ASAHI SIONĀ® blue
ASAHI SIONĀ® blue
Well Balanced Workhorse
Frontline guide wire with proprietary ACT ONE construction for greater tip flexibility, durability and torque response.
(Easily-discernible shaft color for differentiation from other ASAHI wires.)

| TIP LOAD | |
| TIP RADIOPACITY | 3 cm |
| COATING | HYBRID COATING: HYDROPHILIC* WITH HYDROPHOBIC TIP Hydrophobic Coating: Tip to 1.5 cm Hydrophilic Coating: 18.5 cm |
| TIP SHAPE | ![]() ![]() |

Resources
Guide wire differences between Torque and no Torque
Traversing a tortuous vessel, whether for Interventional Cardiology or Interventional Neurology can require a guide wire that is an extended version of the Interventional Cardiologist or Neurologist own finger. To achieve this, torque technology, like ASAHIās own patented guide wires, is needed for accurate pushback and little to no whip. See a firsthand example of a guide wire with and without this torque ability.
Crossing the Y-Branch
A side branch occlusion? a tortuous vessel? Not a problem with the right ASAHI INTECC guide wire technology. See it for yourself!
Ordering Information
To order, please call us toll-free at 855-286-9473, or email us atĀ customersupport@asahi-intecc.com. To see a complete listing of all available ASAHI products, go to ourĀ Full Product ListingĀ page.
| PRODUCT | CATALOG NO. | TIP SHAPE | LENGTH (CM) | DIAMETER (INCH(MM)) | RADIOPAQUE SEGMENT (CM) | SPRING COIL LENGTH (CM) | COATING |
|---|---|---|---|---|---|---|---|
| ASAHI SION blueĀ PTCA GW 190 cm, Straight | AHW14R104S | Straight | 190 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 190 cm, J Shape | AHW14R104J | J Shape | 190 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 300 cm, Straight | AHW14R304S | Straight | 300 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
| ASAHI SION blueĀ PTCA GW 300 cm, J Shape | AHW14R304J | J Shape | 300 | 0.014 (0.36) | 3 | 20 | Hybrid Coating: Hydrophilic* with Hydrophobic Tip |
*Coated with SLIP-COAT® coating
Indications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
Related products
-
SPRINTER LEGEND PTCA BALLOON
SPRINTER LEGEND 1.25 BALLOON CATHETER
Super Crosser Semi compliant Balloon Dilatation Catheter (RX/OTW)
Sprinter⢠Legend⢠1.25 SuperCrosser semicompliant balloon dilatation catheter delivers exceptional crossability to treat todayās challenging lesions.
With innovative crossing technologies and 57 sizes, the Sprinterā¢Ā Legend⢠RX semicompliant balloon dilatation catheter provides you with the power to cross.
OVERVIEW
During difficult cases, reach for a slim Sprinter⢠Legend⢠1.25 mm Super Crosser semi compliant coronary balloon catheter featuring:
- Award-winning*Ā Zerofold technology ā no wrapped material and no balloon shoulders
- Low 0.5 mm (0.020 in) crossing profile
- OTW and RX platforms
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
1.25 SPL12506WL SPL12510WL SPL12515WL SPL12520WL Sprinter Legend RX Semi compliant
Balloon Dilatation Catheter
OVERVIEW
Performance You Can Trust
Sprinter⢠Legend⢠semicompliant balloons help you cross, open, and treat lesions during challenging percutaneous coronary interventions (PCIs), and feature:
- Some of the industryās lowest crossing profiles1
- Innovative crossing technology
- A broad range of sizes
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
Balloon Diameter (mm)
1.25 SPL12506X SPL12510X SPL12512X SPL12515X 1.50 SPL15006X SPL15010X SPL15012X SPL15015X 2.00 SPL20006X SPL20010X SPL20012X SPL20015X 2.25 SPL22506X SPL22510X SPL22512X SPL22515X 2.50 SPL25006X SPL25010X SPL25012X SPL25015X 2.75 SPL27506X ā SPL27512X SPL27515X 3.00 SPL30006X SPL30010X SPL30012X SPL30015X 3.25 ā ā SPL32512X SPL32515X 3.50 SPL35006X SPL35010X SPL35012X SPL35015X 3.75 ā ā SPL37512X SPL37515X 4.00 SPL40006X SPL40010X SPL40012X SPL40015X BALLOON LENGTHS 20, 25, AND 30 MM
Balloon Diameter (mm)
