AVANTI®+ INTRODUCER SHEATH
Product Description
Sheath introducers (Cordis) central lines are large-bore catheters (6-8.5 Fr) commonly placed in the ED for rapid infusion of large volumes of crystalloid or colloid, insertion of transvenous pacemakers, and administration of medications that needing reliable central access.
For use in arterial and venous procedures requiring percutaneous introduction of Intravascular devices.
The Cordis AVANTI+ Introducer is the pioneer of catheter sheath introducer technology. Featuring a SLIX Valve, the AVANTI+ Introducer provides smooth transitions, monitoring capabilities and exceptional performance for your procedural success, as well as:
- A hexacuspid design that provides a balance between catheter maneuverability and hemostasis.
- A rotating suture collar that facilitates greater procedural flexibility. It stays in place better and allows more patient movement.
- A kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer for improved bendability and support. It is also less prone to kinking, cost-effective and reliable.
- Atraumatic tip transitions for both the sheath and the vessel dilator are uniquely tapered and manicured. This results in smooth insertions and may help lessen damage upon entry.
What size is a Cordis? A Cordis/AVANTI comes in many sizes. For the sake of rapid infusion, the sizes go from 8-11 french. There are two lengths of the large-bore cannula: 11cm and 23cm.
Introducer sheaths are used when there is the need for a larger catheter, such as for rapid volume administration or for the insertion of a pulmonary artery catheter.
The Correct Way to Pull a Sheath
- Take your index, middle and sometimes your ring finger, and place them slightly above the sheath to feel the patient’s pulse.
- Slowly remove the sheath in a sterile manner, holding occlusive pressure to avoid bleeding.
Our product range includes a wide range of Avanti transradial kit, cordis vista brite tip guiding catheters, emerald guidewire 150cm, guiding catheter 5f xb 3.5lbt, femoral sheath and empira ptca balloons cordis.
We are one of the leading Trader, Importer and Exporter of this highly commendable and diverse range of Aspiration Catheter, Transseptal Needle, Control Coronary Syringes, Introducer Sets etc.
AVANTI®+ INTRODUCER SHEATH
Related products
-
INFINITI DAIGNOSTIC CATHETER
The Cordis INFINITI 4F, 5F and 6F line of diagnostic catheters is ideal for coronary angioplasty. These catheters incorporate proprietary Vestan Nylon to deliver exceptional responsiveness and flow rates, optimal torque, and shape retention.
Product Description
The INFINITI 4F, 5F and 6F Diagnostic Catheters are ideal for coronary angioplasty. These catheters incorporate proprietary VESTAN Nylon to deliver exceptional responsiveness and flow rates, optimal torque, and shape retention.
- The THRULUMEN™ Design: provides the same inner lumen diameter from hub to tip, which eliminates contrast jetting and allows for smoother flow and improved catheter stability.
- Large inner lumen: thin-wall technology allows for larger inner lumen diameter, thus facilitating easy injections and higher flow rates.
- Radiopaque tip: helps reduce the risk of vascular damage upon entering tortuous or fragile vessels.
1、Soft tip reduces potential for vessel trauma
2、Double braided stainless steel for 1:1 torque control
3、Maximum pressure:1200psi/ 84 bar
4、Maximum Guide wire:0.038″/ 0.97mmshape
Shape Name
Fr Size
Ref. NO.
Length
(cm)Side Hole
Shape Illustration
TIG
Radial TIG
4F
ACTIG14F1100
100
1
Radial TIG
5F
ACTIG15F1100
100
1
Radial TIG
6F
ACTIG16F1100
100
1
Radial TIG
7F
ACTIG17F1100
100
1
Pigtail
Straight Pigtail
5F
ACPIGS5F1110
110
6
Straight Pigtail
6F
ACPIGS6F1110
110
5
Straight Pigtail with 20 marked band
5F
ACPIGS5F20M10H1100
100
10
145° Angled Pigtail
5F
ACPIGA5F1110
110
6
145° Angled Pigtail
6F
ACPIGA6F1110
110
6
Judkins Left
JL3.5
5F
ACJL355F1100
100
/
JL3.5
6F
ACJL356F1100
100
/
JL4.0
5F
ACJL405F1100
100
/
JL4.0
6F
ACJL406F1100
100
/
JL4.5
5F
ACJL455F1100
100
/
JL4.5
6F
ACJL456F1100
100
/
JL5.0
5F
ACJL505F1100
100
/
JL5.0
6F
ACJL506F1100
100
/
Judkins Right
JR3.5
5F
ACJR355F1100
100
/
JR3.5
6F
ACJR356F1100
100
/
JR4.0
5F
ACJR405F1100
100
/
JR4.0
6F
ACJR406F1100
100
/
JR5.0
5F
ACJR505F1100
100
/
JR5.0
6F
ACJR506F1100
100
/
JR6.0
5F
ACJR605F1100
100
/
JR6.0
6F
ACJR606F1100
100
/
Amplatz Left
AL 1
5F
ACAL15F1100
100
/
AL 1
6F
ACAL16F1100
100
/
AL 2
5F
ACAL25F1100
100
/
AL 2
6F
ACAL26F1100
100
/
AL 3
5F
ACAL35F1100
100
/
AL 3
6F
ACAL36F1100
100
/
Amplatz Right
AR 1
5F
ACAR15F1100
100
/
AR 1
6F
ACAR16F1100
100
/
AR 2
5F
ACAR25F1100
100
/
AR 2
6F
ACAR26F1100
100
/
AR 3
5F
ACAR35F1100
100
/
AR 3
6F
ACAR36F1100
100
/
COBRA
COBRA
5F
ACCOBRA15F0065
65
/
COBRA
6F
ACCOBRA16F0065
65
/
-
(OPTEASE/TRABEASE) IVC FILTER
OPTEASE Retrievable Vena Cava Filters are an innovative option for prevention of recurrent pulmonary embolism.
