ACT MACHINE
ACT PLUS AUTOMATED COAGULATION TIMER
SYSTEM
Precise, Reliable – The Trusted Standard
BLOOD DIAGNOSTICS AND CLOT DETECTION
In addition to running cardiopulmonary bypass, we know that you rely on accurate blood diagnostic results.
The ACT Plus® System combines a trusted standard in precise clot detection technology with state-of-the-art user features including data management and connectivity-ready capabilities. It is a microprocessor-controlled electromechanical coagulation instrument designed to determine coagulation endpoints in fresh and citrated whole blood samples. Clotting-time results are presented on the instrument’s Clot Time Display (CTD) and Liquid Crystal Display (LCD) screens.
The ACT Plus System provides long-term data storage and retrieval, with access to previous patient and quality control test data. Test results are stored in the order in which they are performed. The ability to externally transfer or save data enhances the system’s versatility.
The ACT Plus System is portable and well suited for all point-of-care testing situations. It offers the reliability required in:
Cardiovascular and vascular surgery
ECMO
Cardiac catheterization laboratories
Critical care units
Hemodialysis units
MANAGE YOUR ACT PLUS SYSTEM DATA EFFICIENTLY AND EFFECTIVELY
As part of our ongoing commitment to helping you manage your work efficiently and effectively, we offer the ACT Plus EDM external data manager to accompany the ACT Plus Automated Coagulation Timer System.
By combining this powerful software with the ACT Plus System, you will have access to the reports you’ll need to analyze test results and make informed decisions. This timesaving data management solution offers added convenience, reassurance and confidence—allowing you to stay focused on improving patient outcomes.
The ACT Plus EDM is a versatile Microsoft Access-based data management software application that runs on a PC and is designed to help you manage your patient, QC, instrument and user ID data. All aspects of Microsoft Access software required to run the application are included with the ACT Plus EDM.
| ACT Plus Instrument | ||
|---|---|---|
| Order Number | Description | # of Units |
| ACT100 | ACT Plus System is a microprocessor-controlled electromechanical coagulation instrument for determination of activated coagulation times | 1 per box |
| ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges | ||
|---|---|---|
| 402-01 | Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis | 50 per box |
| 402-02 | Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL | 50 per box |
| 402-03 | High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery | 50 per box |
| 402-07 | Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample | 20 per box |
| ACT® CLOTtrac® Coagulation Controls | ||
|---|---|---|
| 550-01 | CLOTtrac CWB Coagulation Control – Verify performance of 402-01 and 402-02 cartridges, and the ACT Plus Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac CWB coagulation control) | 15 per box |
| 550-07 | CLOTtrac HR Coagulation Control – Verify performance of 402-03, and 402-07 cartridges and the ACT Plus Instrument | 15 per box |
| 550-08 | CLOTtrac HR Abnormal Coagulation Control – Verify performance of 402-03 cartridges and the ACT Plus Instrument | 15 per box |
| 550-09 | CLOTtrac LR Abnormal Coagulation Control – Verify performance of 402-01 cartridges and the ACT Plus® Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac LR abnormal coagulation control) | 15 per box |
| 550-10 | CLOTtrac RACT Abnormal Coagulation Control – Verify performance of 402-02 cartridges and the ACT Plus® Instrument | 15 per box |
| 550-12 | CLOTtrac HTC Coagulation Control – Verify performance of 402-07 cartridges and the ACT Plus® Instrument | 15 per box |
| 550-13 | CLOTtrac HR Control Pack – Verify performance of 402-03 cartridges and the ACT Plus Instrument (contains 15 HR Normal and 15 HR Abnormal) | 15 per box |
| 550-11 | Calcium Chloride 5 ml vial – Use with control nos. 550-01, 550-09 in cartridge 402-01 | 15 per box |
3 reviews for ACT MACHINE
Related products
-
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS
-
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILSâ€
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.â€
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.â€
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - â„¢Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Exportâ„¢ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Exportâ„¢ AP aspiration catheter without stylet.
-
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryureiâ„¢ has superior crossability1Â thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1Â results in enhanced trackability1Â while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part, tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distal low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
​Shaft diameter ​1.9 Fr/0.64 mm Proximal • 2.5 Fr/0.84 mm Middle • 2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) • 2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) ​Usable length ​145 cm ​Balloon markers # ​1(Ø1.0 to Ø 1.5 mm) • 2(Ø2.0 to Ø4.0 mm) ​Nominal pressure ​6 atm / 608 kPa ​Rated burst pressure Ø1.0 – 3.0 mm=14 atm(1419kPa) • Ø3.25 – 4.0 mm = 12 atm(1216 kPa) ​Guidewire compatibility ​Maximum diameter: 0.014″ / 0.36 mm ​Lesion entry profile ​0.41 mm (Ø1.00 to Ø1.50 mm) • 0.43 mm (Ø2.00 to Ø4.00 mm) ​Coating ​Hydrophilic Item specifications
Balloon length / Product code​​ ​ ​ ​ ​ ​
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH ​1.25 mm ​DC-RR1205HH ​​DC-RR1210HH ​​DC-RR1215HH ​​DC-RR1220HH ​ ​ 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1 Ryurei φ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ø 1.00 mm – Ø 1.50 mm.
** For Ryurei Ø 1.00mm – 5mm ​2 Compared to Tazuna PTCA dilatation catheter
-
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technology where the outside diameter is reduced by one French size while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumo’s proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumo’s proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Association’s identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGYâ„¢: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.









https://bandur-art.blogspot.com/2024/08/the-ultimate-guide-to-no-mans-sky-mods.html –
We’re a group of volunteers and starting a new scheme in our community.
Your site provided us with valuable information too work
on. You’ve done an impressive jjob and our entire community will be grateful to you. https://bandur-art.blogspot.com/2024/08/the-ultimate-guide-to-no-mans-sky-mods.html
Quiernera –
The amplitude and latency of these ERP polarity peaks are thought to reflect the strength and timing of cognitive processes, suggesting that adult loss of CDKL5 also impairs sensory information processing in conjunction with compromised behavioral functions buy priligy online
Dichaelsok –
Hey! Do you know if they make any plugins to assist with SEO? I’m trying to get my blog to rank for some targeted keywords but I’m not seeing very good success. If you know of any please share. Thanks!
https://rainbetaustralia.com/