PTCA BALLOON NC TREK
DES with most extensive clinical evidence with 50,000 patients enrolled worldwide. Facilitates early healing by abluminal gradient coating and reduced drug dose. Bifurcation Excellence. Flexible stent design. Advanced shaft technology. Reliable delivery in TRI.
The safety and effectiveness of this PTCA balloon catheter for the treatment of in-stent restenosis (ISR) has not been established. Potential Adverse Events.
The RX NC Takeru PTCA Balloon Dilatation Catheter is indicated for balloon dilatation of the stenotic portion in the coronary artery or bypass graft stenosis.
47732 – Basic Coronary Angioplasty Balloon Catheter … MINI TREK RX Coronary Dilatation Catheters. Catalog Numbers. Balloon Length. 6mm 8mm 12mm 15mm.
TECHNICAL INFORMATION
| NC TREK™ CORONARY DILATATION CATHETER | |
|---|---|
| NOMINAL PRESSURE (NP) | 12 atm |
| RATED BURST PRESSURE (RBP) | 18 atm |
| TIP ENTRY PROFILE | 0.020 in average (3.00 mm Ø) 0.022 in maximum (1.50 mm – 3.25 mm Ø) 0.024 in maximum (3.50 mm – 5.00 mm Ø) |
| CROSSING PROFILE | 0.027 in average (3.00 mm Ø) 0.032 in maximum (1.50 – 3.50 mm Ø) 0.037 in maximum (3.75 – 5.00 mm Ø) |
| RX NOTCH DIAMETER | 2.6 French average (3.00 mm Ø) 2.9 French maximum |
| TIP LENGTH | 3.5 +/- 0.5 mm (2.00 – 3.25 mm Ø) 4.5 +/- 0.5 mm (3.50 – 4.50 mm Ø) |
| BALLOON MATERIAL | Pebax‡, non-compliant |
| MARKER MATERIAL | Flexible Tungsten/Pebax‡ |
| SHAFT LENGTH | 143 cm |
| COATING | Hydrophilic |
| MAXIMUM GUIDE WIRE COMPATIBILITY | 0.014 in |
| LATEX FREE | Yes |

ORDERING INFORMATION
Broad Size Matrix with 59 Sizes Available
| BALLOON DIAMETER (MM) |
BALLOON LENGTH (MM) | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | ||
| NC TREK™ RX |
1.50 | 1012444-06 | 1012444-08 | 1012444-12 | 1012444-15 | 1012444-20 | – |
| 2.00 | 1012445-06 | 1012445-08 | 1012445-12 | 1012445-15 | 1012445-20 | – | |
| 2.25 | 1012446-06 | 1012446-08 | 1012446-12 | 1012446-15 | 1012446-20 | – | |
| 2.50 | 1012447-06 | 1012447-08 | 1012447-12 | 1012447-15 | 1012447-20 | 1012447-25 | |
| 2.75 | 1012448-06 | 1012448-08 | 1012448-12 | 1012448-15 | 1012448-20 | – | |
| 3.00 | 1012449-06 | 1012449-08 | 1012449-12 | 1012449-15 | 1012449-20 | 1012449-25 | |
| 3.25 | 1012450-06 | 1012450-08 | 1012450-12 | 1012450-15 | 1012450-20 | – | |
| 3.50 | 1012451-06 | 1012451-08 | 1012451-12 | 1012451-15 | 1012451-20 | 1012451-25 | |
| 3.75 | – | 1012452-08 | 1012452-12 | 1012452-15 | 1012452-20 | – | |
| 4.00 | – | 1012453-08 | 1012453-12 | 1012453-15 | 1012453-20 | – | |
