ASAHI SIONĀ® blue
ASAHI SIONĀ® blue
Well Balanced Workhorse
Frontline guide wire with proprietary ACT ONE construction for greater tip flexibility, durability and torque response.
(Easily-discernible shaft color for differentiation from other ASAHI wires.)

| TIP LOAD | |
| TIP RADIOPACITY | 3 cm |
| COATING | HYBRID COATING: HYDROPHILIC* WITH HYDROPHOBIC TIP Hydrophobic Coating: Tip to 1.5 cm Hydrophilic Coating: 18.5 cm |
| TIP SHAPE | ![]() ![]() |

Resources
Guide wire differences between Torque and no Torque
Traversing a tortuous vessel, whether for Interventional Cardiology or Interventional Neurology can require a guide wire that is an extended version of the Interventional Cardiologist or Neurologist own finger. To achieve this, torque technology, like ASAHIās own patented guide wires, is needed for accurate pushback and little to no whip. See a firsthand example of a guide wire with and without this torque ability.
Crossing the Y-Branch
A side branch occlusion? a tortuous vessel? Not a problem with the right ASAHI INTECC guide wire technology. See it for yourself!
Ordering Information
To order, please call us toll-free at 855-286-9473, or email us atĀ customersupport@asahi-intecc.com. To see a complete listing of all available ASAHI products, go to ourĀ Full Product ListingĀ page.
| PRODUCT | CATALOG NO. | TIP SHAPE | LENGTH (CM) | DIAMETER (INCH(MM)) | RADIOPAQUE SEGMENT (CM) | SPRING COIL LENGTH (CM) | COATING |
|---|---|---|---|---|---|---|---|
| ASAHI SION blueĀ PTCA GW 190 cm, Straight | AHW14R104S | Straight | 190 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 190 cm, J Shape | AHW14R104J | J Shape | 190 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 300 cm, Straight | AHW14R304S | Straight | 300 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 300 cm, J Shape | AHW14R304J | J Shape | 300 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
*Coated with SLIP-COAT® coating
Indications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
Related products
-
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphora⢠noncompliant balloon
NC Euphora⢠noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora⢠noncompliant balloon dilatation catheter has what youāre looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it ā so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X Ā NCEUP32508X Ā NCEUP32512X 3.50 NCEUP3506X Ā NCEUP3508X Ā NCEUP3512X 3.75 NCEUP37506X Ā NCEUP37508X Ā NCEUP37512X 4.00 NCEUP4006X Ā NCEUP4008X Ā NCEUP4012X 4.50 Ā ā Ā NCEUP4508X Ā NCEUP4512X 5.00 Ā ā Ā NCEUP5008X Ā NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X ā 2.25 NCEUP22515X NCEUP22520X ā 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25 Ā NCEUP32515X Ā NCEUP32520X Ā NCEUP32527X 3.50 Ā NCEUP3515X Ā NCEUP3520X Ā NCEUP3527X 3.75 Ā NCEUP37515X Ā NCEUP37520X Ā NCEUP37527X 4.00 Ā NCEUP4015X Ā NCEUP4020X Ā NCEUP4027X 4.50 Ā NCEUP4515X Ā NCEUP4520X Ā ā 5.00 Ā NCEUP5015X ā Ā ā -
Launcher- 6f Guiding Catheterās
EBU@ (Extra Backup)
LA6EBU30 (EBU 3.0)
LA6EBU35 (EBU 3.5)
LA6EBU375 (EBU 3.75)
LA6EBU40 (EBU 4.0)
LA6EBU45 (EBU 4.5)
LA6EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA6JL30 (JL 3.0)
LA6JL35 (JL 3.5)
LA6JL40 (JL 4.0)
LA6JL45 (JL 4.5)
LA6JL50 (JL 5.0)
LA6JL60 (JL 6.0)
JR@ (Judkin Right )
LA6JR30 (JR 3.0)
LA6JR35 (JR 3.5)
LA6JR40 (JR 4.0)
LA6JR45 (JR 4.5)
LA6JR50 (JR 5.0)
LA6JR60 (JR 6.0)
AL@ (Amplatz Left )
LA6AL75 (AL .75)
LA6AL10 (AL 1.0)
LA6AL15 (AL 1.5)
LA6AL20 (AL 2.0)
LA6AL25 (AL 2.5)
LA6AL30 (AL 3.0)
LA6AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA6SAL75 (SAL . 75)
LA6SAL10 (SAL 1.0)
LA6SAL15 (SAL 1.5)
LA6SAL20 (SAL 2.0)
LA6SAL25 (SAL 2.5)
