PTCA BALLOON ACCUFORCE
Description
Force. Success. No Compromise.
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability. Accuforce is the latest generation of non-compliant PTCA balloons.
Characteristics
- Provides impressive high-pressure resistance up to 22 atm
- Optimizes (re)crossability and deliverability1
- Operates accurately in pre- and post-dilatation
General specifications
| Shaft diameter | 1.9 Fr / 0.64 mm Proximal 2.5 Fr / 0.84 mm Mid 2.6 Fr / 0.86 mm Distal |
|---|---|
| Usable length | 145 cm |
| Balloon markers | 2 |
| Nominal pressure | 12 atm / 1216 kPa |
| Rated burst pressure | 22 atm / 2229 kPa (2.0 mm to 4.0 mm) 20 atm / 2026 kPa (4.5 and 5.0 mm) |
| Guidewire compatibility | Maximum diameter 0.014″ / 0.36 mm |
| Lesion entry profile | 0.43 mm |
| Coating | Hydrophilic |
Item specifications
Ordering Information
| Balloon diameter (mm) |
Balloon length (mm) / Item references | ||||||
|---|---|---|---|---|---|---|---|
| 6 | 8 | 12 | 15 | 20 | 25 | 30 | |
| 2.00 | DC-RM2006HSW | DC-RM2008HSW | DC-RM2012HHW | DC-RM2015HHW | DC-RM2020HHW | — | — |
| 2.25 | DC-RM2206HSW | DC-RM2208HSW | DC-RM2212HHW | DC-RM2215HHW | DC-RM2220HHW | — | — |
| 2.50 | DC-RM2506HSW | DC-RM2508HSW | DC-RM2512HHW | DC-RM2515HHW | DC-RM2520HHW | DC-RM2525HHW | DC-RM2530HHW |
| 2.75 | DC-RM2706HSW | DC-RM2708HSW | DC-RM2712HHW | DC-RM2715HHW | DC-RM2720HHW | — | — |
| 3.00 | DC-RM3006HSW | DC-RM3008HSW | DC-RM3012HHW | DC-RM3015HHW | DC-RM3020HHW | DC-RM3025HHW | DC-RM3030HHW |
| 3.25 | DC-RM3206HSW | DC-RM3208HSW | DC-RM3212HHW | DC-RM3215HHW | DC-RM3220HHW | — | — |
| 3.50 | DC-RM3506HSW | DC-RM3508HSW | DC-RM3512HHW | DC-RM3515HHW | DC-RM3520HHW | DC-RM3525HHW | DC-RM3530HHW |
| 3.75 | DC-RM3706HSW | DC-RM3708HSW | DC-RM3712HHW | DC-RM3715HHW | DC-RM3720HHW | — | — |
| 4.00 | DC-RM4006HSW | DC-RM4008HSW | DC-RM4012HHW | DC-RM4015HHW | DC-RM4020HHW | — | — |
| 4.50 | DC-RM4506HSW | DC-RM4508HSW | DC-RM4512HSW | DC-RM4515HSW | — | — | — |
| 5.00 | DC-RM5006HSW | DC-RM5008HSW | DC-RM5012HSW | DC-RM5015HSW | — | — | — |
Please quote above item reference codes when placing an order.
Balloon Compliance
| Balloon diameter (mm) |
Pressure (atm) | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | |
| 2.00 | 1.58 | 1.65 | 1.72 | 1.79 | 1.84 | 1.88 | 1.92 | 1.95 | 1.98 | 2.00* | 2.01 | 2.03 | 2.04 | 2.05 | 2.06 | 2.08 | 2.09 | 2.10 | 2.12 | 2.13** | 2.14 | 2.15 | 2.17 |
| 2.25 | 1.96 | 2.01 | 2.06 | 2.11 | 2.14 | 2.16 | 2.19 | 2.21 | 2.23 | 2.25* | 2.26 | 2.28 | 2.29 | 2.31 | 2.32 | 2.34 | 2.35 | 2.36 | 2.38 | 2.39** | 2.41 | 2.42 | 2.44 |
| 2.50 | 2.19 | 2.24 | 2.30 | 2.36 | 2.38 | 2.41 | 2.44 | 2.46 | 2.48 | 2.50* | 2.52 | 2.53 | 2.55 | 2.56 | 2.58 | 2.60 | 2.61 | 2.63 | 2.64 | 2.66** | 2.68 | 2.69 | 2.71 |
| 2.75 | 2.43 | 2.48 | 2.53 | 2.59 | 2.62 | 2.65 | 2.67 | 2.70 | 2.73 | 2.75* | 2.77 | 2.79 | 2.80 | 2.82 | 2.84 | 2.86 | 2.87 | 2.89 | 2.91 | 2.93** | 2.94 | 2.96 | 2.98 |