| 4.50 | – | 1012454-08 | 1012454-12 | 1012454-15 | 1012454-20 | – | |
| 5.00 | – | 1012455-08 | 1012455-12 | 1012455-15 | 1012455-20 | – | |
COMPLIANCE CHART
| INFLATION PRESSURE (ATM) |
BALLOON DIAMETER (MM) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 | 2.00 | 2.25 | 2.50 | 2.75 | 3.00 | 3.25 | 3.50 | 3.75 | 4.00 | 4.50 | 5.00 | |
| 2 | 1.36 | 1.75 | 1.97 | 2.11 | 2.34 | 2.52 | 2.74 | 2.99 | 3.21 | 3.35 | 3.76 | 4.25 |
| 3 | 1.37 | 1.78 | 1.99 | 2.19 | 2.38 | 2.58 | 2.84 | 3.05 | 3.29 | 3.45 | 3.87 | 4.35 |
| 4 | 1.38 | 1.81 | 2.02 | 2.22 | 2.43 | 2.63 | 2.89 | 3.11 | 3.35 | 3.52 | 3.93 | 4.43 |
| 5 | 1.39 | 1.84 | 2.04 | 2.26 | 2.47 | 2.68 | 2.95 | 3.18 | 3.41 | 3.59 | 3.99 | 4.50 |
| 6 | 1.41 | 1.87 | 2.09 | 2.30 | 2.51 | 2.73 | 3.01 | 3.23 | 3.47 | 3.65 | 4.06 | 4.58 |
| 7 | 1.42 | 1.90 | 2.13 | 2.34 | 2.55 | 2.78 | 3.06 | 3.29 | 3.53 | 3.71 | 4.13 | 4.66 |
| 8 | 1.43 | 1.93 | 2.16 | 2.38 | 2.58 | 2.83 | 3.10 | 3.34 | 3.59 | 3.77 | 4.20 | 4.73 |
| 9 | 1.45 | 1.95 | 2.19 | 2.42 | 2.63 | 2.87 | 3.15 | 3.37 | 3.63 | 3.83 | 4.26 | 4.80 |
| 10 | 1.46 | 1.98 | 2.22 | 2.45 | 2.66 | 2.91 | 3.16 | 3.42 | 3.67 | 3.87 | 4.32 | 4.86 |
| 11 | 1.47 | 2.00 | 2.24 | 2.48 | 2.69 | 2.94 | 3.23 | 3.46 | 3.71 | 3.91 | 4.37 | 4.91 |
| 12 NP | 1.49 | 2.01 | 2.26 | 2.50 | 2.71 | 2.97 | 3.26 | 3.49 | 3.74 | 3.95 | 4.41 | 4.96 |
| 13 | 1.50 | 2.03 | 2.28 | 2.53 | 2.73 | 3.00 | 3.28 | 3.51 | 3.77 | 3.98 | 4.45 | 5.00 |
| 14 | 1.51 | 2.04 | 2.30 | 2.55 | 2.76 | 3.02 | 3.31 | 3.54 | 3.80 | 4.01 | 4.49 | 5.04 |
| 15 | 1.52 | 2.06 | 2.32 | 2.57 | 2.78 | 3.04 | 3.34 | 3.57 | 3.82 | 4.04 | 4.53 | 5.08 |
| 16 | 1.53 | 2.07 | 2.33 | 2.59 | 2.79 | 3.07 | 3.36 | 3.60 | 3.85 | 4.07 | 4.57 | 5.12 |
| 17 | 1.53 | 2.09 | 2.35 | 2.62 | 2.82 | 3.09 | 3.39 | 3.62 | 3.88 | 4.10 | 4.60 | 5.16 |
| 18 RBP | 1.54 | 2.10 | 2.37 | 2.64 | 2.84 | 3.11 | 3.41 | 3.65 | 3.91 | 4.13 | 4.64 | 5.20 |
| 19 | 1.55 | 2.12 | 2.39 | 2.67 | 2.86 | 3.14 | 3.44 | 3.68 | 3.93 | 4.16 | 4.68 | 5.24 |
| 20 | 1.56 | 2.13 | 2.41 | 2.69 | 2.88 | 3.16 | 3.47 | 3.71 | 3.96 | 4.19 | 4.72 | 5.28 |
| 21 | 1.57 | 2.15 | 2.42 | 2.72 | 2.90 | 3.18 | 3.50 | 3.75 | – | 4.22 | 4.76 | 5.33 |
| 22 | 1.58 | 2.17 | 2.45 | 2.75 | 2.93 | 3.21 | – | 3.78 | – | 4.25 | – | 5.37 |
Related products
-
Glide sheath
Product overview
Expanding trans-radial access to include more patients
- Glide sheath Slender is designed with a proprietary thin-wall technology where the outside diameter is reduced by one French size while the inner-diameter equivalent is maintained.
