CALL : 8447755671 , 77019 18238

Cart

Your Cart is Empty

Back To Shop

ACT MACHINE

(3 customer reviews)

ACT PLUS AUTOMATED COAGULATION TIMER

SYSTEM

Precise, Reliable – The Trusted Standard

BLOOD DIAGNOSTICS AND CLOT DETECTION
In addition to running cardiopulmonary bypass, we know that you rely on accurate blood diagnostic results.

The ACT Plus® System combines a trusted standard in precise clot detection technology with state-of-the-art user features including data management and connectivity-ready capabilities. It is a microprocessor-controlled electromechanical coagulation instrument designed to determine coagulation endpoints in fresh and citrated whole blood samples. Clotting-time results are presented on the instrument’s Clot Time Display (CTD) and Liquid Crystal Display (LCD) screens.

The ACT Plus System provides long-term data storage and retrieval, with access to previous patient and quality control test data. Test results are stored in the order in which they are performed. The ability to externally transfer or save data enhances the system’s versatility.

The ACT Plus System is portable and well suited for all point-of-care testing situations. It offers the reliability required in:

Cardiovascular and vascular surgery
ECMO
Cardiac catheterization laboratories
Critical care units
Hemodialysis units
MANAGE YOUR ACT PLUS SYSTEM DATA EFFICIENTLY AND EFFECTIVELY
As part of our ongoing commitment to helping you manage your work efficiently and effectively, we offer the ACT Plus EDM external data manager to accompany the ACT Plus Automated Coagulation Timer System.

By combining this powerful software with the ACT Plus System, you will have access to the reports you’ll need to analyze test results and make informed decisions. This timesaving data management solution offers added convenience, reassurance and confidence—allowing you to stay focused on improving patient outcomes.

The ACT Plus EDM is a versatile Microsoft Access-based data management software application that runs on a PC and is designed to help you manage your patient, QC, instrument and user ID data. All aspects of Microsoft Access software required to run the application are included with the ACT Plus EDM.

 

ACT Plus Instrument
Order Number Description # of Units
ACT100 ACT Plus System is a microprocessor-controlled electromechanical coagulation instrument for determination of activated coagulation times 1 per box
ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box
402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box
402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box
402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box

 

ACT® CLOTtrac® Coagulation Controls
550-01 CLOTtrac CWB Coagulation Control – Verify performance of 402-01 and 402-02 cartridges, and the ACT Plus Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac CWB coagulation control) 15 per box
550-07 CLOTtrac HR Coagulation Control – Verify performance of 402-03, and 402-07 cartridges and the ACT Plus Instrument 15 per box
550-08 CLOTtrac HR Abnormal Coagulation Control – Verify performance of 402-03 cartridges and the ACT Plus Instrument 15 per box
550-09 CLOTtrac LR Abnormal Coagulation Control – Verify performance of 402-01 cartridges and the ACT Plus® Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac LR abnormal coagulation control) 15 per box
550-10 CLOTtrac RACT Abnormal Coagulation Control – Verify performance of 402-02 cartridges and the ACT Plus® Instrument 15 per box
550-12 CLOTtrac HTC Coagulation Control – Verify performance of 402-07 cartridges and the ACT Plus® Instrument 15 per box
550-13 CLOTtrac HR Control Pack – Verify performance of 402-03 cartridges and the ACT Plus Instrument (contains 15 HR Normal and 15 HR Abnormal) 15 per box
550-11 Calcium Chloride 5 ml vial – Use with control nos. 550-01, 550-09 in cartridge 402-01 15 per box

3 reviews for ACT MACHINE

  1. https://bandur-art.blogspot.com/2024/08/the-ultimate-guide-to-no-mans-sky-mods.html

    We’re a group of volunteers and starting a new scheme in our community.
    Your site provided us with valuable information too work
    on. You’ve done an impressive jjob and our entire community will be grateful to you. https://bandur-art.blogspot.com/2024/08/the-ultimate-guide-to-no-mans-sky-mods.html

  2. Quiernera

    The amplitude and latency of these ERP polarity peaks are thought to reflect the strength and timing of cognitive processes, suggesting that adult loss of CDKL5 also impairs sensory information processing in conjunction with compromised behavioral functions buy priligy online

  3. Dichaelsok

    Hey! Do you know if they make any plugins to assist with SEO? I’m trying to get my blog to rank for some targeted keywords but I’m not seeing very good success. If you know of any please share. Thanks!
    https://rainbetaustralia.com/

Add a review

Your email address will not be published. Required fields are marked *

Category:

Cart

Your Cart is Empty

Back To Shop