| 3.00 | 2.65 | 2.71 | 2.76 | 2.82 | 2.85 | 2.89 | 2.92 | 2.95 | 2.97 | 3.00* | 3.02 | 3.04 | 3.06 | 3.08 | 3.10 | 3.11 | 3.13 | 3.15 | 3.17 | 3.19** | 3.21 | 3.23 | 3.25 |
| 3.25 | 2.89 | 2.95 | 3.01 | 3.07 | 3.10 | 3.14 | 3.17 | 3.20 | 3.22 | 3.25* | 3.27 | 3.29 | 3.31 | 3.33 | 3.35 | 3.37 | 3.39 | 3.42 | 3.44 | 3.46** | 3.47 | 3.48 | 3.51 |
| 3.50 | 3.13 | 3.19 | 3.26 | 3.32 | 3.35 | 3.39 | 3.42 | 3.45 | 3.47 | 3.50* | 3.52 | 3.54 | 3.57 | 3.59 | 3.61 | 3.63 | 3.65 | 3.68 | 3.70 | 3.72** | 3.74 | 3.74 | 3.76 |
| 3.75 | 3.37 | 3.44 | 3.50 | 3.56 | 3.60 | 3.63 | 3.66 | 3.69 | 3.72 | 3.75* | 3.77 | 3.80 | 3.82 | 3.84 | 3.86 | 3.88 | 3.90 | 3.92 | 3.94 | 3.96** | 3.98 | 3.99 | 4.01 |
| 4.00 | 3.58 | 3.65 | 3.72 | 3.79 | 3.83 | 3.87 | 3.90 | 3.94 | 3.97 | 4.00* | 4.03 | 4.05 | 4.07 | 4.09 | 4.11 | 4.13 | 4.15 | 4.17 | 4.19 | 4.21** | 4.23 | 4.26 | 4.28 |
| 4.50 | 4.02 | 4.10 | 4.19 | 4.28 | 4.32 | 4.37 | 4.40 | 4.44 | 4.47 | 4.50* | 4.53 | 4.56 | 4.59 | 4.63 | 4.66 | 4.68 | 4.71 | 4.75** | 4.78 | 4.81 | 4.84 | 4.87 | 4.91 |
| 5.00 | 4.52 | 4.59 | 4.67 | 4.75 | 4.80 | 4.85 | 4.89 | 4.93 | 4.96 | 5.00* | 5.03 | 5.07 | 5.10 | 5.13 | 5.16 | 5.19 | 5.22 | 5.26** | 5.29 | 5.32 | 5.35 | 5.38 | 5.41 |
** Rated burst pressure
References
1 Compared with Hiryu. Non-Compliant PTCA Balloon Catheter manufactured by Terumo Corporation.
Related products
-
PROGREAT® MICROCATHETHER
PRODUCT OVERVIEW
PROGREAT® Microcatheters are designed to allow navigation through tortuous peripheral vessels for optimal access and delivery of therapeutic embolization.
Terumo Progreat 2.7Fr. Microcatheter is Designed to provide optimal trackability and support even in the most tortuous anatomy.
DESIGNED TO CONFIDENTLY DELIVER EMBOLOTHERAPY
- Tungsten coil reinforcement for kink resistance2
- PTFE inner layer is designed for exceptional guidewire tracking, with virtually frictionless delivery of coils and other embolics2
- DMSO Compatible3
- Radiopaque 0.7 mm platinum/iridium markers allow for rapid and precise positioning4

DESIGNED TO ENHANCE ACCESS TO SMALL PERIPHERAL VESSELS
- TERUMO Glide TechnologyTM hydrophilic coating enhances navigation through tortuous anatomy1,2
- Unique varied tungsten coil pitch construction provides distal flexibility and proximal pushability, enhancing vessel selectivity and catheter placement.

PROGREAT® COAXIAL MICROCATHETER SYSTEM
- Preloaded with uniquely designed 0.021” GLIDEWIRE® GT for the 2.8Fr system and 0.018″ GLIDEWIRE® GT for the 2.4Fr system1
- Available in 2.8Fr and 2.4Fr
- Enables simultaneous preparation of microcatheter and guidewire, which may save time and increase procedural efficiency1
PROGREAT 2.4 COAXIAL PROVEN TO REACH DISTAL VESSELS WITH EASE⁴
- Provides greater vessel selectivity and demonstrated superiority in traversing tortuous anatomy
- Provides best-in-class kink resistance, demonstrated in both the distal and proximal shaft.

