TECHNICAL INFORMATION
| NC TREK™ CORONARY DILATATION CATHETER | |
|---|---|
| NOMINAL PRESSURE (NP) | 12 atm |
| RATED BURST PRESSURE (RBP) | 18 atm |
| TIP ENTRY PROFILE | 0.020 in average (3.00 mm Ø) 0.022 in maximum (1.50 mm – 3.25 mm Ø) 0.024 in maximum (3.50 mm – 5.00 mm Ø) |
| CROSSING PROFILE | 0.027 in average (3.00 mm Ø) 0.032 in maximum (1.50 – 3.50 mm Ø) 0.037 in maximum (3.75 – 5.00 mm Ø) |
| RX NOTCH DIAMETER | 2.6 French average (3.00 mm Ø) 2.9 French maximum |
| TIP LENGTH | 3.5 +/- 0.5 mm (2.00 – 3.25 mm Ø) 4.5 +/- 0.5 mm (3.50 – 4.50 mm Ø) |
| BALLOON MATERIAL | Pebax‡, non-compliant |
| MARKER MATERIAL | Flexible Tungsten/Pebax‡ |
| SHAFT LENGTH | 143 cm |
| COATING | Hydrophilic |
| MAXIMUM GUIDE WIRE COMPATIBILITY | 0.014 in |
| LATEX FREE | Yes |

ORDERING INFORMATION
Broad Size Matrix with 59 Sizes Available
| BALLOON DIAMETER (MM) |
BALLOON LENGTH (MM) | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | ||
| NC TREK™ RX |
1.50 | 1012444-06 | 1012444-08 | 1012444-12 | 1012444-15 | 1012444-20 | – |
| 2.00 | 1012445-06 | 1012445-08 | 1012445-12 | 1012445-15 | 1012445-20 | – | |
| 2.25 | 1012446-06 | 1012446-08 | 1012446-12 | 1012446-15 | 1012446-20 | – | |
| 2.50 | 1012447-06 | 1012447-08 | 1012447-12 | 1012447-15 | 1012447-20 | 1012447-25 | |
| 2.75 | 1012448-06 | 1012448-08 | 1012448-12 | 1012448-15 | 1012448-20 | – | |
| 3.00 | 1012449-06 | 1012449-08 | 1012449-12 | 1012449-15 | 1012449-20 | 1012449-25 | |
| 3.25 | 1012450-06 | 1012450-08 | 1012450-12 | 1012450-15 | 1012450-20 | – | |
| 3.50 | 1012451-06 | 1012451-08 | 1012451-12 | 1012451-15 | 1012451-20 | 1012451-25 | |
| 3.75 | – | 1012452-08 | 1012452-12 | 1012452-15 | 1012452-20 | – | |
| 4.00 | – | 1012453-08 | 1012453-12 | 1012453-15 | 1012453-20 | – | |
| 4.50 | – | 1012454-08 | 1012454-12 | 1012454-15 | 1012454-20 | – | |
| 5.00 | – | 1012455-08 | 1012455-12 | 1012455-15 | 1012455-20 | – | |
COMPLIANCE CHART
| INFLATION PRESSURE (ATM) |
BALLOON DIAMETER (MM) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 | 2.00 | 2.25 | 2.50 | 2.75 | 3.00 | 3.25 | 3.50 | 3.75 | 4.00 | 4.50 | 5.00 | |
| 2 | 1.36 | 1.75 | 1.97 | 2.11 | 2.34 | 2.52 | 2.74 | 2.99 | 3.21 | 3.35 | 3.76 | 4.25 |
| 3 | 1.37 | 1.78 | 1.99 | 2.19 | 2.38 | 2.58 | 2.84 | 3.05 | 3.29 | 3.45 | 3.87 | 4.35 |
| 4 | 1.38 | 1.81 | 2.02 | 2.22 | 2.43 | 2.63 | 2.89 | 3.11 | 3.35 | 3.52 | 3.93 | 4.43 |
| 5 | 1.39 | 1.84 | 2.04 | 2.26 | 2.47 | 2.68 | 2.95 | 3.18 | 3.41 | 3.59 | 3.99 | 4.50 |
| 6 | 1.41 | 1.87 | 2.09 | 2.30 | 2.51 | 2.73 | 3.01 | 3.23 | 3.47 | 3.65 | 4.06 | 4.58 |
| 7 | 1.42 | 1.90 | 2.13 | 2.34 | 2.55 | 2.78 | 3.06 | 3.29 | 3.53 | 3.71 | 4.13 | 4.66 |
| 8 | 1.43 | 1.93 | 2.16 | 2.38 | 2.58 | 2.83 | 3.10 | 3.34 | 3.59 | 3.77 | 4.20 | 4.73 |
| 9 | 1.45 | 1.95 | 2.19 | 2.42 | 2.63 | 2.87 | 3.15 | 3.37 | 3.63 | 3.83 | 4.26 | 4.80 |
| 10 | 1.46 | 1.98 | 2.22 | 2.45 | 2.66 | 2.91 | 3.16 | 3.42 | 3.67 | 3.87 | 4.32 | 4.86 |
| 11 | 1.47 | 2.00 | 2.24 | 2.48 | 2.69 | 2.94 | 3.23 | 3.46 | 3.71 | 3.91 | 4.37 | 4.91 |
| 12 NP | 1.49 | 2.01 | 2.26 | 2.50 | 2.71 | 2.97 | 3.26 | 3.49 | 3.74 | 3.95 | 4.41 | 4.96 |
| 13 | 1.50 | 2.03 | 2.28 | 2.53 | 2.73 | 3.00 | 3.28 | 3.51 | 3.77 | 3.98 | 4.45 | 5.00 |
