TR BAND (REDICAL BAND)
Product Overview
TR Band is a compression device designed to assist haemostasis of the radial artery after a trans-radial procedure.
Radial hemostasis device used for Cardiac Cath or Interventional Radiology procedures.
Heparin 50 units/kg or less—band remains in place 60 minutes. Heparin (or comparable agent) greater than 50 units/kg —band remains in place for 120 minutes
The TR Band inflator syringe is filled with 18 cc of air and slowly injected into the one-way side port which inflates the balloon overlying the radial artery.
Apply the TR Band® Compression Device by aligning green marker, which is located on the center of the larger compression balloon (large) 1-2mm proximal to the puncture site, and fix the strap on the wrist with the adjustable fastener.
- TR Band is a compression device designed to assist haemostasis of the radial artery after a trans-radial procedure.
- Through the transparent structure designed for visual control and selective compression of the radial artery to allow blood return and preserve patency, TR Band assists in maintaining radial artery patency at the time of haemostasis in order to prevent future radial artery occlusion1,2
*1: Rathore S. et al., 2010. A Randomized Comparison of TR Band and Radistop Hemostatic Compression Devices After Trans-radial Coronary Intervention. Catheterization and Cardiovascular Interventions, 76(5), pp.660–667.*2: Pancholy et al., 2009. Impact of Two Different Hemostatic Devices on Radial Artery Outcomes after Trans-radial Catheterization. J. Invasive Cardiology, 21:101-104.
Features and Benefits

-
TransparencyEnsure continuous observation of access site.
-
Green markerEasy to apply the device to appropriate position.
-
Dual compression balloonsProvide precise compression to radial artery and avoid nerve compression. It can reduce pain for patient.
-
Syringe systemPermit accurate pressure adjustment.
-
Belt with magic tapeMake application fast and simple.
-
Support plateFits the wrist shape and fix the device construction.

Item Specifications
| size | Item Code | Length |
|---|---|---|
| Regular size | XX*RF06 | 24cm |
| Large size | XX*RF06L | 29cm |


Related products
-
EUPHORA SEMICOMPLIANT BALLOON CATHETER
Euphora™ semicompliant balloon
Balloon Dilatation Catheter
Euphora™ semicompliant balloon dilatation catheter complements your expertise and provides uncompromising performance in the moment you need it most.
OVERVIEW
Advancing Innovation through Partnership
To develop the Euphora™ low-profile semicompliant balloon dilatation catheter, we partnered with nearly 2,000 interventional cardiologists and cath lab professionals. The result is:
- Superior deliverability1
- Superb Kissing Balloons Technique (KBT) performance2
- The lowest crossing profile compared to leading competitors3
PRODUCT DETAILS
What Makes the Euphora Balloon an Excellent Choice?
ORDERING INFORMATION
BALLOON LENGTHS 6, 10, 12, AND 15 MM
1.50 EUP1506X EUP1510X EUP1512X EUP1515X 2.00 EUP2006X EUP2010X EUP2012X EUP2015X 2.25 EUP22506X EUP22510X EUP22512X EUP22515X 2.50 EUP2506X EUP2510X EUP2512X EUP2515X 2.75 EUP27506X EUP27510X EUP27512X EUP27515X 3.00 EUP3006X EUP3010X EUP3012X EUP3015X 3.25 EUP32506X EUP32510X EUP32512X EUP32515X 3.50 EUP3506X EUP3510X EUP3512X EUP3515X 3.75 EUP37506X EUP37510X EUP37512X EUP37515X 4.00 EUP4006X EUP4010X EUP4012X EUP4015X BALLOON LENGTHS 20, 25, AND 30 MM
1.50 EUP1520X — — 2.00 EUP2020X EUP2025X EUP2030X 2.25 EUP22520X EUP22525X — 2.50 EUP2520X EUP2525X EUP2530X 2.75 EUP27520X EUP27525X — 3.00 EUP3020X EUP3025X EUP3030X 3.25 EUP32520X EUP32525X — 3.50 EUP3520X EUP3525X EUP3530X 3.75 EUP37520X EUP37525X — 4.00 EUP4020X EUP4025X EUP4030X -
ACT CARTRIDGE (HR-ACT)
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
SKU:402-03Weight:3.00 LBSAvailability:2-3 Business daysShipping:Calculated at checkoutQuantity:Product Description
Medtronic 402-03 ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges, High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery, Box of 50
ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) – Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box 402-02 Recalcified Activated Clotting Time (RACT) – For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box 402-03 High Range Activated Clotting Time (HR ACT) – Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box 402-07 Heparinase Test Cartridge (HTC) – Fresh whole blood test used to identify the presence of heparin in the patient’s blood sample 20 per box -
FINECROSS Microcatheter
FINECROSS® MG Coronary Micro-Guide Catheter
Product Code Catheter Length Distal Hydrophilic Coating Distal Outer Diameter Proximal Outer Diameter Distal Inner Diameter Proximal Inner Diameter Recommended Guidewire Size 35-1430 130cm 70cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) 35-1450 150cm 90cm 1.8Fr. (0.60mm) 2.6 Fr. (0.87mm) 0.018″ (0.45mm) 0.021″ (0.55mm) 0.014″ (0.36mm) PRODUCT OVERVIEW
Coronary microguide catheter for integration of optimal guidewire support, superior trackability and crossability.1,2

