PTCA BALLOON NC TREK
DES with most extensive clinical evidence with 50,000 patients enrolled worldwide. Facilitates early healing by abluminal gradient coating and reduced drug dose. Bifurcation Excellence. Flexible stent design. Advanced shaft technology. Reliable delivery in TRI.
The safety and effectiveness of this PTCA balloon catheter for the treatment of in-stent restenosis (ISR) has not been established. Potential Adverse Events.
The RX NC Takeru PTCA Balloon Dilatation Catheter is indicated for balloon dilatation of the stenotic portion in the coronary artery or bypass graft stenosis.
47732 – Basic Coronary Angioplasty Balloon Catheter … MINI TREK RX Coronary Dilatation Catheters. Catalog Numbers. Balloon Length. 6mm 8mm 12mm 15mm.
TECHNICAL INFORMATION
| NC TREKâ„¢ CORONARY DILATATION CATHETER | |
|---|---|
| NOMINAL PRESSURE (NP) | 12 atm |
| RATED BURST PRESSURE (RBP) | 18 atm |
| TIP ENTRY PROFILE | 0.020 in average (3.00 mm Ø) 0.022 in maximum (1.50 mm – 3.25 mm Ø) 0.024 in maximum (3.50 mm – 5.00 mm Ø) |
| CROSSING PROFILE | 0.027 in average (3.00 mm Ø) 0.032 in maximum (1.50 – 3.50 mm Ø) 0.037 in maximum (3.75 – 5.00 mm Ø) |
| RX NOTCH DIAMETER | 2.6 French average (3.00 mm Ø) 2.9 French maximum |
| TIP LENGTH | 3.5 +/- 0.5 mm (2.00 – 3.25 mm Ø) 4.5 +/- 0.5 mm (3.50 – 4.50 mm Ø) |
| BALLOON MATERIAL | Pebax‡, non-compliant |
| MARKER MATERIAL | Flexible Tungsten/Pebax‡ |
| SHAFT LENGTH | 143 cm |
| COATING | Hydrophilic |
| MAXIMUM GUIDE WIRE COMPATIBILITY | 0.014 in |
| LATEX FREE | Yes |

ORDERING INFORMATION
Broad Size Matrix with 59 Sizes Available
| BALLOON DIAMETER (MM) |
BALLOON LENGTH (MM) | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | ||
| NC TREKâ„¢ RX |
1.50 | 1012444-06 | 1012444-08 | 1012444-12 | 1012444-15 | 1012444-20 | – |
| 2.00 | 1012445-06 | 1012445-08 | 1012445-12 | 1012445-15 | 1012445-20 | – | |
| 2.25 | 1012446-06 | 1012446-08 | 1012446-12 | 1012446-15 | 1012446-20 | – | |
| 2.50 | 1012447-06 | 1012447-08 | 1012447-12 | 1012447-15 | 1012447-20 | 1012447-25 | |
| 2.75 | 1012448-06 | 1012448-08 | 1012448-12 | 1012448-15 | 1012448-20 | – | |
| 3.00 | 1012449-06 | 1012449-08 | 1012449-12 | 1012449-15 | 1012449-20 | 1012449-25 | |
| 3.25 | 1012450-06 | 1012450-08 | 1012450-12 | 1012450-15 | 1012450-20 | – | |
| 3.50 | 1012451-06 | 1012451-08 | 1012451-12 | 1012451-15 | 1012451-20 | 1012451-25 | |
| 3.75 | – | 1012452-08 | 1012452-12 | 1012452-15 | 1012452-20 | – | |
| 4.00 | – | 1012453-08 | 1012453-12 | 1012453-15 | 1012453-20 | – | |
| 4.50 | – | 1012454-08 | 1012454-12 | 1012454-15 | 1012454-20 | – | |