- Glide sheath Slender is coated with Terumo’s proprietary hydrophilic coating, allowing for smooth insertion and removal.
Features and Benefits

The proprietary thin-wall technology and Terumo M Coat hydrophilic coating
- Per the American Heart Association, dedicated radial sheaths with hydrophilic coating combined with smaller diameter sheaths and a tapered tip design may reduce risk of arterial spasm and radial occlusion1
- Featuring Terumo’s proprietary hydrophilic coating, the Glide sheath Slender Sheath is the only thin-wall radial sheath on the market to demonstrate superior and consistent performance in lubricity and durability over time
The Glide sheath Slender Sheath is the only thin-wall sheath that demonstrated best in class performance in all of the American Heart Association’s identified critical features that lead to reduced spasm.
THE POWER OF TERUMO GLIDE TECHNOLOGY™: LUBRICITY OVER TIMES
Hydrophilic coating is critical to procedural success, Physicians need to trust that their sheath will be just as lubricous at the end of case as it is at the beginning.
The graph below demonstrates the results of recent benchtop testing. The lower the value, the more lubricious the coating. The straighter the line, the more consistent, and reliable, the performance.
Glide sheath Slender Sheath outperformed the other competitive sheaths in both key features: lubricity and lubricity over time.

Unmatched Clinical Evidence
- A meta-analysis of 10 clinical papers, involving 3,821 patients, demonstrated that use of Glide sheath Slender Sheath is associated with high rates of procedural success and low rates in performance related issues.
- In studies measuring patient comfort, patients who underwent percutaneous trans-radial procedures with the Glide sheath Slender Sheath reported none to low amounts of pain.
-
SPRINTER LEGEND PTCA BALLOON
SPRINTER LEGEND 1.25 BALLOON CATHETER
Super Crosser Semi compliant Balloon Dilatation Catheter (RX/OTW)
Sprinter™ Legend™ 1.25 SuperCrosser semicompliant balloon dilatation catheter delivers exceptional crossability to treat today’s challenging lesions.
With innovative crossing technologies and 57 sizes, the Sprinter™ Legend™ RX semicompliant balloon dilatation catheter provides you with the power to cross.
OVERVIEW
During difficult cases, reach for a slim Sprinter™ Legend™ 1.25 mm Super Crosser semi compliant coronary balloon catheter featuring:
- Award-winning* Zerofold technology — no wrapped material and no balloon shoulders
- Low 0.5 mm (0.020 in) crossing profile
- OTW and RX platforms
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
1.25 SPL12506WL SPL12510WL SPL12515WL SPL12520WL Sprinter Legend RX Semi compliant
Balloon Dilatation Catheter
OVERVIEW
Performance You Can Trust
Sprinter™ Legend™ semicompliant balloons help you cross, open, and treat lesions during challenging percutaneous coronary interventions (PCIs), and feature:
- Some of the industry’s lowest crossing profiles1
- Innovative crossing technology
- A broad range of sizes
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
Balloon Diameter (mm)
1.25 SPL12506X SPL12510X SPL12512X SPL12515X 1.50 SPL15006X SPL15010X SPL15012X SPL15015X 2.00 SPL20006X SPL20010X SPL20012X SPL20015X 2.25 SPL22506X SPL22510X SPL22512X SPL22515X 2.50 SPL25006X SPL25010X SPL25012X SPL25015X 2.75 SPL27506X — SPL27512X SPL27515X 3.00 SPL30006X SPL30010X SPL30012X SPL30015X 3.25 — — SPL32512X SPL32515X 3.50 SPL35006X SPL35010X SPL35012X SPL35015X 3.75 — — SPL37512X SPL37515X 4.00 SPL40006X SPL40010X SPL40012X SPL40015X BALLOON LENGTHS 20, 25, AND 30 MM
Balloon Diameter (mm)
1.25 SPL12520X — — 1.50 SPL15020X — — 2.00 SPL20020X SPL20025X SPL20030X 2.25 SPL22520X SPL22525X — 2.50 SPL25020X SPL25025X SPL25030X 2.75 SPL27520X SPL27525X — 3.00 SPL30020X SPL30025X SPL30030X 3.25 SPL32520X — — 3.50 SPL35020X SPL35025X SPL35030X 3.75 SPL37520X — — 4.00 SPL40020X SPL40025X SPL40030X -
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILS†
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.†
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.†
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - ™Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Export™ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Export™ AP aspiration catheter without stylet.
