ARTHO SCOPY PUNCH
n an endeavour to give our clients customized range of Arthroscopic Punch, we work as per their specific requirements. Our offered Arthroscopic Punch t is perfectly stitched and gives ease to the user. Our products ranges are manufactured using the supreme quality of raw material in compliance with the set industrial norms.
Features:
- Sturdy
- Rust resistance
- Price effective
Related products
-
Launcher- 6f Guiding Catheter’s
EBU@ (Extra Backup)
LA6EBU30 (EBU 3.0)
LA6EBU35 (EBU 3.5)
LA6EBU375 (EBU 3.75)
LA6EBU40 (EBU 4.0)
LA6EBU45 (EBU 4.5)
LA6EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA6JL30 (JL 3.0)
LA6JL35 (JL 3.5)
LA6JL40 (JL 4.0)
LA6JL45 (JL 4.5)
LA6JL50 (JL 5.0)
LA6JL60 (JL 6.0)
JR@ (Judkin Right )
LA6JR30 (JR 3.0)
LA6JR35 (JR 3.5)
LA6JR40 (JR 4.0)
LA6JR45 (JR 4.5)
LA6JR50 (JR 5.0)
LA6JR60 (JR 6.0)
AL@ (Amplatz Left )
LA6AL75 (AL .75)
LA6AL10 (AL 1.0)
LA6AL15 (AL 1.5)
LA6AL20 (AL 2.0)
LA6AL25 (AL 2.5)
LA6AL30 (AL 3.0)
LA6AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA6SAL75 (SAL . 75)
LA6SAL10 (SAL 1.0)
LA6SAL15 (SAL 1.5)
LA6SAL20 (SAL 2.0)
LA6SAL25 (SAL 2.5)
LA6SAL30 (SAL 3.0)
LA6SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA6AR10 (AR 1.0)
LA6AR20 (AR 2.0)
LA6ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA6ECR35 (ECR 3.5)
LA6ECR40 (ECR 4.0)
LA6ECR45 (ECR 4.5)
LA6RBU35 (RBU 3.5)
LA6RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA6SCR35 (SCR 3.5)
LA6SCR40 (SCR 4.0)
LA6SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA6SAR10 (SAR 1.0)
LA6SAR20 (SAR 2.0)
Multipurpose@
LA6MB1 (MB 1)
LA6MB2 (MB 2)
LA6HSREL (Hockey Stick)
LA6HSI (Hockey I)
LA6HSII (Hockey II)
LA6HSIII (Hockey III)
Bypass Crafts@
LA6LCB (LCB)
LA6RCB (RCB)
LA6RCB (RCB III)
LA6RCB (RCBÂ 90cm)
LA6IMA (IMA)
LA6IMA (IMAÂ 90cm)
-
ACT CARTRIDGE (HR-ACT)
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
SKU:402-03Weight:3.00 LBSAvailability:2-3 Business daysShipping:Calculated at checkoutQuantity:Product Description
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50Â
                   ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box 402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box 402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box 402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box -
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryureiâ„¢ has superior crossability1Â thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1Â results in enhanced trackability1Â while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part, tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distal low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
​Shaft diameter ​1.9 Fr/0.64 mm Proximal • 2.5 Fr/0.84 mm Middle • 2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) • 2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) ​Usable length ​145 cm ​Balloon markers # ​1(Ø1.0 to Ø 1.5 mm) • 2(Ø2.0 to Ø4.0 mm) ​Nominal pressure ​6 atm / 608 kPa ​Rated burst pressure Ø1.0 – 3.0 mm=14 atm(1419kPa) • Ø3.25 – 4.0 mm = 12 atm(1216 kPa) ​Guidewire compatibility ​Maximum diameter: 0.014″ / 0.36 mm ​Lesion entry profile ​0.41 mm (Ø1.00 to Ø1.50 mm) • 0.43 mm (Ø2.00 to Ø4.00 mm) ​Coating ​Hydrophilic Item specifications
Balloon length / Product code​​ ​ ​ ​ ​ ​
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH ​1.25 mm ​DC-RR1205HH ​​DC-RR1210HH ​​DC-RR1215HH ​​DC-RR1220HH ​ ​ 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1 Ryurei φ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ø 1.00 mm – Ø 1.50 mm.
** For Ryurei Ø 1.00mm – 5mm ​2 Compared to Tazuna PTCA dilatation catheter
-
SPRINTER LEGEND PTCA BALLOON
SPRINTER LEGEND 1.25 BALLOON CATHETER
Super Crosser Semi compliant Balloon Dilatation Catheter (RX/OTW)
Sprinter™ Legend™ 1.25 SuperCrosser semicompliant balloon dilatation catheter delivers exceptional crossability to treat today’s challenging lesions.
With innovative crossing technologies and 57 sizes, the Sprinter™ Legend™ RX semicompliant balloon dilatation catheter provides you with the power to cross.
OVERVIEW
During difficult cases, reach for a slim Sprinterâ„¢ Legendâ„¢ 1.25 mm Super Crosser semi compliant coronary balloon catheter featuring:
- Award-winning* Zerofold technology — no wrapped material and no balloon shoulders
- Low 0.5 mm (0.020 in) crossing profile
- OTW and RX platforms
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
1.25 SPL12506WL SPL12510WL SPL12515WL SPL12520WL Sprinter Legend RX Semi compliant
Balloon Dilatation Catheter
OVERVIEW
Performance You Can Trust
Sprinterâ„¢ Legendâ„¢ semicompliant balloons help you cross, open, and treat lesions during challenging percutaneous coronary interventions (PCIs), and feature:
- Some of the industry’s lowest crossing profiles1
- Innovative crossing technology
- A broad range of sizes
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
Balloon Diameter (mm)
1.25 SPL12506X SPL12510X SPL12512X SPL12515X 1.50 SPL15006X SPL15010X SPL15012X SPL15015X 2.00 SPL20006X SPL20010X SPL20012X SPL20015X 2.25 SPL22506X SPL22510X SPL22512X SPL22515X 2.50 SPL25006X SPL25010X SPL25012X SPL25015X 2.75 SPL27506X — SPL27512X SPL27515X 3.00 SPL30006X SPL30010X SPL30012X SPL30015X 3.25 — — SPL32512X SPL32515X 3.50 SPL35006X SPL35010X SPL35012X SPL35015X 3.75 — — SPL37512X SPL37515X 4.00 SPL40006X SPL40010X SPL40012X SPL40015X BALLOON LENGTHS 20, 25, AND 30 MM
Balloon Diameter (mm)
1.25 SPL12520X — — 1.50 SPL15020X — — 2.00 SPL20020X SPL20025X SPL20030X 2.25 SPL22520X SPL22525X — 2.50 SPL25020X SPL25025X SPL25030X 2.75 SPL27520X SPL27525X — 3.00 SPL30020X SPL30025X SPL30030X 3.25 SPL32520X — — 3.50 SPL35020X SPL35025X SPL35030X 3.75 SPL37520X — — 4.00 SPL40020X SPL40025X SPL40030X









Quiernera –
Unlove pfBLfgnDwCKWwRl 6 19 2022 [url=https://fastpriligy.top/]can you buy priligy online[/url] Maybe mucus issues