| 5.00 | – | 1012455-08 | 1012455-12 | 1012455-15 | 1012455-20 | – | |
COMPLIANCE CHART
| INFLATION PRESSURE (ATM) |
BALLOON DIAMETER (MM) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 | 2.00 | 2.25 | 2.50 | 2.75 | 3.00 | 3.25 | 3.50 | 3.75 | 4.00 | 4.50 | 5.00 | |
| 2 | 1.36 | 1.75 | 1.97 | 2.11 | 2.34 | 2.52 | 2.74 | 2.99 | 3.21 | 3.35 | 3.76 | 4.25 |
| 3 | 1.37 | 1.78 | 1.99 | 2.19 | 2.38 | 2.58 | 2.84 | 3.05 | 3.29 | 3.45 | 3.87 | 4.35 |
| 4 | 1.38 | 1.81 | 2.02 | 2.22 | 2.43 | 2.63 | 2.89 | 3.11 | 3.35 | 3.52 | 3.93 | 4.43 |
| 5 | 1.39 | 1.84 | 2.04 | 2.26 | 2.47 | 2.68 | 2.95 | 3.18 | 3.41 | 3.59 | 3.99 | 4.50 |
| 6 | 1.41 | 1.87 | 2.09 | 2.30 | 2.51 | 2.73 | 3.01 | 3.23 | 3.47 | 3.65 | 4.06 | 4.58 |
| 7 | 1.42 | 1.90 | 2.13 | 2.34 | 2.55 | 2.78 | 3.06 | 3.29 | 3.53 | 3.71 | 4.13 | 4.66 |
| 8 | 1.43 | 1.93 | 2.16 | 2.38 | 2.58 | 2.83 | 3.10 | 3.34 | 3.59 | 3.77 | 4.20 | 4.73 |
| 9 | 1.45 | 1.95 | 2.19 | 2.42 | 2.63 | 2.87 | 3.15 | 3.37 | 3.63 | 3.83 | 4.26 | 4.80 |
| 10 | 1.46 | 1.98 | 2.22 | 2.45 | 2.66 | 2.91 | 3.16 | 3.42 | 3.67 | 3.87 | 4.32 | 4.86 |
| 11 | 1.47 | 2.00 | 2.24 | 2.48 | 2.69 | 2.94 | 3.23 | 3.46 | 3.71 | 3.91 | 4.37 | 4.91 |
| 12 NP | 1.49 | 2.01 | 2.26 | 2.50 | 2.71 | 2.97 | 3.26 | 3.49 | 3.74 | 3.95 | 4.41 | 4.96 |
| 13 | 1.50 | 2.03 | 2.28 | 2.53 | 2.73 | 3.00 | 3.28 | 3.51 | 3.77 | 3.98 | 4.45 | 5.00 |
| 14 | 1.51 | 2.04 | 2.30 | 2.55 | 2.76 | 3.02 | 3.31 | 3.54 | 3.80 | 4.01 | 4.49 | 5.04 |
| 15 | 1.52 | 2.06 | 2.32 | 2.57 | 2.78 | 3.04 | 3.34 | 3.57 | 3.82 | 4.04 | 4.53 | 5.08 |
| 16 | 1.53 | 2.07 | 2.33 | 2.59 | 2.79 | 3.07 | 3.36 | 3.60 | 3.85 | 4.07 | 4.57 | 5.12 |
| 17 | 1.53 | 2.09 | 2.35 | 2.62 | 2.82 | 3.09 | 3.39 | 3.62 | 3.88 | 4.10 | 4.60 | 5.16 |
| 18 RBP | 1.54 | 2.10 | 2.37 | 2.64 | 2.84 | 3.11 | 3.41 | 3.65 | 3.91 | 4.13 | 4.64 | 5.20 |
| 19 | 1.55 | 2.12 | 2.39 | 2.67 | 2.86 | 3.14 | 3.44 | 3.68 | 3.93 | 4.16 | 4.68 | 5.24 |
| 20 | 1.56 | 2.13 | 2.41 | 2.69 | 2.88 | 3.16 | 3.47 | 3.71 | 3.96 | 4.19 | 4.72 | 5.28 |
| 21 | 1.57 | 2.15 | 2.42 | 2.72 | 2.90 | 3.18 | 3.50 | 3.75 | – | 4.22 | 4.76 | 5.33 |
| 22 | 1.58 | 2.17 | 2.45 | 2.75 | 2.93 | 3.21 | – | 3.78 | – | 4.25 | – | 5.37 |
Related products
-
Sprinter OTW Balloon
Sprinter OTW Semicompliant
Balloon Dilatation Catheter
Sprinterâ„¢ over-the-wire semicompliant balloon offers low-tip and crossing profiles with a comprehensive size matrix
OVERVIEW
The Sprinterâ„¢ over-the-wire (OTW) semicompliant balloon dilatation catheter is available in a broad size matrix.
FEATURES
MiniWrap folding is used on 1.50-4.00 balloons. The 1.50 mm balloon has two folds.
