ASAHI SIONĀ® blue
ASAHI SIONĀ® blue
Well Balanced Workhorse
Frontline guide wire with proprietary ACT ONE construction for greater tip flexibility, durability and torque response.
(Easily-discernible shaft color for differentiation from other ASAHI wires.)

| TIP LOAD | |
| TIP RADIOPACITY | 3 cm |
| COATING | HYBRID COATING: HYDROPHILIC* WITH HYDROPHOBIC TIP Hydrophobic Coating: Tip to 1.5 cm Hydrophilic Coating: 18.5 cm |
| TIP SHAPE | ![]() ![]() |

Resources
Guide wire differences between Torque and no Torque
Traversing a tortuous vessel, whether for Interventional Cardiology or Interventional Neurology can require a guide wire that is an extended version of the Interventional Cardiologist or Neurologist own finger. To achieve this, torque technology, like ASAHIās own patented guide wires, is needed for accurate pushback and little to no whip. See a firsthand example of a guide wire with and without this torque ability.
Crossing the Y-Branch
A side branch occlusion? a tortuous vessel? Not a problem with the right ASAHI INTECC guide wire technology. See it for yourself!
Ordering Information
To order, please call us toll-free at 855-286-9473, or email us atĀ customersupport@asahi-intecc.com. To see a complete listing of all available ASAHI products, go to ourĀ Full Product ListingĀ page.
| PRODUCT | CATALOG NO. | TIP SHAPE | LENGTH (CM) | DIAMETER (INCH(MM)) | RADIOPAQUE SEGMENT (CM) | SPRING COIL LENGTH (CM) | COATING |
|---|---|---|---|---|---|---|---|
| ASAHI SION blueĀ PTCA GW 190 cm, Straight | AHW14R104S | Straight | 190 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 190 cm, J Shape | AHW14R104J | J Shape | 190 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 300 cm, Straight | AHW14R304S | Straight | 300 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 300 cm, J Shape | AHW14R304J | J Shape | 300 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
*Coated with SLIP-COAT® coating
Indications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
Related products
-
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance⢠aspiration catheter delivers consistent, high-performing aspiration power when it matters most ā restoring flow and protecting patients.
PRODUCT DETAILSā
Superior Deliverability1
Full-Wall TechnologyĀ provides variable levels of stiffness without joints, for optimalĀ kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffnessĀ during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibilityĀ allows for extra support, when needed.ā
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.ā”
- Optimised hub geometry improves flow.ā”
- Soft, short, forward-facing tip design permits excellent particle capture.ā
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ā¢Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export⢠AP catheter.
- Bench testing vs. Terumo Eliminateā¢* and Eliminateā¢* 3 aspiration catheters, Vascular Solutions ProntoĀ®*Ā LP, ProntoĀ®*Ā V3 and ProntoĀ®*Ā V4 aspiration catheters, MeritĀ®*Ā ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCatā¢* aspiration catheter, IHT Polska HunterĀ®* aspiration catheter, Medrad Possisā¢* Fetchā¢* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export⢠AP aspiration catheter without stylet.