LA6SAL30 (SAL 3.0)
LA6SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA6AR10 (AR 1.0)
LA6AR20 (AR 2.0)
LA6ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA6ECR35 (ECR 3.5)
LA6ECR40 (ECR 4.0)
LA6ECR45 (ECR 4.5)
LA6RBU35 (RBU 3.5)
LA6RBU40 (RBU 4.0)
SCR@ (Shepherdās Crook Right)
LA6SCR35 (SCR 3.5)
LA6SCR40 (SCR 4.0)
LA6SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA6SAR10 (SAR 1.0)
LA6SAR20 (SAR 2.0)
Multipurpose@
LA6MB1 (MB 1)
LA6MB2 (MB 2)
LA6HSREL (Hockey Stick)
LA6HSI (Hockey I)
LA6HSII (Hockey II)
LA6HSIII (Hockey III)
Bypass Crafts@
LA6LCB (LCB)
LA6RCB (RCB)
LA6RCB (RCB III)
LA6RCB (RCBĀ 90cm)
LA6IMA (IMA)
LA6IMA (IMAĀ 90cm)
-
Coronary Diagnostic Catheter (OPTITORQUE)
PRODUCT OVERVIEW
A complete line of coronary diagnostic catheters designed for superior torque control and precise placement.
RADIAL-SPECIFIC UNIVERSAL SHAPES
- Radial Specific curves designed to enable support and alignment during catheterization1
- Excellent back-up support for angiography of both RCA and LCA with a single catheter1,a
- Universal design eliminates the need for catheter exchanges and potentially shortens procedural and fluoroscopic time
1. DOF Reference
a. when compared to leading competitors
2. Ikaria article.ĀOPTITORQUE Classic Shapes
Shape Category Product Code
5 Fr / 1.70 mmProduct Code
6 Fr / 2.00 mmShape Name (cm) Length Holes Side Tip Shape Pigtail 40-5030 40-6030 Straight Pigtail 110 6 40-5031 40-6031 Angled Pigtail 155° 110 6 Judkins Left 40-5040 40-6040 JL 3.5 (Judkins Left 3.5 cm) 100 40-5041 40-6041 JL 4.0 (Judkins Left 4.0 cm) 100 40-5042 40-6042 JL 5.0 (Judkins Left 5.0 cm) 100 Judkins Right 40-5043 40-6043 JR 3.5 (Judkins Right 3.5 cm) 100 40-5044 40-6044 JR 4.0 (Judkins Right 4.0 cm) 100 40-5045 JR 5.0 (Judkins Right 5.0 cm) 100 Bypass 40-5050 40-6050 Internal Mammary 100 Amplatz 40-5060 AL 1 (Amplatz Left Small Type) 100 40-5061 40-6061 AL 2 (Amplatz Left Middle Type) 100 UNIQUE DESIGN
- Designed for coaxial alignment to the ostium, allowing the catheter to sit at the appropriate angle for optimal engagement
- Large lumen allows high flow of contrast media and allows downsizing of French size
PROVEN PERFORMANCE
- Superior torqueability for precise placement1,a
- Excellent trackability in tortuous anatomy while navigating the radial artery1,a
- Superior flow rates for diagnostic imaging1,a
1.DOF
a. When compared to leading competitorsĀ -
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance⢠aspiration catheter delivers consistent, high-performing aspiration power when it matters most ā restoring flow and protecting patients.
PRODUCT DETAILSā
Superior Deliverability1
Full-Wall TechnologyĀ provides variable levels of stiffness without joints, for optimalĀ kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffnessĀ during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibilityĀ allows for extra support, when needed.ā
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.ā”
- Optimised hub geometry improves flow.ā”
- Soft, short, forward-facing tip design permits excellent particle capture.ā
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ā¢Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export⢠AP catheter.
- Bench testing vs. Terumo Eliminateā¢* and Eliminateā¢* 3 aspiration catheters, Vascular Solutions ProntoĀ®*Ā LP, ProntoĀ®*Ā V3 and ProntoĀ®*Ā V4 aspiration catheters, MeritĀ®*Ā ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCatā¢* aspiration catheter, IHT Polska HunterĀ®* aspiration catheter, Medrad Possisā¢* Fetchā¢* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export⢠AP aspiration catheter without stylet.










Reviews
There are no reviews yet.