- Â Selective Dura-Trac coating
- Â 2.5 mm tip
- Â FasTrac tip
Balloon’s
- Distal shaft
- Gold-swaged marker bands
- Selective Dura-Trac hydrophilic coating
- Fulcrum balloon material
- Proximal shaft (oval)
- FasTrac tip
-
Launcher- 7f Guiding Catheter’s
EBU@ (Extra Backup)
LA7EBU30 (EBU 3.0)
LA7EBU35 (EBU 3.5)
LA7EBU375 (EBU 3.75)
LA7EBU40 (EBU 4.0)
LA7EBU45 (EBU 4.5)
LA7EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA7JL30 (JL 3.0)
LA7JL35 (JL 3.5)
LA7JL40 (JL 4.0)
LA7JL45 (JL 4.5)
LA7JL50 (JL 5.0)
LA7JL60 (JL 6.0)
JR@ (Judkin Right )
LA7JR30 (JR 3.0)
LA7JR35 (JR 3.5)
LA7JR40 (JR 4.0)
LA7JR45 (JR 4.5)
LA7JR50 (JR 5.0)
LA7JR60 (JR 6.0)
AL@ (Amplatz Left )
LA7AL75 (AL .75)
LA7AL10 (AL 1.0)
LA7AL15 (AL 1.5)
LA7AL20 (AL 2.0)
LA7AL25 (AL 2.5)
LA7AL30 (AL 3.0)
LA7AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA7SAL75 (SAL . 75)
LA7SAL10 (SAL 1.0)
LA7SAL15 (SAL 1.5)
LA7SAL20 (SAL 2.0)
LA7SAL25 (SAL 2.5)
LA7SAL30 (SAL 3.0)
LA7SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA7AR10 (AR 1.0)
LA7AR20 (AR 2.0)
LA7ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA7ECR35 (ECR 3.5)
LA7ECR40 (ECR 4.0)
LA7ECR45 (ECR 4.5)
LA7RBU35 (RBU 3.5)
LA7RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA7SCR35 (SCR 3.5)
LA7SCR40 (SCR 4.0)
LA7SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA7SAR10 (SAR 1.0)
LA7SAR20 (SAR 2.0)
Multipurpose@
LA7MB1 (MB 1)
LA7MB2 (MB 2)
LA7HSREL (Hockey Stick)
LA7HSI (Hockey I)
LA7HSII (Hockey II)
LA7HSIII (Hockey III)
Bypass Crafts@
LA7LCB (LCB)
LA7RCB (RCB)
LA7RCB (RCB III)
LA7RCB (RCBÂ 90cm)
LA7IMA (IMA)
LA7IMA (IMAÂ 90cm)
-
PTCA Balloon Ryurei
Description
Confidence in your hands
Ryureiâ„¢ has superior crossability1Â thanks to the combination of low distal profiles and Terumo’s hydrophilic M coating. The short balloon bonding and reinforced shaft1Â results in enhanced trackability1Â while maintaining excellent pushability1.
These features can increase physician’s confidence in success even during complex procedures.
CharacteristicsExcellent Pusability
The combination of flexible distal part, tapered core wire on the midshaft and the thick proximal hypotube, results in smooth and balanced transition across the entire catheter for high transmission force, resulting in excellent pushability
Superior Crossability2
Thanks to the combination of distal low profiles and the Terumo hydrophilic M-Coat, Ryurei offers low friction in crossing tight lesions
Enhanced Trackability2
With an optimal tip design and improved balloon bonding, Ryurei provides enhanced trackability, even in tortuous anatomy and difficult to navigate vessels.
General specifications
​Shaft diameter ​1.9 Fr/0.64 mm Proximal • 2.5 Fr/0.84 mm Middle • 2.4 Fr/0.79 mm to 2.7 Fr/0.89 mm (tapered) Distal (1.00 to 1.50 mm) • 2.6 Fr/0.87 mm Distal (2.00 to 4.00 mm) ​Usable length ​145 cm ​Balloon markers # ​1(Ø1.0 to Ø 1.5 mm) • 2(Ø2.0 to Ø4.0 mm) ​Nominal pressure ​6 atm / 608 kPa ​Rated burst pressure Ø1.0 – 3.0 mm=14 atm(1419kPa) • Ø3.25 – 4.0 mm = 12 atm(1216 kPa) ​Guidewire compatibility ​Maximum diameter: 0.014″ / 0.36 mm ​Lesion entry profile ​0.41 mm (Ø1.00 to Ø1.50 mm) • 0.43 mm (Ø2.00 to Ø4.00 mm) ​Coating ​Hydrophilic Item specifications
Balloon length / Product code​​ ​ ​ ​ ​ ​
Balloon Diameter 5 mm 10 mm 15 mm 20 mm 30 mm 40 mm 1.00 mm DC-RR1005HH ​1.25 mm ​DC-RR1205HH ​​DC-RR1210HH ​​DC-RR1215HH ​​DC-RR1220HH ​ ​ 1.50 mm DC-RR1505HH DC-RR1510HH DC-RR1515HH DC-RR1520HH 2.00 mm DC-RR2010HHW DC-RR2015HHW DC-RR2020HHW DC-RR2030HHW DC-RR2040HHW 2.25 mm DC-RR2210HHW DC-RR2215HHW DC-RR2220HHW 2.50 mm DC-RR2510HHW DC-RR2515HHW DC-RR2520HHW DC-RR2530HHW DC-RR2540HHW 2.75 mm DCRR2710HHW DC-RR2715HHW DC-RR2720HHW 3.00 mm DC-RR3010HHW DC-RR3015HHW DC-RR3020HHW DC-RR3030HHW DC-RR3040HHW 3.25 mm DC-RR3210HHW DC-RR3215HHW DC-RR3220HHW 3.50 mm DC-RR3510HHW DC-RR3515HHW DC-RR3520HHW DC-RR3530HHW DC-RR3540HHW 3.75 mm DC-RR3710HHW DC-RR3715HHW DC-RR3720HHW 4.00 mm DC-RR4010HHW DC-RR4015HHW DC-RR4020HHW References
1 Ryurei φ1.00-5mm compared to Tazuna 1.25-10 mm- Data on file ISCD-416-31-4
* For Ryurei Ø 1.00 mm – Ø 1.50 mm.
** For Ryurei Ø 1.00mm – 5mm ​2 Compared to Tazuna PTCA dilatation catheter
-
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS









Reviews
There are no reviews yet.