-
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphora⢠noncompliant balloon
NC Euphora⢠noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora⢠noncompliant balloon dilatation catheter has what youāre looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it ā so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X Ā NCEUP32508X Ā NCEUP32512X 3.50 NCEUP3506X Ā NCEUP3508X Ā NCEUP3512X 3.75 NCEUP37506X Ā NCEUP37508X Ā NCEUP37512X 4.00 NCEUP4006X Ā NCEUP4008X Ā NCEUP4012X 4.50 Ā ā Ā NCEUP4508X Ā NCEUP4512X 5.00 Ā ā Ā NCEUP5008X Ā NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X ā 2.25 NCEUP22515X NCEUP22520X ā 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25 Ā NCEUP32515X Ā NCEUP32520X Ā NCEUP32527X 3.50 Ā NCEUP3515X Ā NCEUP3520X Ā NCEUP3527X 3.75 Ā NCEUP37515X Ā NCEUP37520X Ā NCEUP37527X 4.00 Ā NCEUP4015X Ā NCEUP4020X Ā NCEUP4027X 4.50 Ā NCEUP4515X Ā NCEUP4520X Ā ā 5.00 Ā NCEUP5015X ā Ā ā -
PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- āProvides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
Shaft diameter 1.9 Fr / 0.64Ā mm Proximal
2.5 Fr / 0.84 mm Mid
2.6 Fr / 0.86 mm DistalUsable length 145 cm Balloon markers 2 Nominal pressure 12 atm / 1216 kPa Rated burst pressure 22 atm / 2229 kPa (2.0 mm to 4.0 mm)
20 atm / 2026 kPa (4.5 and 5.0 mm)Guidewire compatibility Maximum diameter 0.014″ / 0.36 mm Lesion entry profile 0.43 mm Coating Hydrophilic Item specifications
Ordering Information
Balloon
diameter
(mm) āBalloon length (mm) /Ā Item referencesĀ ā ā ā ā ā ā 6 8 12 15 20 25 30 2.00 DC-RM2006HSW DC-RM2008HSW DC-RM2012HHW DC-RM2015HHW DC-RM2020HHW ā ā 2.25 DC-RM2206HSW DC-RM2208HSW DC-RM2212HHW DC-RM2215HHW DC-RM2220HHW ā ā 2.50 DC-RM2506HSW DC-RM2508HSW DC-RM2512HHW DC-RM2515HHW DC-RM2520HHW DC-RM2525HHW DC-RM2530HHW 2.75 DC-RM2706HSW DC-RM2708HSW DC-RM2712HHW DC-RM2715HHW DC-RM2720HHW ā ā 3.00 DC-RM3006HSW DC-RM3008HSW DC-RM3012HHW DC-RM3015HHW DC-RM3020HHW DC-RM3025HHW DC-RM3030HHW 3.25 DC-RM3206HSW DC-RM3208HSW DC-RM3212HHW DC-RM3215HHW DC-RM3220HHW ā ā 3.50 DC-RM3506HSW DC-RM3508HSW DC-RM3512HHW DC-RM3515HHW DC-RM3520HHW DC-RM3525HHW DC-RM3530HHW 3.75 DC-RM3706HSW DC-RM3708HSW DC-RM3712HHW DC-RM3715HHW DC-RM3720HHW ā ā 4.00 DC-RM4006HSW DC-RM4008HSW DC-RM4012HHW DC-RM4015HHW DC-RM4020HHW ā ā 4.50 DC-RM4506HSW DC-RM4508HSW DC-RM4512HSW DC-RM4515HSW ā ā ā 5.00 DC-RM5006HSW DC-RM5008HSW DC-RM5012HSW DC-RM5015HSW ā ā ā Please quote above item reference codes when placing an order.
Balloon Compliance
Balloon
diameter
