“AFFINITY FUSION Oxygenation System”
AFFINITY FUSION™
Oxygenation System
OVERVIEW
DESIGNED BY PERFUSIONISTS. ENGINEERED BY MEDTRONIC.
The Affinity Fusion™ oxygenation system’s design is based on input from more than 500 perfusionists worldwide. Thoughtfully engineered from inlet to outlet, the Affinity Fusion™ oxygenation system takes a fundamentally different design approach:
- Proactive air handling
- Haemocompatibility
- Improved flexibility
- Integrated arterial filter
- Expanded heat exchanger and gas transfer capabilities
PRODUCT DETAILS: AFFINITY FUSION™ OXYGENATION SYSTEM
Both oxygenator and reservoir device have:
- Blood-contacting materials made from BPA* – and DEHP-free polymers
- 1 to 7 L/min flow rate
- Low system priming volume
- Biocompatible surface coatings
Oxygenator available in:
- Balance™ biosurface coating
- Cortiva™ bioactive surface
Cardiotomy/venous reservoir available in:
- Balance™ biosurface coating
PET HEAT EXCHANGER
SAFE. EFFECTIVE. ENVIRONMENTALLY FRIENDLY.
The higher density structure of the Affinity Fusion™ polyethylene terephthalate (PET) heat exchanger provides improved chemical resistance with a low permeability factor when compared to lower density plastics such as polyurethane or TPU*.
PET heat exchanger features and benefits:
- Resistant to chemical migration
- Durable to withstand the surrounding environment
- Small tube design of capillaries increases heat exchange performance
- Decreases prime volume
- Enables device incineration
| Oxygenator Features | Cardiotomy/Venous Reservoir Features |
|---|---|
|
|
AFFINITY FUSION™ OXYGENATION SYSTEM SPECIFICATIONS
OXYGENATOR
| Membrane type | Microporous polypropylene hollow fiber |
| Membrane surface area | 2.5m2 |
| Heat exchange surface material | Polyethylene terephthalate (PET) |
| Static priming volume | 260 mL |
| Recommended blood flow rate | 1-7 L/min |
| Maximum water side pressure | 30 psi |
| Maximum blood pressure | 750 mm Hg |
| Arterial outlet port | 3/8″ |
| Venous inlet port | 3/8″ |
| Arterial sample port | Female luer port |
| Recirculation port | 1/4″ |
| Cardioplegia port | 1/4″ |
| Gas inlet port | 1/4″ nonbarbed |
| Gas outlet port | 3/8″ nonbarbed |
| Water ports | 1/2″ quick disconnects |
| Filtration | 25 µm |
CARDIOTOMY/VENOUS RESERVOIR
| Reservoir volume capacity | 4500 ml |
| Recommended blood flow rate | 1-7 L/min |
| Maximum cardiotomy flow rate | 6 L/min |
| Minimum operating level | 200 mL at 7L/min |
| Cardiotomy filtration | 30 µm |
| Venous screen | 105 µm |
| Venous inlet, rotatable | 1/2″ with 3/8″ adapter |
| Venous reservoir outlet | 3/8″ |
| Vent/VAVD port | 1/4″ nonbarbed |
| Cardiotomy port (4) | 1/4″ |
| Cardiotomy port (1) | 3/8″ |
| Prime port | 1/4″ nonbarbed |
| Recirculation port | 1/4″ |
| Filtered luer lock ports | 4 |
| Non-filtered luer lock ports | 2 |
| Venous luer lock ports | 2 |
| Positive pressure relief valve crack | <5 mm Hg |
| Vacuum pressure relief valve crack |
|
ORDERING INFORMATION
| Affinity Fusion™ Oxygenation Systems | ||
|---|---|---|
| Model# | Product Description | Units/case |
| CB841 | Oxygenator with integrated arterial filter with Cortiva bioactive surface and cardiotomy/venous reservoir with Balance biosurface | 1 |
| BB841 | Oxygenator with integrated arterial filter and cardiotomy/venous reservoir with Balance biosurface | 1
|
| CB811 | Oxygenator with integrated arterial filter and Cortiva bioactive surface | 1 |
| BB811 | Oxygenator with integrated arterial filter and Balance biosurface | 1 |
| Affinity Fusion™ Accessories and Holders | ||
| Model # | Product Description | Units/Case |
| AUH2093 | Affinity™ orbit holder system | 1 |
| ATP210 | Temperature probe | 1 |
| AMH2014 | Affinity™ manifold holder | 1 |
| RCL841 | Recirculation line | 12 |
MANUALS AND TECHNICAL GUIDES
Instructions for Use
Find this technical manual in the product labeling supplied with each device.
