PTCA BALLOON NC TREK
DES with most extensive clinical evidence with 50,000 patients enrolled worldwide. Facilitates early healing by abluminal gradient coating and reduced drug dose. Bifurcation Excellence. Flexible stent design. Advanced shaft technology. Reliable delivery in TRI.
The safety and effectiveness of this PTCA balloon catheter for the treatment of in-stent restenosis (ISR) has not been established. Potential Adverse Events.
The RX NC Takeru PTCA Balloon Dilatation Catheter is indicated for balloon dilatation of the stenotic portion in the coronary artery or bypass graft stenosis.
47732 – Basic Coronary Angioplasty Balloon Catheter … MINI TREK RX Coronary Dilatation Catheters. Catalog Numbers. Balloon Length. 6mm 8mm 12mm 15mm.
TECHNICAL INFORMATION
| NC TREKâ„¢ CORONARY DILATATION CATHETER | |
|---|---|
| NOMINAL PRESSURE (NP) | 12 atm |
| RATED BURST PRESSURE (RBP) | 18 atm |
| TIP ENTRY PROFILE | 0.020 in average (3.00 mm Ø) 0.022 in maximum (1.50 mm – 3.25 mm Ø) 0.024 in maximum (3.50 mm – 5.00 mm Ø) |
| CROSSING PROFILE | 0.027 in average (3.00 mm Ø) 0.032 in maximum (1.50 – 3.50 mm Ø) 0.037 in maximum (3.75 – 5.00 mm Ø) |
| RX NOTCH DIAMETER | 2.6 French average (3.00 mm Ø) 2.9 French maximum |
| TIP LENGTH | 3.5 +/- 0.5 mm (2.00 – 3.25 mm Ø) 4.5 +/- 0.5 mm (3.50 – 4.50 mm Ø) |
| BALLOON MATERIAL | Pebax‡, non-compliant |
| MARKER MATERIAL | Flexible Tungsten/Pebax‡ |
| SHAFT LENGTH | 143 cm |
| COATING | Hydrophilic |
| MAXIMUM GUIDE WIRE COMPATIBILITY | 0.014 in |
| LATEX FREE | Yes |

ORDERING INFORMATION
Broad Size Matrix with 59 Sizes Available
| BALLOON DIAMETER (MM) |
BALLOON LENGTH (MM) | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | ||
| NC TREKâ„¢ RX |
1.50 | 1012444-06 | 1012444-08 | 1012444-12 | 1012444-15 | 1012444-20 | – |
| 2.00 | 1012445-06 | 1012445-08 | 1012445-12 | 1012445-15 | 1012445-20 | – | |
| 2.25 | 1012446-06 | 1012446-08 | 1012446-12 | 1012446-15 | 1012446-20 | – | |
| 2.50 | 1012447-06 | 1012447-08 | 1012447-12 | 1012447-15 | 1012447-20 | 1012447-25 | |
| 2.75 | 1012448-06 | 1012448-08 | 1012448-12 | 1012448-15 | 1012448-20 | – | |
| 3.00 | 1012449-06 | 1012449-08 | 1012449-12 | 1012449-15 | 1012449-20 | 1012449-25 | |
| 3.25 | 1012450-06 | 1012450-08 | 1012450-12 | 1012450-15 | 1012450-20 | – | |
| 3.50 | 1012451-06 | 1012451-08 | 1012451-12 | 1012451-15 | 1012451-20 | 1012451-25 | |
| 3.75 | – | 1012452-08 | 1012452-12 | 1012452-15 | 1012452-20 | – | |
| 4.00 | – | 1012453-08 | 1012453-12 | 1012453-15 | 1012453-20 | – | |
| 4.50 | – | 1012454-08 | 1012454-12 | 1012454-15 | 1012454-20 | – | |
| 5.00 | – | 1012455-08 | 1012455-12 | 1012455-15 | 1012455-20 | – | |
COMPLIANCE CHART