(mm) āPressure (atm)Ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā ā 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2.00 1.58 1.65 1.72 1.79 1.84 1.88 1.92 1.95 1.98 2.00* 2.01 2.03 2.04 2.05 2.06 2.08 2.09 2.10 2.12 2.13** 2.14 2.15 2.17 2.25 1.96 2.01 2.06 2.11 2.14 2.16 2.19 2.21 2.23 2.25* 2.26 2.28 2.29 2.31 2.32 2.34 2.35 2.36 2.38 2.39** 2.41 2.42 2.44 2.50 2.19 2.24 2.30 2.36 2.38 2.41 2.44 2.46 2.48 2.50* 2.52 2.53 2.55 2.56 2.58 2.60 2.61 2.63 2.64 2.66** 2.68 2.69 2.71 2.75 2.43 2.48 2.53 2.59 2.62 2.65 2.67 2.70 2.73 2.75* 2.77 2.79 2.80 2.82 2.84 2.86 2.87 2.89 2.91 2.93** 2.94 2.96 2.98 3.00 2.65 2.71 2.76 2.82 2.85 2.89 2.92 2.95 2.97 3.00* 3.02 3.04 3.06 3.08 3.10 3.11 3.13 3.15 3.17 3.19** 3.21 3.23 3.25 3.25 2.89 2.95 3.01 3.07 3.10 3.14 3.17 3.20 3.22 3.25* 3.27 3.29 3.31 3.33 3.35 3.37 3.39 3.42 3.44 3.46** 3.47 3.48 3.51 3.50 3.13 3.19 3.26 3.32 3.35 3.39 3.42 3.45 3.47 3.50* 3.52 3.54 3.57 3.59 3.61 3.63 3.65 3.68 3.70 3.72** 3.74 3.74 3.76 3.75 3.37 3.44 3.50 3.56 3.60 3.63 3.66 3.69 3.72 3.75* 3.77 3.80 3.82 3.84 3.86 3.88 3.90 3.92 3.94 3.96** 3.98 3.99 4.01 4.00 3.58 3.65 3.72 3.79 3.83 3.87 3.90 3.94 3.97 4.00* 4.03 4.05 4.07 4.09 4.11 4.13 4.15 4.17 4.19 4.21** 4.23 4.26 4.28 4.50 4.02 4.10 4.19 4.28 4.32 4.37 4.40 4.44 4.47 4.50* 4.53 4.56 4.59 4.63 4.66 4.68 4.71 4.75** 4.78 4.81 4.84 4.87 4.91 5.00 4.52 4.59 4.67 4.75 4.80 4.85 4.89 4.93 4.96 5.00* 5.03 5.07 5.10 5.13 5.16 5.19 5.22 5.26** 5.29 5.32 5.35 5.38 5.41 * Nominal pressure
** Rated burst pressureReferences
āā1Ā Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Ordering Information.Ā BalloonĀ diameter (mm) ā,Ā BalloonĀ length (mm) / Item references ā ā ā ā ā ā.Balloon markers:Ā 2Usable length:Ā 145 cmCoating:Ā HydrophilicLesion entry profile:Ā 0.43 mmStraight-Single Latex PlasticĀ Terumo Accuforce BalloonĀ Catheter, Size: Medium ; Application, Hospital ; Brand,Ā TerumoĀ ; Material, Latex ; Inner Diameter, 36mm. -
Launcher- 5f Guiding Catheter’s
EBU@ (Extra Backup)
LA5EBU30 (EBU 3.0)
LA5EBU35 (EBU 3.5)
LA5EBU375 (EBU 3.75)
LA5EBU40 (EBU 4.0)
LA5EBU45 (EBU 4.5)
LA5EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA5JL30 (JL 3.0)
LA5JL35 (JL 3.5)
LA5JL40 (JL 4.0)
LA5JL45 (JL 4.5)
LA5JL50 (JL 5.0)
LA5JL60 (JL 6.0)
JR@ (Judkin Right )
LA5JR30 (JR 3.0)
LA5JR35 (JR 3.5)
LA5JR40 (JR 4.0)
LA5JR45 (JR 4.5)
LA5JR50 (JR 5.0)
LA5JR60 (JR 6.0)
AL@ (Amplatz Left )
LA5AL75 (AL .75)
LA5AL10 (AL 1.0)
LA5AL15 (AL 1.5)
LA5AL20 (AL 2.0)
LA5AL25 (AL 2.5)
LA5AL30 (AL 3.0)
LA5AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA5SAL75 (SAL . 75)
LA5SAL10 (SAL 1.0)
LA5SAL15 (SAL 1.5)
LA5SAL20 (SAL 2.0)
LA5SAL25 (SAL 2.5)
LA5SAL30 (SAL 3.0)
LA5SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA5AR10 (AR 1.0)
LA5AR20 (AR 2.0)
LA5ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA5ECR35 (ECR 3.5)
LA5ECR40 (ECR 4.0)
LA5ECR45 (ECR 4.5)
LA5RBU35 (RBU 3.5)
LA5RBU40 (RBU 4.0)
SCR@ (Shepherdās Crook Right)
LA5SCR35 (SCR 3.5)
LA5SCR40 (SCR 4.0)
LA5SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA5SAR10 (SAR 1.0)
LA5SAR20 (SAR 2.0)
Multipurpose@
LA5MB1 (MB 1)
LA5MB2 (MB 2)
LA5HSREL (Hockey Stick)
LA5HSI (Hockey I)
LA5HSII (Hockey II)
LA5HSIII (Hockey III)
Bypass Crafts@
LA5LCB (LCB)
LA5RCB (RCB)
LA5RCB (RCB III)
LA5RCB (RCBĀ 90cm)
LA5IMA (IMA)
LA5IMA (IMAĀ 90cm)










Reviews
There are no reviews yet.