-
RADIFOCUS INTRODUCER SHEATH
Radifocus™ Introducer II Standard Kit A
Introducer Sheath (FEMORAL)
Kit of vascular introducer with hemostatic valve with excellent blood tightness,
easy and non traumatic vessel insertion, patented valve design for a unique
features package.- Total Integrated Fit (TIF) tip tapering: tapering design at the tip of the sheath and dilator to facilitate smooth penetration
- Cross-cut hemostasis valve to avoid blood reflux and air aspiration
- Thin radiopaque sheath with anti-kinking sleeve for easy catheter handling
- Snap-on/click-off dilator lock prevents dilator back-out during insertion and allows one-hand unlocking
- Wide variety of kit variations providing all elements for quick vessel access: 4-11 Fr sheaths, 5-16 cm lengths, Surf lash needle
General specifications
Sheath length 10 cm Mini guidewire Plastic Straight and Angled
0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type; 0.035″ (0.89 mm) for all others
45 cmEntry needle Plastic IV Catheter – 18G x 2 ½” (1.2 x 64 mm),
except for 4 Fr with 45 cm straight mini guidewire: 20G x 2″ (0.9 x 51 mm)
2.5 ml syringe is includedGuidewire compatibility 0.025″ (0.64 mm) for 4 Fr, straight mini guidewire type
0.035″ (0.89 mm) for all othersPackaging Tray A Kit content Sheath, dilator, plastic mini guidewire and plastic IV catheter (entry needle) Item specifications
Inner diameter Mini guidewire type 45 cm angled 45 cm straight 4 Fr RS+A40K10AQ RS+A40G10SQ 4 Fr RS*A40G10SQ RS*A40G05SQ 4 Fr RS*A40K10SQ RS*A40G07SQ 5 Fr RS*A50K10AQ RS*A50G07SQ 5 Fr RS+A50K10AQ RS+A50K10SQ 6 Fr RS+A60K10AQ RS+A60K10SQ 6 Fr RS*A60K10AQ RS*A60G07SQ 6 Fr — RS*A60G16SQZ 6 Fr — RS*A60K10SQ 6 Fr — RS+A50K10SQ 7 Fr — RS+A70K10SQ 7 Fr — RS*A70G07SQ 7 Fr — RS*A70K10SQ 8 Fr — RS+A80K10SQ 8 Fr — RS*A80K10SQ 9 Fr — RS*A90K10SQ 10 Fr — RS*A10K10SQ 11 Fr — RS*A11K10SQ A Kit includes: introducer sheath, dilator, mini Guide wire, entry venous catheter, 2.5 cc syringe
B Kit includes: introducer sheath, dilator, mini Guide wire
C Kit includes: introducer sheath, dilator
R Kit includes: introducer sheath, dilator, mini Guide wire, 18 G x 2 3/4” / 1.2 x 70 mm entry metallic needle
Other code numbers are available on special demand. For any further information, please contact your Terumo local representative
Units per box: 5 for kits in tray and 10 for kits in pouch.