| 14 | 1.51 | 2.04 | 2.30 | 2.55 | 2.76 | 3.02 | 3.31 | 3.54 | 3.80 | 4.01 | 4.49 | 5.04 |
| 15 | 1.52 | 2.06 | 2.32 | 2.57 | 2.78 | 3.04 | 3.34 | 3.57 | 3.82 | 4.04 | 4.53 | 5.08 |
| 16 | 1.53 | 2.07 | 2.33 | 2.59 | 2.79 | 3.07 | 3.36 | 3.60 | 3.85 | 4.07 | 4.57 | 5.12 |
| 17 | 1.53 | 2.09 | 2.35 | 2.62 | 2.82 | 3.09 | 3.39 | 3.62 | 3.88 | 4.10 | 4.60 | 5.16 |
| 18 RBP | 1.54 | 2.10 | 2.37 | 2.64 | 2.84 | 3.11 | 3.41 | 3.65 | 3.91 | 4.13 | 4.64 | 5.20 |
| 19 | 1.55 | 2.12 | 2.39 | 2.67 | 2.86 | 3.14 | 3.44 | 3.68 | 3.93 | 4.16 | 4.68 | 5.24 |
| 20 | 1.56 | 2.13 | 2.41 | 2.69 | 2.88 | 3.16 | 3.47 | 3.71 | 3.96 | 4.19 | 4.72 | 5.28 |
| 21 | 1.57 | 2.15 | 2.42 | 2.72 | 2.90 | 3.18 | 3.50 | 3.75 | – | 4.22 | 4.76 | 5.33 |
| 22 | 1.58 | 2.17 | 2.45 | 2.75 | 2.93 | 3.21 | – | 3.78 | – | 4.25 | – | 5.37 |
Related products
-
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILS†
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.†
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.†
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ™Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export™ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export™ AP aspiration catheter without stylet.
-
NC Sprinter PTCA BALLOON
NC Sprinter RX Noncompliant
NC Stormer over-the-wire noncompliant balloon dilatation catheter offers controlled compliance, high pressures, and comprehensive lengths.
Balloon Dilatation Catheter
OVERVIEW
The NC Sprinter™ RX noncompliant coronary balloon combines:
- Sprinter crossing technology
- High-pressure capability and controlled expansion1
ORDERING INFORMATION
BALLOON LENGTHS 6, 9, 12 MM
Balloon Diameter (mm)
Balloon Length (mm) 6 9 12 2.00 NCSP2006X NCSP2009X NCSP2012X 2.25 NCSP22506X — NCSP22512X 2.50 NCSP2506X NCSP2509X NCSP2512X 2.75 NCSP27506X NCSP27509X NCSP27512X 3.00 NCSP3006X NCSP3009X NCSP3012X 3.25 NCSP32506X NCSP32509X NCSP32512X 3.50 NCSP3506X NCSP3509X NCSP3512X 3.75 NCSP37506X NCSP37509X NCSP37512X 4.00 NCSP4006X NCSP4009X NCSP4012X 4.50 — — — 5.00 — — — BALLOON LENGTHS 15, 21, 27 MM
Balloon Diameter (mm)
Balloon Length (mm) 15 21 27 2.00 NCSP2015X NCSP2021X — 2.25 — NCSP22521X — 2.50 NCSP2515X NCSP2521X NCSP2527X 2.75 NCSP27515X NCSP27521X — 3.00 NCSP3015X NCSP3021X NCSP3027X 3.25 NCSP32515X NCSP32521X — 3.50 NCSP3515X NCSP3521X NCSP3527X 3.75 NCSP37515X NCSP37521X — 4.00 NCSP4015X NCSP4021X NCSP4027X 4.50 NCSP4515X NCSP4521X — 5.00 NCSP5015X — — -
RADIFOCUS INTRODUCER SHEATH
Radifocus™ Introducer II Standard Kit A
Introducer Sheath (FEMORAL)
Kit of vascular introducer with hemostatic valve with excellent blood tightness,
easy and non traumatic vessel insertion, patented valve design for a unique
features package.- Total Integrated Fit (TIF) tip tapering: tapering design at the tip of the sheath and dilator to facilitate smooth penetration
- Cross-cut hemostasis valve to avoid blood reflux and air aspiration
- Thin radiopaque sheath with anti-kinking sleeve for easy catheter handling
- Snap-on/click-off dilator lock prevents dilator back-out during insertion and allows one-hand unlocking
- Wide variety of kit variations providing all elements for quick vessel access: 4-11 Fr sheaths, 5-16 cm lengths, Surf lash needle
General specifications