Product Description
OPTEASE Retrievable Vena Cava Filters are an option for prevention of pulmonary embolism.
- Dual-layer filtration for easier clot capture and prevention of pulmonary embolism
- Fixation barb minimizes migration to maintain clot capture efficiency
- Caudal filter retrieval hook for easy retrieval with any appropriate endovascular snare
- Caval coverage up to 30 mm
- Nitinol technology No waiting period is required between filter placement and having an MRI
One OPTEASE Retrievable Vena Cava Filter kit provides more options:
- 90cm kit allows filter delivery through six entry sites (right and left femoral, jugular, and antecubital veins)
- 55cm kit allows filter delivery through four entry sites (right and left femoral and jugular veins)
- No need to change systems when changing access sites.
Cordis Optease & trabease IVC Filter Injuries Cordis Corporation makes the Optepse and Trapease IVC filters, which are designed to prevent pulmonary embolisms Unfortunately, recent studies have found alarming rates of filter fracture, perforation, migration, and tilting when the filters are not removed after a few months.
Cordis Corporation makes two IVC filters, the OptEase and TrapEase. These devices are implanted in the inferior vena cava (IVC) to block blood clots from the leg before they cause pulmonary embolism.
The Cordis Trabease is a permanent vena cava filter, which was approved by the FDA in 2001.
-
TRANSREDIAL SHEATH
Elastomeric properties allow RAIN Sheath Introducer to flex and bend in the radial anatomy. RAIN Sheath Introducer’s polymeric material reduces the impact of kinking – avoiding the sharp edges that can injure the vessel wall and contribute to complications.
LOW
PROFILE DESIGN
Available in:
7F in 6, 6F in 5, 5F in 4, 4F
in 3
Enables maximum operating
space while minimizing
puncture sizePROPRIETARY
KINK RECOVERY
TECHNOLOGY™
Elastomeric properties
allow the RAIN Sheath™
Introducer to bend and flex
to maintain lumen integrity
LUBRICIOUS HYDROPHILICCOATING
Facilitates smoother, easier
insertion and removalHEXACUSPID
HEAMOSTASIS VALVE
Designed to preserve
hemostasis and reduce risk
of bleedbackLOW PROFILE WITH OPTIMAL GUIDE
CATHETER SUPPORT
Available in 4F, 5F, 6F, 7F and 10 cm and 16 cm lengths
• Provides structure and stability without adding thickness
• Optimizes operating space while minimizing the access size
• Minimizes radial puncture size, a key factor in reducing vessel spasm
and radial artery occlusion1.OPTIMISED TRANSITIONS
• Designed for atraumatic insertion
• Smooth transitions and tapered tip
to reduce insertion force.STAINLESS STEEL WIRE
• Flex Straight tip
• 0.021″ diameter x 45cm length
• For use with 21G metallic needlesNITINOL WIRE
• Floppy tip
• 0.021″ diameter x 45cm length
• Bare wire: For use with 21G metallic needles
• Hydrophilic wire: For use with 20G IV cathetersPOLYMER WIRE
• Short angle tip
• 0.021″ diameter x 45cm length
• For use with 20G and 22G IV Catheter needles -
ASAHI SION® blue
ASAHI SION® blue
Well Balanced Workhorse
Frontline guide wire with proprietary ACT ONE construction for greater tip flexibility, durability and torque response.
(Easily-discernible shaft color for differentiation from other ASAHI wires.)
TIP LOAD TIP RADIOPACITY 3 cm COATING HYBRID COATING: HYDROPHILIC* WITH HYDROPHOBIC TIP
Hydrophobic Coating: Tip to 1.5 cm
Hydrophilic Coating: 18.5 cmTIP SHAPE Resources
Guide wire differences between Torque and no Torque
Traversing a tortuous vessel, whether for Interventional Cardiology or Interventional Neurology can require a guide wire that is an extended version of the Interventional Cardiologist or Neurologist own finger. To achieve this, torque technology, like ASAHI’s own patented guide wires, is needed for accurate pushback and little to no whip. See a firsthand example of a guide wire with and without this torque ability.
Crossing the Y-Branch
A side branch occlusion? a tortuous vessel? Not a problem with the right ASAHI INTECC guide wire technology. See it for yourself!
Ordering Information
To order, please call us toll-free at 855-286-9473, or email us at customersupport@asahi-intecc.com. To see a complete listing of all available ASAHI products, go to our Full Product Listing page.
PRODUCT CATALOG NO. TIP SHAPE LENGTH (CM) DIAMETER (INCH(MM)) RADIOPAQUE SEGMENT (CM) SPRING COIL LENGTH (CM) COATING ASAHI SION blue PTCA GW 190 cm, Straight AHW14R104S Straight 190 0.014 (0.36) 3 20 Hybrid Coating: Hydrophilic* with Hydrophobic Tip ASAHI SION blue PTCA GW 190 cm, J Shape AHW14R104J J Shape 190 0.014 (0.36) 3 20 Hybrid Coating: Hydrophilic* with Hydrophobic Tip ASAHI SION blue PTCA GW 300 cm, Straight AHW14R304S Straight 300 0.014 (0.36) 3 20 Hybrid Coating: Hydrophilic* with Hydrophobic Tip ASAHI SION blue PTCA GW 300 cm, J Shape AHW14R304J J Shape 300 0.014 (0.36) 3 20 Hybrid Coating: Hydrophilic* with Hydrophobic Tip *Coated with SLIP-COAT® coating
Indications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
Reviews