TAPERED STAINLESS STEEL BRAID CONSTRUCTION FOR OPTIMAL GUIDEWIRE SUPPORT
FINECROSS MG stainless steel braid construction is designed to provide strength, responsiveness and support for improved pushability to access and cross complex lesions.
13cm FLOPPY DISTAL SEGMENT FOR SUPERIOR TRACKABILITY1
The distal 13 cm is ultra flexible for improved trackability around tight bends and tortuous anatomy.The floppy distal segment is designed to be atraumatic and provide an optimal balance between trackability and safety while navigating through the tortuous anatomy.1
TAPERED OUTER DIAMETER FOR SUPERIOR CROSSABILITY1,2
The outer diameter of the stainless steel shaft tapers from a proximal 2.6Fr. to a distal 1.8Fr. designed for improved crossability and guidewire handling.1,2
DOCUMENTS
-
OCTOPUS TISSUE STABILIZER
Octopus
Tissue Stabilizers
OCTOPUS TISSUE STABILIZERS
Our newest generation tissue stabilizer features automatic pod spread for effective visualization.
SUMMARY
OCTOPUS EVOLUTION AS – THE NEXT GENERATION TISSUE STABILIZER
The newest generation tissue stabiliser from Medtronic demonstrates an enduring commitment to the cardiac surgeon. With all the same features of the Octopus™ Evolution – enhanced stability, flexibility, and a lower profile for unlimited positioning options – the Octopus Evolution AS offers an automatic pod spread feature that enhances visibility at the anastomotic site.
- Automatic pod spread for effective visualisation of the anastomotic site
- Very secure arm for maximum stabilization
- Greater flexibility enables unlimited positioning options
- Simple, secure, one-handed attachment of clamp to the retractor
OCTOPUS EVOLUTION – LOW PROFILE WITH FLEXIBILITY AND REACH
The Octopus Evolution stabilizer provides enhanced stability, flexibility, and a lower profile for unlimited positioning options.
Enhanced stability and flexibility features:
- Improved visualisation with:
- Lower profile headlink
- Surgeon controlled pod-spread
- Allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications
- Increased flexibility and range of motion
- Longer, effective reach of the articulating arm provides easier access to all vessels
- Simple, secure, one-handed engagement of clamp and turret assembly
THE OCTOPUS 4.3 STABILISER FEATURES SUPERIOR ARM STRENGTH AND UNMATCHED STABILITY IN THE CLAMP/TURRET MECHANISM.
- Dual vacuum tubes offer superior tissue capture
- Internal cable enables arm twisting for maximum access and flexibility
- Reinforced arm links offer better stabilisation
- Whale tail tightens easily
- Swivel turret offers access while maximising visualisation
- Head lock design allows “toes up” position, pod spread and bend
- Rigid clamp designed to eliminate rocking
OCTOPUS 4 – EXCELLENT STABILITY AND FLEXIBILITY
The Octopus 4 tissue stabiliser includes innovative features, such as clear, malleable pods combined with a smaller diameter, more flexible arm, and an ultra-low headlink profile.
- Pod spreading optimises sewing space and stability of anastomotic site
- Reduced headlink profile improves visibility of surgical site
- Rigid, multi-material arm reduces movement at the anastomotic site
- Smaller diameter, more flexible arm offers greater flexibility in positioning
- Smaller, color-coded whale tail provides minimal obstruction
- Single vacuum tubing line minimises obstruction
- Innovative turret design increases effective arm reach, dramatically increasing positioning options with 360-degree movement









Reviews
There are no reviews yet.