FIELDERĀ® FC
FIELDERĀ® FC
Greater control in challenging tortuous vessels/highly stenosed lesions. Polymer jacket provides advanced lubricity for superior torque.

| TIP LOAD | |
| TIP RADIOPACITY | 3 cm |
| COATING | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
| TIP SHAPE | Ā ![]() |
Ordering Information
| PRODUCT | CATALOG NO. | TIP SHAPE | LENGTH (CM) | DIAMETER (INCH(MM)) | RADIOPAQUE SEGMENT (CM) | SPRING COIL LENGTH (CM) | COATING |
|---|---|---|---|---|---|---|---|
| FIELDER FC 180cm, Straight | AGP140001 | Straight | 180 | 0.014 (0.36) | 3 | 11 | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
| FIELDER FC 180cm, J Shape | AGP140001J | J Shape | 180 | 0.014 (0.36) | 3 | 11 | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
| FIELDER FC 300cm, Straight | AGP140301 | Straight | 300 | 0.014 (0.36) | 3 | 11 | POLYMER JACKET & HYDROPHILIC* Hydrophilic coating over polymer jacket: 20cm |
Indications for Use
ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.
Related products
-
CLOSUREFAST
ClosureFastā¢Ā
procedureMinimally invasive thermal
treatment for vein disease
and varicose veins.
The ClosureFast procedure uses radiofrequency energy or heat to close the diseased vein, which redirects blood flow to healthyĀ veins, relieving symptoms.Before the procedure
You will have an ultrasound imaging exam of the leg beingĀ treated. This exam is important for assessing the diseasedĀ superficial vein and planning the procedure.
During the procedure
Your doctor will discuss the procedure with you. Here is a brief summary of what to expect:
- The ClosureFast procedure is performed on an outpatient basis. Your doctor will perform the ClosureFast procedure. Using anĀ ultrasound, your doctor will position a catheter in the diseased vein through a small opening in the skin.
- The small catheter delivers heat to the vein wall, causing it to shrink and seal the vein. Once the diseased vein is closed, blood will reroute itself to other healthy veins.
After the procedure
- You will be taken to the recovery area to rest.
- Following the procedure, your doctor will apply a simpleĀ bandage over the insertion site and will give you compressionĀ stockings to aid in the healing process. Your doctor may encourage you to walk and to refrain from extended standing and strenuous activities for a period of time. The average patient typically resumes normal activities within a few days.1,2
- Your doctor will recommend follow-up care as needed.
-
Benefits of the ClosureFast procedure
- Relief of symptoms after two days, with a noticeable improvement in one to two week
- Minimally invasive outpatient procedure
- Less pain and bruising than laser treatment
- Faster recovery than laser treatment
- Proven results with positive patient experience
Ā
- Rapid recovery ā on average, patients resume normal activities within a few days
- Lasting results ā the only radiofrequency energy procedure with published long-term clinical data demonstrating safety and efficacy, with a 91.9% closure rate at five years.4
Adverse events can include nerve injury, hematoma, phlebitis, thrombosis, and/or pulmonary embolism.
Type of therapy
Thermal shrinkage of the vein wall with radiofrequency energy or heatInpatient or outpatient procedure
Outpatient procedureOne- versus two-leg treatment
Typically, each leg will be treated in separate appointmentsNeedle sticks required
One needle stick for vein access.Ā Typically, 5 to 10 needle sticks for anesthesia.Ā
Typical post-treatment recovery
Healing of vein access site, anesthetic needleĀ stick sites, and alsoĀ healing ofĀ ablated vein sectionCompression hose
Required for approximately one weekProcedure success rate
91.9% after five years4
ClosureFast procedure FAQ
Is the ClosureFast procedure painful?
Most patients report feeling little, if any, pain during the ClosureFast procedure.3Ā Your doctor will give you a local or regionalĀ anesthetic to numb the treatment area.
When can I return to normal activity?
Patients treated with the ClosureFast procedure may resume normal activity more quickly than patients who undergo surgical veinĀ stripping or laser ablation. With the ClosureFast procedure, the average patient typically resumes normal activity within a few days.2Ā For a few weeks following the treatment, your vein specialist may recommend a regular walking regimen and suggest you refrainĀ from strenuous activities (heavy lifting, for example) or prolonged periods of standing.
