP37515X  NCEUP37520X  NCEUP37527X 4.00  NCEUP4015X  NCEUP4020X  NCEUP4027X 4.50  NCEUP4515X  NCEUP4520X  — 5.00  NCEUP5015X —  — -
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.







Reviews
There are no reviews yet.