“AFFINITY FUSION Oxygenation System”
1 review for “AFFINITY FUSION Oxygenation System”
Related products
-
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.
-
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technology where the outside diameter is reduced by one French size while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumo’s proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumo’s proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Association’s identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGY™: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.
-
RADIFOCUS INTRODUCER SHEATH
Radifocus™ Introducer II Standard Kit A
Introducer Sheath (FEMORAL)
Kit of vascular introducer with hemostatic valve with excellent blood tightness,
easy and non traumatic vessel insertion, patented valve design for a unique
features package.- Total Integrated Fit (TIF) tip tapering: tapering design at the tip of the sheath and dilator to facilitate smooth penetration
- Cross-cut hemostasis valve to avoid blood reflux and air aspiration
- Thin radiopaque sheath with anti-kinking sleeve for easy catheter handling
- Snap-on/click-off dilator lock prevents dilator back-out during insertion and allows one-hand unlocking
- Wide variety of kit variations providing all elements for quick vessel access: 4-11 Fr sheaths, 5-16 cm lengths, Surf lash needle
General specifications
Sheath length 10 cm Mini guidewire Plastic Straight and Angled
0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type; 0.035″ (0.89 mm) for all others
45 cmEntry needle Plastic IV Catheter – 18G x 2 ½” (1.2 x 64 mm),
except for 4 Fr with 45 cm straight mini guidewire: 20G x 2″ (0.9 x 51 mm)
2.5 ml syringe is includedGuidewire compatibility 0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type
0.035″ (0.89 mm) for all othersPackaging Tray A Kit content Sheath, dilator, plastic mini guidewire and plastic IV catheter (entry needle) Item specifications
Inner diameter Mini guidewire type 45 cm angled 45 cm straight 4 Fr RS+A40K10AQ RS+A40G10SQ 4 Fr RS*A40G10SQ RS*A40G05SQ 4 Fr RS*A40K10SQ RS*A40G07SQ 5 Fr RS*A50K10AQ RS*A50G07SQ 5 Fr RS+A50K10AQ RS+A50K10SQ 6 Fr RS+A60K10AQ RS+A60K10SQ 6 Fr RS*A60K10AQ RS*A60G07SQ 6 Fr — RS*A60G16SQZ 6 Fr — RS*A60K10SQ 6 Fr — RS+A50K10SQ 7 Fr — RS+A70K10SQ 7 Fr — RS*A70G07SQ 7 Fr — RS*A70K10SQ 8 Fr — RS+A80K10SQ 8 Fr — RS*A80K10SQ 9 Fr — RS*A90K10SQ 10 Fr — RS*A10K10SQ 11 Fr — RS*A11K10SQ A Kit includes: introducer sheath, dilator, mini Guide wire, entry venous catheter, 2.5 cc syringe
B Kit includes: introducer sheath, dilator, mini Guide wire
C Kit includes: introducer sheath, dilator
R Kit includes: introducer sheath, dilator, mini Guide wire, 18 G x 2 3/4” / 1.2 x 70 mm entry metallic needle
Other code numbers are available on special demand. For any further information, please contact your Terumo local representative
Units per box: 5 for kits in tray and 10 for kits in pouch. -
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILS†
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.†
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.†
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ™Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export™ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export™ AP aspiration catheter without stylet.









Quiernera –
buying priligy online Children Above Eight Years of Age