When will my symptoms improve?
Most patients report relief of symptoms after two days, with a noticeable improvement in one to two weeks.
Is there any scarring, bruising, or swelling after the procedure?
Most patients report limited to no scarring, bruising, or swelling following the ClosureFast procedure.3
How is the ClosureFast procedure different from endovenous lasers?
Both Closure Fast and lasers use thermal technology to deliver heat into the diseased vein, but they each use a different method of delivery. Despite their similarity in using heat, a 2009 study showed that the ClosureFast procedure is associated with lower rates of pain, bruising, and complications and a faster improvement in patientsā quality of life when compared to 980 nm laser ablation.4
How is the Closure FastĀ procedure different from vein stripping?
During vein stripping, incisions are made in the groin and calf, and a tool is threaded through the diseased vein to pull the vein outĀ of the leg. With the ClosureFast procedure, only one small incision is made at the insertion site and the vein is then treated and leftĀ in place. ClosureFast is a minimally invasive approach that reduces the likelihood of pain and bruising, associated with vein strippingĀ surgery.1
Is the ClosureFast procedure covered by insurance?
Many patients have access to the ClosureFast procedure through their insurance coverage plan. Insurance companies detail access to the ClosureFast procedure and other radiofrequency ablation procedures in coverage policies for varicose veins or chronic venous insufficiency. As with all healthcare procedures, you may also have some cost associated with receiving treatment, such as a copay or coinsurance. Please reach out to your insurance company to discuss your specific plan coverage and potential costs prior to seeking treatment
-
NC EUPHORA NONCOMPLIANT BALLOON CATHETER
NC Euphora⢠noncompliant balloon
NC Euphora⢠noncompliant balloon dilatation catheter combines Euphora technology with controlled, high-pressure performance.
Balloon Dilatation Catheter
OVERVIEW
From Collaboration to Innovation
When it comes to controlled, high-pressure performance, the NC Euphora⢠noncompliant balloon dilatation catheter has what youāre looking for:
- High RBP up to 20 atm
- Low-growth profile1
- Superior deliverability1
In fact, we worked with nearly 2,000 interventional cardiologists and cath lab professionals to develop it ā so you can choose it with confidence for your patients.
PRODUCT DETAILS
Looking for NC Euphora Noncompliant Performance?
ORDERING INFORMATION
BALLOON LENGTHS 6, 8, AND 12 MM
Balloon
Diameter
(mm)Balloon Length (mm) 6 8 12 2.00 NCEUP2006X NCEUP2008X NCEUP2012X 2.25 NCEUP22506X NCEUP22508X NCEUP22512X 2.50 NCEUP2506X NCEUP2508X NCEUP2512X 2.75 NCEUP27506X NCEUP27508X NCEUP27512X 3.00 NCEUP3006X NCEUP3008X NCEUP3012X 3.25 NCEUP32506X Ā NCEUP32508X Ā NCEUP32512X 3.50 NCEUP3506X Ā NCEUP3508X Ā NCEUP3512X 3.75 NCEUP37506X Ā NCEUP37508X Ā NCEUP37512X 4.00 NCEUP4006X Ā NCEUP4008X Ā NCEUP4012X 4.50 Ā ā Ā NCEUP4508X Ā NCEUP4512X 5.00 Ā ā Ā NCEUP5008X Ā NCEUP5012X BALLOON LENGTHS 15, 20, AND 27 MM
Balloon
Diameter
(mm)Balloon Length (mm) 15 20 27 2.00 NCEUP2015X NCEUP2020X ā 2.25 NCEUP22515X NCEUP22520X ā 2.50 NCEUP2515X NCEUP2520X NCEUP2527X 2.75 NCEUP27515X NCEUP27520X NCEUP27527X 3.00 NCEUP3015X NCEUP3020X NCEUP3027X 3.25 Ā NCEUP32515X Ā NCEUP32520X Ā NCEUP32527X 3.50 Ā NCEUP3515X Ā NCEUP3520X Ā NCEUP3527X 3.75 Ā NCEUP37515X Ā NCEUP37520X Ā NCEUP37527X 4.00 Ā NCEUP4015X Ā NCEUP4020X Ā NCEUP4027X 4.50 Ā NCEUP4515X Ā NCEUP4520X Ā ā 5.00 Ā NCEUP5015X ā Ā ā -
OCTOPUS TISSUE STABILIZER
OctopusĀ
TissueĀ Stabilizers
OCTOPUS TISSUEĀ STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS ā THE NEXT GENERATION TISSUEĀ STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus⢠Evolution ā enhanced stability, flexibility, and a lower profile for unlimited positioning options ā the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximumĀ stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION ā LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizerĀ provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows ātoes upā position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 ā EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement
-
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS





Ā 




Reviews
There are no reviews yet.