| INFLATION PRESSURE (ATM) |
BALLOON DIAMETER (MM) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.50 | 2.00 | 2.25 | 2.50 | 2.75 | 3.00 | 3.25 | 3.50 | 3.75 | 4.00 | 4.50 | 5.00 | |
| 2 | 1.36 | 1.75 | 1.97 | 2.11 | 2.34 | 2.52 | 2.74 | 2.99 | 3.21 | 3.35 | 3.76 | 4.25 |
| 3 | 1.37 | 1.78 | 1.99 | 2.19 | 2.38 | 2.58 | 2.84 | 3.05 | 3.29 | 3.45 | 3.87 | 4.35 |
| 4 | 1.38 | 1.81 | 2.02 | 2.22 | 2.43 | 2.63 | 2.89 | 3.11 | 3.35 | 3.52 | 3.93 | 4.43 |
| 5 | 1.39 | 1.84 | 2.04 | 2.26 | 2.47 | 2.68 | 2.95 | 3.18 | 3.41 | 3.59 | 3.99 | 4.50 |
| 6 | 1.41 | 1.87 | 2.09 | 2.30 | 2.51 | 2.73 | 3.01 | 3.23 | 3.47 | 3.65 | 4.06 | 4.58 |
| 7 | 1.42 | 1.90 | 2.13 | 2.34 | 2.55 | 2.78 | 3.06 | 3.29 | 3.53 | 3.71 | 4.13 | 4.66 |
| 8 | 1.43 | 1.93 | 2.16 | 2.38 | 2.58 | 2.83 | 3.10 | 3.34 | 3.59 | 3.77 | 4.20 | 4.73 |
| 9 | 1.45 | 1.95 | 2.19 | 2.42 | 2.63 | 2.87 | 3.15 | 3.37 | 3.63 | 3.83 | 4.26 | 4.80 |
| 10 | 1.46 | 1.98 | 2.22 | 2.45 | 2.66 | 2.91 | 3.16 | 3.42 | 3.67 | 3.87 | 4.32 | 4.86 |
| 11 | 1.47 | 2.00 | 2.24 | 2.48 | 2.69 | 2.94 | 3.23 | 3.46 | 3.71 | 3.91 | 4.37 | 4.91 |
| 12 NP | 1.49 | 2.01 | 2.26 | 2.50 | 2.71 | 2.97 | 3.26 | 3.49 | 3.74 | 3.95 | 4.41 | 4.96 |
| 13 | 1.50 | 2.03 | 2.28 | 2.53 | 2.73 | 3.00 | 3.28 | 3.51 | 3.77 | 3.98 | 4.45 | 5.00 |
| 14 | 1.51 | 2.04 | 2.30 | 2.55 | 2.76 | 3.02 | 3.31 | 3.54 | 3.80 | 4.01 | 4.49 | 5.04 |
| 15 | 1.52 | 2.06 | 2.32 | 2.57 | 2.78 | 3.04 | 3.34 | 3.57 | 3.82 | 4.04 | 4.53 | 5.08 |
| 16 | 1.53 | 2.07 | 2.33 | 2.59 | 2.79 | 3.07 | 3.36 | 3.60 | 3.85 | 4.07 | 4.57 | 5.12 |
| 17 | 1.53 | 2.09 | 2.35 | 2.62 | 2.82 | 3.09 | 3.39 | 3.62 | 3.88 | 4.10 | 4.60 | 5.16 |
| 18 RBP | 1.54 | 2.10 | 2.37 | 2.64 | 2.84 | 3.11 | 3.41 | 3.65 | 3.91 | 4.13 | 4.64 | 5.20 |
| 19 | 1.55 | 2.12 | 2.39 | 2.67 | 2.86 | 3.14 | 3.44 | 3.68 | 3.93 | 4.16 | 4.68 | 5.24 |
| 20 | 1.56 | 2.13 | 2.41 | 2.69 | 2.88 | 3.16 | 3.47 | 3.71 | 3.96 | 4.19 | 4.72 | 5.28 |
| 21 | 1.57 | 2.15 | 2.42 | 2.72 | 2.90 | 3.18 | 3.50 | 3.75 | – | 4.22 | 4.76 | 5.33 |
| 22 | 1.58 | 2.17 | 2.45 | 2.75 | 2.93 | 3.21 | – | 3.78 | – | 4.25 | – | 5.37 |
Related products
-
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT)Â *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.
-
EXPORT ADVANCE ASPIRATION CATHETER
EXPORT ADVANCE ASPIRATION CATHETER
Export Advance
Aspiration Catheter
ADVANCING PERFORMANCE
The Export Advance™ aspiration catheter delivers consistent, high-performing aspiration power when it matters most — restoring flow and protecting patients.
PRODUCT DETAILSâ€
Superior Deliverability1
Full-Wall Technology provides variable levels of stiffness without joints, for optimal kink resistance and catheter performance.