1.25 SPL12520X ā ā 1.50 SPL15020X ā ā 2.00 SPL20020X SPL20025X SPL20030X 2.25 SPL22520X SPL22525X ā 2.50 SPL25020X SPL25025X SPL25030X 2.75 SPL27520X SPL27525X ā 3.00 SPL30020X SPL30025X SPL30030X 3.25 SPL32520X ā ā 3.50 SPL35020X SPL35025X SPL35030X 3.75 SPL37520X ā ā 4.00 SPL40020X SPL40025X SPL40030X -
Everest30 INFLATION DEVICE
Everest 30
Disposable Inflation Device
OVERVIEW
Easy-to-use Rapid Inflation/Deflation DeviceĀ
A simple solution for coronary balloon inflation. The Everest disposable inflation device features a quick trigger release and ergonomic pistol grip for ease of use. Plus, itās available in your choice of 20 atm or 30 atm pressure gauge, and as a standalone or in a packaged kit.
PRODUCT DETAILS
The Everest Device Features:
- Quick trigger release so you can release pressure immediately, even at higher pressures
- Sure-grip torque knob with a ridged design for āno slipā torque control and precise pressure adjustment
- Unique ergonomic pistol grip with centered trigger that fits comfortably in either hand
- Luminescent dial face that provides accurate readability in normal and low-light conditions
EVEREST DISPOSABLE INFLATION DEVICE ORDERING INFORMATION
Disposable Inflation Device@ AC3200
Survival Kit Inflation Device@ AC305P
Everest20 inflation device
and 3-way stopcockAC2200 1 each Everest30 inflation device
and 3-way stopcockAC3200 1 each Everest20 Survival Kit: - Everest20 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC2205P 1 each Everest30 Survival Kit: - Everest30 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC3205P 1 each ACCESSORIES ORDERING INFORMATION
Metal guidewire insertion tool 006073 5 each Torque handle AC4006 5 each Piton⢠Y-Adapter with metal guidewire insertion tool AC4001M 5 each Piton⢠Tri-Adapter with metal guidewire insertion tool AC4002M 5 each Piton⢠Y-Adapter with metal guidewire insertion tool and torque handle AC4003M 5 each -
OCTOPUS TISSUE STABILIZER
OctopusĀ
TissueĀ Stabilizers
OCTOPUS TISSUEĀ STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS ā THE NEXT GENERATION TISSUEĀ STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus⢠Evolution ā enhanced stability, flexibility, and a lower profile for unlimited positioning options ā the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximumĀ stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION ā LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizerĀ provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows ātoes upā position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 ā EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement
-
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance⢠aspiration catheter delivers consistent, high-performing aspiration power when it matters most ā restoring flow and protecting patients.
PRODUCT DETAILSā
Superior Deliverability1
Full-Wall TechnologyĀ provides variable levels of stiffness without joints, for optimalĀ kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffnessĀ during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibilityĀ allows for extra support, when needed.ā
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.ā”
- Optimised hub geometry improves flow.ā”
- Soft, short, forward-facing tip design permits excellent particle capture.ā
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ā¢Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export⢠AP catheter.
- Bench testing vs. Terumo Eliminateā¢* and Eliminateā¢* 3 aspiration catheters, Vascular Solutions ProntoĀ®*Ā LP, ProntoĀ®*Ā V3 and ProntoĀ®*Ā V4 aspiration catheters, MeritĀ®*Ā ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCatā¢* aspiration catheter, IHT Polska HunterĀ®* aspiration catheter, Medrad Possisā¢* Fetchā¢* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export⢠AP aspiration catheter without stylet.










Reviews
There are no reviews yet.