PROGREAT® Microcatheter Product Codes
Includes hemostatic valve and shaping mandrel
Fr Size Product Code Length (cm) Tip Shape Max Pressure (psi) RO Markers Hydrophilic Coating Length (cm) 2.4 MC*PB2411Y 110 Straight 750 1 50 MC*PB2413Y 130 Straight 1 70 MC*PB2413ZRA 130 70 Deg. Angle 1 70 MC*PB2413ZRC 130 J Curve 1 70 MC*PV2415Y 150 Straight 2 90 MC*PV2415ZRA 150 70 Deg. Angle 2 90 MC*PV2415ZRC 150 J Curve 2 90 2.7 MC*PC2711Y 110 Straight 750 – 50 MC*PC27137 130 Straight – 70 2.8 MC*PB2811Y 110 Straight 900 1 50 MC*PB2813Y 130 Straight 1 70 MC*PV2815Y 150 Straight 2 90 PROGREAT® Coaxial Microcatheter System Codes
Includes unique GLIDEWIRE® GT Guidewire, wire stopper, guidewire introducer, hemostatic valve, 2.5 mL syringe, and shaping mandrel
Fr Size Product
CodeLength
(cm)Max Pressure
(PSI)RO Markers Hydrophilic
Coating Length
(cm)Glidewire® GT
Length
(cm)Glidewire® GT Size
(in)2.4 Fr MC*PE24111YB 110 750 1 50 120 0.018 2.4 Fr MC*PE24131YB 130 750 1 70 140 0.018 2.4 Fr MC*PE24151YV 150 750 2 90 160 0.018 2.7 Fr MC*PE27111Y 110 750 – 50 120 0.021 2.7 Fr MC*PE27131Y 130 750 – 70 140 0.021 2.8 Fr MC*PE28111YB 110 900 1 50 120 0.021 2.8 Fr MC*PE28131YB 130 900 1 70 140 0.021 2.8 Fr MC*PE28151YV 150 900 2 90 160 0.021 PRODUCT SPECIFICATIONS
Catheter OD Length
(cm)Inner Diameter
(in/mm)Max GW
(in)Embolic
CompatibilityDead Space Volume
(mL)Actual Flow Rate* (mL/sec) @ 750 psi Actual Flow Rate* (mL/sec) @ 900 psi 2.4/2.9Fr
(0.80/0.97mm)110 0.022″/0.57 0.018″ 0.018″ Coils/HydroPearl®
600 ± 75 μm0.48 2.3 – 2.4/2.9Fr
(0.80/0.97mm)130 0.022″/0.57 0.018″ 0.018″ Coils/HydroPearl®
600 ± 75 μm0.53 2 – 2.4/2.9Fr
(0.80/0.97mm)150 0.022″/0.57 0.018″ 0.018″ Coils/HydroPearl®
600 ± 75 μm0.58 1.8 – 2.7/2.9Fr
(0.90/0.97mm)110 0.025″/0.065 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.57 3.5 – 2.7/2.9Fr
(0.90/0.97mm)130 0.025″/0.065 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.64 3.2 – 2.8/3.0Fr
(0.93/1.00mm)110 0.027″/0.70 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.61 4.1 4.7 2.8/3.0Fr
(0.93/1.00mm)130 0.027″/0.70 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.68 3.7 4.3 2.8/3.0Fr
(0.93/1.00mm)150 0.027″/0.70 0.021″ 0.018″ Coils/HydroPearl®
800 ± 75 μm0.75 3.1 3.9 REFERENCES
RX ONLY. Refer to the product labels and package insert for complete warnings, precautions, potential complications, and instructions for use.
- Catheter [Instructions for Use]. Somerset, NJ: Terumo Medical Corporation; 2016
- PROGREAT Catheter 510(k); 2003
- PROGREAT DMSO Compatibility Statement Letter
- Data on file.
-
GUIDING CATHETER EKARI
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Patients who have had cardiac catheterization or coronary angioplasty often are required to stay in bed with restricted movement for three to 24 hours afterward to prevent bleeding from the femoral artery catheter insertion site.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1

*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ekari Y, Nagaoka M, Kim JY, Merino Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Guide catheters are required for all coronary interventions to provide access to the coronary ostium and support equipment delivery. The ideal guide provides stability for device advancement through the coronary anatomy, while minimizing vessel trauma and allowing for vessel opacification.
The catheter is guided to the narrowed artery. Then, a smaller balloon catheter is inserted through the flexible catheter and inflated at the narrowed area to open it. Often, the doctor will also place a mesh coil called a stent at the narrowed part to help keep the artery open.