Dependable Delivery to the Target Site:
- Preloaded stylet enhances shaft stiffness during catheter delivery, boosting kink resistance, trackability, and pushability2
- Buddy wire compatibility allows for extra support, when needed.â€
High-performing Aspiration Power:
- Large extraction lumen (0.044″ proximal; 0.043″ distal) increases aspiration power.‡
- Optimised hub geometry improves flow.‡
- Soft, short, forward-facing tip design permits excellent particle capture.â€
ORDERING INFORMATION
ADVANCE 6 F min. guide I.D. 0.070″ 0.014 140 - â„¢Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
- Based on bench test data, 2013. Bench test data may not be indicative of clinical performance.
- Based on bench test data vs. Exportâ„¢ AP catheter.
- Bench testing vs. Terumo Eliminate™* and Eliminate™* 3 aspiration catheters, Vascular Solutions Pronto®* LP, Pronto®* V3 and Pronto®* V4 aspiration catheters, Merit®* ASAP aspiration catheter, Kaneka Thrombuster III GR* aspiration catheter, Spectranetics QuickCat™* aspiration catheter, IHT Polska Hunter®* aspiration catheter, Medrad Possis™* Fetch™* 2 aspiration catheter, and Hexacath Recover* aspiration catheter. 10093906DOC, 2013. Bench test data may not be indicative of clinical performance.
- Based on animal studies compared with Exportâ„¢ AP aspiration catheter without stylet.
-
Launcher- 8f Guiding Catheter’s
EBU@ (Extra Backup)
LA8EBU30 (EBU 3.0)
LA8EBU35 (EBU 3.5)
LA8EBU375 (EBU 3.75)
LA8EBU40 (EBU 4.0)
LA8EBU45 (EBU 4.5)
LA8EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA8JL30 (JL 3.0)
LA8JL35 (JL 3.5)
LA8JL40 (JL 4.0)
LA8JL45 (JL 4.5)
LA8JL50 (JL 5.0)
LA8JL60 (JL 6.0)
JR@ (Judkin Right )
LA8JR30 (JR 3.0)
LA8JR35 (JR 3.5)
LA8JR40 (JR 4.0)
LA8JR45 (JR 4.5)
LA8JR50 (JR 5.0)
LA8JR60 (JR 6.0)
AL@ (Amplatz Left )
LA8AL75 (AL .75)
LA8AL10 (AL 1.0)
LA8AL15 (AL 1.5)
LA8AL20 (AL 2.0)
LA8AL25 (AL 2.5)
LA8AL30 (AL 3.0)
LA8AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA8SAL75 (SAL . 75)
LA8SAL10 (SAL 1.0)
LA8SAL15 (SAL 1.5)
LA8SAL20 (SAL 2.0)
LA8SAL25 (SAL 2.5)
LA8SAL30 (SAL 3.0)
LA8SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA8AR10 (AR 1.0)
LA8AR20 (AR 2.0)
LA8ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA8ECR35 (ECR 3.5)
LA8ECR40 (ECR 4.0)
LA8ECR45 (ECR 4.5)
LA8RBU35 (RBU 3.5)
LA8RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA8SCR35 (SCR 3.5)
LA8SCR40 (SCR 4.0)
LA8SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA8SAR10 (SAR 1.0)
LA8SAR20 (SAR 2.0)
Multipurpose@
LA8MB1 (MB 1)
LA8MB2 (MB 2)
LA8HSREL (Hockey Stick)
LA8HSI (Hockey I)
LA8HSII (Hockey II)
LA8HSIII (Hockey III)
Bypass Crafts@
LA8LCB (LCB)
LA8RCB (RCB)
LA8RCB (RCB III)
LA8RCB (RCBÂ 90cm)
LA8IMA (IMA)
LA8IMA (IMAÂ 90cm)
-
RADIFOCUS REDIAL SHEATH
Providing you the best range of Terumo Radifocus Radial Introducer Sheath and Cordis Femoral Introducer Sheath with effective & timely delivery.
The radial artery access sheath is used to gain arterial access and facilitate the insertion of catheters or other equipment for diagnostic and vascular interventions.
- The Cordis AVANTI®+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a patented SLIX Valve, the AVANTI®+ introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates procedural flexibility. It stays in place and allows patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and helps to minimize damage upon entry.
As part of the circulatory system, the radial artery supplies blood from the heart to the forearm.
Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.









Reviews
There are no reviews yet.