Sheath length 10 cm Mini guidewire Plastic Straight and Angled
0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type; 0.035″ (0.89 mm) for all others
45 cmEntry needle Plastic IV Catheter – 18G x 2 ½” (1.2 x 64 mm),
except for 4 Fr with 45 cm straight mini guidewire: 20G x 2″ (0.9 x 51 mm)
2.5 ml syringe is includedGuidewire compatibility 0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type
0.035″ (0.89 mm) for all othersPackaging Tray A Kit content Sheath, dilator, plastic mini guidewire and plastic IV catheter (entry needle) Item specifications
Inner diameter Mini guidewire type 45 cm angled 45 cm straight 4 Fr RS+A40K10AQ RS+A40G10SQ 4 Fr RS*A40G10SQ RS*A40G05SQ 4 Fr RS*A40K10SQ RS*A40G07SQ 5 Fr RS*A50K10AQ RS*A50G07SQ 5 Fr RS+A50K10AQ RS+A50K10SQ 6 Fr RS+A60K10AQ RS+A60K10SQ 6 Fr RS*A60K10AQ RS*A60G07SQ 6 Fr — RS*A60G16SQZ 6 Fr — RS*A60K10SQ 6 Fr — RS+A50K10SQ 7 Fr — RS+A70K10SQ 7 Fr — RS*A70G07SQ 7 Fr — RS*A70K10SQ 8 Fr — RS+A80K10SQ 8 Fr — RS*A80K10SQ 9 Fr — RS*A90K10SQ 10 Fr — RS*A10K10SQ 11 Fr — RS*A11K10SQ A Kit includes: introducer sheath, dilator, mini Guide wire, entry venous catheter, 2.5 cc syringe
B Kit includes: introducer sheath, dilator, mini Guide wire
C Kit includes: introducer sheath, dilator
R Kit includes: introducer sheath, dilator, mini Guide wire, 18 G x 2 3/4” / 1.2 x 70 mm entry metallic needle
Other code numbers are available on special demand. For any further information, please contact your Terumo local representative
Units per box: 5 for kits in tray and 10 for kits in pouch. -
Everest30 INFLATION DEVICE
Everest 30
Disposable Inflation Device
OVERVIEW
Easy-to-use Rapid Inflation/Deflation Device
A simple solution for coronary balloon inflation. The Everest disposable inflation device features a quick trigger release and ergonomic pistol grip for ease of use. Plus, it’s available in your choice of 20 atm or 30 atm pressure gauge, and as a standalone or in a packaged kit.
PRODUCT DETAILS
The Everest Device Features:
- Quick trigger release so you can release pressure immediately, even at higher pressures
- Sure-grip torque knob with a ridged design for “no slip” torque control and precise pressure adjustment
- Unique ergonomic pistol grip with centered trigger that fits comfortably in either hand
- Luminescent dial face that provides accurate readability in normal and low-light conditions
EVEREST DISPOSABLE INFLATION DEVICE ORDERING INFORMATION
Disposable Inflation Device@ AC3200
Survival Kit Inflation Device@ AC305P
Everest20 inflation device
and 3-way stopcockAC2200 1 each Everest30 inflation device
and 3-way stopcockAC3200 1 each Everest20 Survival Kit: - Everest20 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC2205P 1 each Everest30 Survival Kit: - Everest30 inflation device
- 3-way stopcock
- Piton Y-Adapter
- Metal guidewire insertion tool
- Torque handle
AC3205P 1 each ACCESSORIES ORDERING INFORMATION
Metal guidewire insertion tool 006073 5 each Torque handle AC4006 5 each Piton™ Y-Adapter with metal guidewire insertion tool AC4001M 5 each Piton™ Tri-Adapter with metal guidewire insertion tool AC4002M 5 each Piton™ Y-Adapter with metal guidewire insertion tool and torque handle AC4003M 5 each