-
Launcher- 5f Guiding Catheter’s
EBU@ (Extra Backup)
LA5EBU30 (EBU 3.0)
LA5EBU35 (EBU 3.5)
LA5EBU375 (EBU 3.75)
LA5EBU40 (EBU 4.0)
LA5EBU45 (EBU 4.5)
LA5EBU50 (EBU 5.0)
JL@ (Judkin Left )
LA5JL30 (JL 3.0)
LA5JL35 (JL 3.5)
LA5JL40 (JL 4.0)
LA5JL45 (JL 4.5)
LA5JL50 (JL 5.0)
LA5JL60 (JL 6.0)
JR@ (Judkin Right )
LA5JR30 (JR 3.0)
LA5JR35 (JR 3.5)
LA5JR40 (JR 4.0)
LA5JR45 (JR 4.5)
LA5JR50 (JR 5.0)
LA5JR60 (JR 6.0)
AL@ (Amplatz Left )
LA5AL75 (AL .75)
LA5AL10 (AL 1.0)
LA5AL15 (AL 1.5)
LA5AL20 (AL 2.0)
LA5AL25 (AL 2.5)
LA5AL30 (AL 3.0)
LA5AL40 (AL 4.0)
SAL@ (Short Amplatz Left)
LA5SAL75 (SAL . 75)
LA5SAL10 (SAL 1.0)
LA5SAL15 (SAL 1.5)
LA5SAL20 (SAL 2.0)
LA5SAL25 (SAL 2.5)
LA5SAL30 (SAL 3.0)
LA5SAL40 (SAL 4.0)
AR@ (Amplatz Right)
LA5AR10 (AR 1.0)
LA5AR20 (AR 2.0)
LA5ALR12 (ALR 1.2)
ECR Curves@ (Backup Support Right)
LA5ECR35 (ECR 3.5)
LA5ECR40 (ECR 4.0)
LA5ECR45 (ECR 4.5)
LA5RBU35 (RBU 3.5)
LA5RBU40 (RBU 4.0)
SCR@ (Shepherd’s Crook Right)
LA5SCR35 (SCR 3.5)
LA5SCR40 (SCR 4.0)
LA5SCR50 (SCR 5.0)
SAR@ (Short Amplatz Right)
LA5SAR10 (SAR 1.0)
LA5SAR20 (SAR 2.0)
Multipurpose@
LA5MB1 (MB 1)
LA5MB2 (MB 2)
LA5HSREL (Hockey Stick)
LA5HSI (Hockey I)
LA5HSII (Hockey II)
LA5HSIII (Hockey III)
Bypass Crafts@
LA5LCB (LCB)
LA5RCB (RCB)
LA5RCB (RCB III)
LA5RCB (RCB 90cm)
LA5IMA (IMA)
LA5IMA (IMA 90cm)
-
GUIDING CATHETER HEARTRAIL
Product Overview
IMPROVED BACK UP SUPPORT*1
Catheter designed to use contralateral wall resulting in enhanced back-up support.
UNIVERSAL SHAPE (IKARI LEFT) *2
Offer capability of accessing the right and left coronary arteries, potentially avoiding catheter exchanges.
DESIGN FOR SAFETY
Soft tip to reduce damage to the vessel wall

*1: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*2: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.
Features and Benefits
Improved back up support in comparison to Terumo standard femoral guiding catheter shapes*1
*1: Based on comparative studies made among Terumo Guiding Catheters*2: Ikari Y, Nagaoka M, Kim JY, Moreno Y, Tanabe T. The physics of guiding catheters for the left coronary artery in transfemoral and trans-radial interventions. J Invasive Cardio. 2005 Dec; 17(12): 636-641.*3: Youssef AA, Hsieh YK, Cheng CI, We CJ. A single trans-radial guiding catheter for right and left coronary angiography and intervention. Euro intervention 2007; 3: 475-481.General Specifications
Sizes Available Item Code JL3.5/5F TCO06GC-F5JL350N JL3.5/6F TCO06GC-F6JL350N JL4.0/6F TCO06GC-F6JL400N JR3.5/5F TCO06GC-F5JR350N JR3.5/6F TCO06GC-F6JR350N JR4.0/5F TCO06GC-F5JR400N JR4.0/6F TCO06GC-F6JR400N JR4.0/7F TCO06GC-F7JR400N MULTIPURPOSE 6F TCO06GC-F6MP010N TR4.0/6F TCO06GC-F6TR400N Heartrail II is developed to maximize your back-up force when using right and left Ikari curves during transradial interventions and through its innovative 5-in-6 system.
Its high-strength wire braiding provides exceptional kink-resistance in tortuous blood vessels, while assuring superior torque response. It also has gentle tip and powerful shaft performance.









Reviews
There are no reviews yet.